Diagnosis of colorectal hepatic metastases: Comparison of contrast‐enhanced CT, contrast‐enhanced US, superparamagnetic iron oxide‐enhanced MRI, and gadoxetic acid‐enhanced MRI
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Purpose: To compare the diagnostic accuracy of contrast‐enhanced computed tomography (CE‐CT), contrast‐enhanced ultrasonography (CE‐US), superparamagnetic iron oxide‐enhanced magnetic resonance imaging (SPIO‐MRI), and gadoxetic acid‐enhanced MRI (Gd‐EOB‐MRI) in the evaluation of colorectal hepatic metastases. Materials and Methods: In all, 111 patients with colorectal cancers were enrolled in this study. Of the 112 metastases identified in 46 patients, 31 in 18 patients were confirmed histologically and the remaining 81 in 28 patients were confirmed by follow‐up imaging. CE‐CT, CE‐US, SPIO‐MRI, and Gd‐EOB‐MRI were evaluated. Mean (of three readers, except for CE‐US) area under the receiver operating characteristic curve (A z), sensitivities, and positive predictive values (PPV) were calculated. Each value was compared to the others by variance z‐test or chi‐square test with Bonferroni correction. Results: For all lesions, mean A z and sensitivity of Gd‐EOB‐MRI (0.992, 95% [56/59]) were significantly greater than those of CE‐CT (0.847, 63% [71/112]) and CE‐US (0.844, 73% [77/106]). For lesions ≤1 cm, mean A z and sensitivity of Gd‐EOB‐MRI (0.999, 92% [22/24]) were significantly greater than those of CE‐CT (0.685, 26% [13/50]) and CE‐US (0.7, 41% [18/44]). Mean A z (95% CI) of SPIO‐MRI for all lesions (0.966 [0.929–0.987]) and lesions ≤ 1 cm (0.961 [0.911–0.988]) were significantly greater than those of CE‐CT and CE‐US. Mean sensitivity of SPIO‐MRI for lesions ≤1 cm (63%, 26/41) was significantly greater than that of CE‐CT. Conclusion: Gd‐EOB‐MRI and SPIO‐MRI were more accurate than CE‐CT and CE‐US for evaluation of liver metastasis in patients with colorectal carcinoma. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ethical principles for medical research involving human subjects
(2003) · Manual for Research Ethics Committees · doi:10.1017/cbo9780511550089.027 · Cited by 2,585
Niekel, M. C., Bipat, S., & Stoker, J. (2010) · Radiology · doi:10.1148/radiol.10100729 · Cited by 584
Hamm, B., Staks, T., Mühler, A., Bollow, M., Taupitz, M., Frenzel, T., Wolf, K. J., Weinmann, H. J., & Lange, L. (1995) · Radiology · doi:10.1148/radiology.195.3.7754011 · Cited by 575
Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA.
Vogl, T. J., Kümmel, S., Hammerstingl, R., Schellenbeck, M., Schumacher, G., Balzer, T., Schwarz, W., Müller, P. K., Bechstein, W. O., Mack, M. G., et al. (1996) · Radiology · doi:10.1148/radiology.200.1.8657946 · Cited by 453
Ethical principles for medical research involving human subjects
(2009) · Anales del Sistema Sanitario de Navarra · doi:10.23938/assn.0522 · Cited by 398
Huppertz, A., Haraida, S., Kraus, A., Zech, C. J., Scheidler, J., Breuer, J., Helmberger, T. K., & Reiser, M. F. (2005) · Radiology · doi:10.1148/radiol.2342040278 · Cited by 370
Phagocytosis of ultrasound contrast agent microbubbles by Kupffer cells
Yanagisawa, K., Moriyasu, F., Miyahara, T., Yuki, M., & Iijima, H. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.08.008 · Cited by 343 · cited 1×
“Contrast-enhanced ultrasonography (CE-US) using Sonazoid enables both dynamic and hepatic parenchymal (Kupffer) phase imaging due to accumulation of microbubbles in the reticuloendothelial cells (12,13).”
MethodSenéterre, E., Taourel, P., Bouvier, Y., Pradel, J., Van Beers, B., Daures, J. P., Pringot, J., Mathieu, D., & Bruel, J. M. (1996) · Radiology · doi:10.1148/radiology.200.3.8756932 · Cited by 310
Phase II clinical evaluation of Gd-EOB-DTPA: dose, safety aspects, and pulse sequence.
Reimer, P., Rummeny, E. J., Shamsi, K., Balzer, T., Daldrup, H. E., Tombach, B., Hesse, T., Berns, T., & Peters, P. E. (1996) · Radiology · doi:10.1148/radiology.199.1.8633143 · Cited by 309
Neuwelt, E. A., Hamilton, B. E., Varallyay, C. G., Rooney, W. R., Edelman, R. D., Jacobs, P. M., & Watnick, S. G. (2009) · Kidney International · doi:10.1038/ki.2008.496 · Cited by 267
Hagspiel, K. D., Neidl, K. F., Eichenberger, A. C., Weder, W., & Marincek, B. (1995) · Radiology · doi:10.1148/radiology.196.2.7617863 · Cited by 254
Colorectal metastasis (liver and lung)
Penna, C., & Nordlinger, B. (2002) · Surgical Clinics of North America · doi:10.1016/s0039-6109(02)00051-8 · Cited by 217
Halavaara, J., Breuer, J., Ayuso, C., Balzer, T., Bellin, M.-F., Blomqvist, L., Carter, R., Grazioli, L., Hammerstingl, R., Huppertz, A., et al. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200605000-00001 · Cited by 174
Quaia, E., D’Onofrio, M., Palumbo, A., Rossi, S., Bruni, S., & Cova, M. A. (2006) · European Radiology · doi:10.1007/s00330-006-0192-7 · Cited by 157
Hatanaka, K., Kudo, M., Minami, Y., 上田, 泰., Tatsumi, C., Kitai, S., Takahashi, S., Inoue, T., Hagiwara, S., Chung, H., et al. (2008) · Intervirology · doi:10.1159/000122600 · Cited by 151
Fretz, C. J., Stark, D. D., Metz, C. E., Elizondo, G., Weissleder, R., Shen, J.-H., WITTENBERG, J., Simeone, J. F., & Ferrucci, J. T. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.4.2119106 · Cited by 90
Kim, Y. K., Lee, J. M., Kim, C. S., Chung, G. H., Kim, C. Y., & Kim, I. H. (2004) · European Radiology · doi:10.1007/s00330-004-2570-3 · Cited by 88
Frate, C. D., Bazzocchi, M., Mortelé, K. J., Zuiani, C., Londero, V., Como, G., Zanardi, R., & Ros, P. R. (2002) · Radiology · doi:10.1148/radiol.2253011854 · Cited by 84
Onishi, H., Murakami, T., Kim, T., Hori, M., Iannaccone, R., Kuwabara, M., Abe, H., Nakata, S., Osuga, K., Tomoda, K., et al. (2006) · Radiology · doi:10.1148/radiol.2383041825 · Cited by 77
Comparison of Gd‐EOB‐DTPA and Gd‐DTPA for contrast‐enhanced MR imaging of liver tumors
Clémеnt, O., Mühler, A., Vexler, V. S., et al. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030113 · Cited by 50
Kim, Y. K., Lee, Y. H., Kwak, H. S., Kim, C. S., & Han, Y. M. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.09.027 · Cited by 42 · cited 2×
“Similarly Kim et al (30) reported slightly better diagnostic accuracy with Gd-EOB-MRI (93.8% and 92.5”
BackgroundInfluentialKim, M., Kim, J. H., Lim, J. S., Oh, Y. T., Chung, J. B., Choi, J. S., Lee, W. J., & Kim, K. W. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20174 · Cited by 34
Sugimoto, K., Shiraishi, J., Moriyasu, F., Saito, K., & Doi, K. (2009) · Academic Radiology · doi:10.1016/j.acra.2008.12.025 · Cited by 34
Kim, H. J., Kim, K. W., Byun, J. H., Won, H. J., Shin, Y. M., Kim, P. N., Lee, M.-S., & Lee, M.-G. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1941 · Cited by 30
Detection of hepatic metastasis: manganese-and ferucarbotran-enhanced MR imaging
Choi, J.-Y., Kim, M.-J., Kim, J. H., Kim, S. H., Ko, H.-K., Lim, J. S., Oh, Y. T., Chung, J.-J., Yoo, H. S., Lee, J. T., et al. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.016 · Cited by 29
Motosugi, U., Ichikawa, T., Nakajima, H., Sou, H., Sano, M., Sano, K., Araki, T., Iino, H., Fujii, H., & Nakazawa, T. (2009) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e31817f5c82 · Cited by 27
Self-citationMuhi, A., Ichikawa, T., Motosugi, U., Sou, H., Nakajima, H., Sano, K., Kitamura, T., Fatima, Z., Fukushima, K., Araki, T., et al. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22360 · Cited by 23
Self-citationFrate, C. D., Zuiani, C., Londero, V., et al. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.5.1801339 · Cited by 16
Cited by
Dietrich, C. F., Nolsøe, C. P., Barr, R. G., Berzigotti, A., Burns, P. N., Cantisani, V., Chammas, M. C., Chaubal, N., Choi, B. I., Clevert, D.-A., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.04.030 · Cited by 498
Time to Progression of Pancreatic Cancer: Evaluation with Multi-Detector Computed Tomography
Ahn, S. J., Choi, S. J., & Kim, H. S. (2017) · Journal of Gastrointestinal Cancer · doi:10.1007/s12029-016-9876-7 · Cited by 32
Metadata
- Authors
- Muhi, A., Ichikawa, T., Motosugi, U., Sou, H., Nakajima, H., Sano, K., Sano, M., Kato, S., Kitamura, T., Fatima, Z., Fukushima, K., Iino, H., Mori, Y., Fujii, H., & Araki, T.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2011-07-20
- Volume
- 34
- Issue
- 2
- Pages
- 326-335
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1978213619
- Cited by
- 168
- References
- 28
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.