CoChat

Diagnosis of colorectal hepatic metastases: Comparison of contrast‐enhanced CT, contrast‐enhanced US, superparamagnetic iron oxide‐enhanced MRI, and gadoxetic acid‐enhanced MRI

Open access
Muhi, Ali, Ichikawa, Tomoaki, Motosugi, Utaroh, Sou, Hironobu, Nakajima, Hiroto, Sano, Katsuhiro, Sano, Mika, Kato, Satoshi, Kitamura, Takatoshi, Fatima, Zareen, Fukushima, Kimiyo, Iino, Hiroshi, Mori, Yoshiyuki, Fujii, Hideki, Araki, Tsutomu · 2011 · Journal of Magnetic Resonance Imaging
Cited by 168

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Purpose: To compare the diagnostic accuracy of contrast‐enhanced computed tomography (CE‐CT), contrast‐enhanced ultrasonography (CE‐US), superparamagnetic iron oxide‐enhanced magnetic resonance imaging (SPIO‐MRI), and gadoxetic acid‐enhanced MRI (Gd‐EOB‐MRI) in the evaluation of colorectal hepatic metastases. Materials and Methods: In all, 111 patients with colorectal cancers were enrolled in this study. Of the 112 metastases identified in 46 patients, 31 in 18 patients were confirmed histologically and the remaining 81 in 28 patients were confirmed by follow‐up imaging. CE‐CT, CE‐US, SPIO‐MRI, and Gd‐EOB‐MRI were evaluated. Mean (of three readers, except for CE‐US) area under the receiver operating characteristic curve (A z), sensitivities, and positive predictive values (PPV) were calculated. Each value was compared to the others by variance z‐test or chi‐square test with Bonferroni correction. Results: For all lesions, mean A z and sensitivity of Gd‐EOB‐MRI (0.992, 95% [56/59]) were significantly greater than those of CE‐CT (0.847, 63% [71/112]) and CE‐US (0.844, 73% [77/106]). For lesions ≤1 cm, mean A z and sensitivity of Gd‐EOB‐MRI (0.999, 92% [22/24]) were significantly greater than those of CE‐CT (0.685, 26% [13/50]) and CE‐US (0.7, 41% [18/44]). Mean A z (95% CI) of SPIO‐MRI for all lesions (0.966 [0.929–0.987]) and lesions ≤ 1 cm (0.961 [0.911–0.988]) were significantly greater than those of CE‐CT and CE‐US. Mean sensitivity of SPIO‐MRI for lesions ≤1 cm (63%, 26/41) was significantly greater than that of CE‐CT. Conclusion: Gd‐EOB‐MRI and SPIO‐MRI were more accurate than CE‐CT and CE‐US for evaluation of liver metastasis in patients with colorectal carcinoma. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22613

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 168

Metadata

Authors
Muhi, A., Ichikawa, T., Motosugi, U., Sou, H., Nakajima, H., Sano, K., Sano, M., Kato, S., Kitamura, T., Fatima, Z., Fukushima, K., Iino, H., Mori, Y., Fujii, H., & Araki, T.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2011-07-20
Volume
34
Issue
2
Pages
326-335
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1978213619
Cited by
168
References
28
FWCI
10.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.