The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
UTE imaging in the musculoskeletal system
Open accessAbstract
Tissues, such as bone, tendon, and ligaments, contain a high fraction of components with "short" and "ultrashort" transverse relaxation times and therefore have short mean transverse relaxation times. With conventional magnetic resonance imaging (MRI) sequences that employ relatively long echo times (TEs), there is no opportunity to encode the decaying signal of short and ultrashort T2/T2* tissues before it has reached zero or near zero. The clinically compatible ultrashort TE (UTE) sequence has been increasingly used to study the musculoskeletal system. This article reviews the UTE sequence as well as various modifications that have been implemented since its introduction. These modifications have been used to improve efficiency or contrast as well as provide quantitative analysis. This article reviews several clinical musculoskeletal applications of UTE. J. Magn. Reson. Imaging 2015;41:870–883. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Basic Science of Articular Cartilage: Structure, Composition, and Function
Sophia Fox, A. J., Bedi, A., & Rodeo, S. A. (2009) · Sports Health: A Multidisciplinary Approach · doi:10.1177/1941738109350438 · Cited by 2,774
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Microvasculature of the human meniscus
Arnoczky, S. P., & Warren, R. F. (1982) · The American Journal of Sports Medicine · doi:10.1177/036354658201000205 · Cited by 1,239
Structure of the tendon connective tissue
Kannus, P. (2000) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2000.010006312.x · Cited by 1,148
Martin, R. B., Burr, D. B., & Sharkey, N. A. (1998) · Springer eBooks · doi:10.1007/978-1-4757-2968-9 · Cited by 976
Joint Structure and Function: A Comprehensive Analysis
Levangie, P. K., & Norkin, C. C. (2006) · Medical Entomology and Zoology · Cited by 868
Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200311000-00001 · Cited by 717
Tendons and ligaments: A morphological and biochemical comparison
Amiel, D., Frank, C., Harwood, F., Fronek, J., & Akeson, W. (1983) · Journal of Orthopaedic Research · doi:10.1002/jor.1100010305 · Cited by 607
Immunohistochemical localization of short chain cartilage collagen (type X) in avian tissues.
Schmid, T. M., & Linsenmayer, T. F. (1985) · The Journal of cell biology · doi:10.1083/jcb.100.2.598 · Cited by 447
Collagenous fibril texture of the human knee joint menisci
Petersen, W., & Tillmann, B. (1998) · Anatomy and Embryology · doi:10.1007/s004290050141 · Cited by 427
Roberts, S., Urban, J. P. G., Evans, H., & Eisenstein, S. M. (1996) · Spine · doi:10.1097/00007632-199602150-00003 · Cited by 388
Riley, G. P., Harrall, R. L., Constant, C. R., Chard, M. D., Cawston, T. E., & Hazleman, B. L. (1994) · Annals of the Rheumatic Diseases · doi:10.1136/ard.53.6.359 · Cited by 385
Brent, B. (1981) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198101000-00023 · Cited by 339
Design and analysis of a practical 3D cones trajectory
Gurney, P. T., Hargreaves, B. A., & Nishimura, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20796 · Cited by 335
TMJ Disorders: Future Innovations in Diagnostics and Therapeutics
Wadhwa, S., & Kapila, S. (2008) · Journal of Dental Education · doi:10.1002/j.0022-0337.2008.72.8.tb04569.x · Cited by 297
Clinical anatomy of the lumbar spine and sacrum
Wallner-Schlotfeldt, T. (2000) · South African Journal of Physiotherapy · doi:10.4102/sajp.v56i3.542 · Cited by 285
Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling
Rahmer, J., Börnert, P., Groen, J., & Bos, C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20868 · Cited by 273
The Enthesis Organ Concept and Its Relevance to the Spondyloarthropathies
Benjamin, M., & McGonagle, D. (2009) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4419-0298-6_4 · Cited by 256
Orientation of tendons in the magnetic field and its effect on T2 relaxation times.
Fullerton, G. D., Cameron, I. L., & Ord, V. A. (1985) · Radiology · doi:10.1148/radiology.155.2.3983395 · Cited by 250
Cortical Bone Water: In Vivo Quantification with Ultrashort Echo-Time MR Imaging
Techawiboonwong, A., Song, H. K., Leonard, M. B., & Wehrli, F. W. (2008) · Radiology · doi:10.1148/radiol.2482071995 · Cited by 222
Quantitative MRI for the assessment of bone structure and function
Wehrli, F. W., Song, H. K., Saha, P. K., & Wright, A. C. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1066 · Cited by 207
Assessing degeneration of human articular cartilage with ultra-short echo time (UTE) T2* mapping
Williams, A., Qian, Y., Bear, D., & Chu, C. R. (2010) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2010.02.001 · Cited by 161
Qualitative and quantitative ultrashort‐TE MRI of cortical bone
Du, J., & Bydder, G. M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2906 · Cited by 159
Self-citationAchilles Tendinosis: Changes in Biochemical Composition and Collagen Turnover Rate
de Mos, M., van El, B., DeGroot, J., Jahr, H., van Schie, H. T. M., van Arkel, E. R., Tol, H., Heijboer, R., van Osch, G. J. V. M., & Verhaar, J. A. N. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546507301885 · Cited by 158
Short T2 contrast with three-dimensional ultrashort echo time imaging
Du, J., Bydder, M., Takahashi, A., Carl, M., Chung, C. B., & Bydder, G. M. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.11.003 · Cited by 154
Self-citationAspden, R. M., & Hukins, D. W. L. (1981) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1981.0040 · Cited by 130
Wu, Y., Ackerman, J. L., Chesler, D. A., Graham, L., Wang, Y., & Glimcher, M. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10512 · Cited by 129
Horch, R. A., Gochberg, D. F., Nyman, J. S., & Does, M. D. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016359 · Cited by 123
Glycosaminoglycans and proteoglycans from different zones of the porcine knee meniscus
Nakano, T., Dodd, C. M., & Scott, P. G. (1997) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100150209 · Cited by 113
Fernández‐Seara, M. A., Wehrli, S. L., Takahashi, M., & Wehrli, F. W. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.0301227 · Cited by 108
Ultrashort TE T1rho (UTE T1rho) imaging of the Achilles tendon and meniscus
Du, J., Carl, M., Diaz, E. S., Takahashi, A., Han, E. T., Szeverenyi, N. M., Chung, C. B., & Bydder, G. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22474 · Cited by 107
Self-citationDu, J., Takahashi, A., Bae, W. C., Chung, C. B., & Bydder, G. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22257 · Cited by 102
Self-citationMacromolecule and water magnetization exchange modeling in articular cartilage
Lattanzio, P., Marshall, K. W., Damyanovich, A. Z., & Peemoeller, H. (2000) · Magnetic Resonance in Medicine · Cited by 89
Du, J., Carl, M., Bae, W. C., Statum, S. M., Chang, E. Y., Bydder, G. M., & Chung, C. B. (2012) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2012.09.009 · Cited by 88
Self-citationUTE-T2∗ mapping of human articular cartilage in vivo: a repeatability assessment
Williams, A. A., Qian, Y., & Chu, C. R. (2010) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2010.10.018 · Cited by 86
Cortical Bone Water Concentration: Dependence of MR Imaging Measures on Age and Pore Volume Fraction
Li, C., Seifert, A. C., Rad, H. S., Bhagat, Y. A., Rajapakse, C. S., Sun, W., Lam, S. C. B., & Wehrli, F. W. (2014) · Radiology · doi:10.1148/radiol.14132585 · Cited by 83
Ultrashort TE imaging with off‐resonance saturation contrast (UTE‐OSC)
Du, J., Takahashi, A., Bydder, M., Chung, C. B., & Bydder, G. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22007 · Cited by 58
Self-citationWang, N., & Xia, Y. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24012 · Cited by 48
Muir, H. (1978) · Journal of Clinical Pathology · doi:10.1136/jcp.31.suppl_12.67 · Cited by 41
Bin, K., Dai, J., Wang, Q., Song, R., Jiao, K., Zhang, J., Tian, X.-G., Duan, Y., & Wang, M. (2012) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2012.08.024 · Cited by 32
Wang, K., Yu, H., Brittain, J. H., Reeder, S. B., & Du, J. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22121 · Cited by 28
Self-citationMuir, H. M. (1978) · Journal of Clinical Pathology · doi:10.1136/jcp.s3-12.1.67 · Cited by 9
Research works printed but not linked: 55
- 10.1259/bjr/74368403 · doi:10.1259/bjr/74368403
- Pauly JM, 2012, Selective excitation for ultrashort echo time imaging. eMagRes
- 10.1016/j.mri.2007.08.005 · doi:10.1016/j.mri.2007.08.005
- 10.1002/mrm.21620 · doi:10.1002/mrm.21620
- 10.1002/mrm.1910390212 · doi:10.1002/mrm.1910390212
- Weiger M, 2012, MRI with zero echo time. eMagRes
- 10.1002/9780470034590.emrstm1259 · doi:10.1002/9780470034590.emrstm1259
- 10.1002/mrm.23017 · doi:10.1002/mrm.23017
- Ida M, 2014, Quiet T1‐weighted imaging using PETRA: initial clinical evaluation in intracranial tumor patients, J Magn Reson Imaging
- 10.1016/j.jmr.2010.09.013 · doi:10.1016/j.jmr.2010.09.013
- 10.1002/mrm.23075 · doi:10.1002/mrm.23075
- Gore JC, 2013, The physics of relaxation. eMagRes
- Du J, 2012, Quantitative ultrashort TE (UTE) imaging of short T2 tissues. eMagRes
- 10.1002/jmri.21396 · doi:10.1002/jmri.21396
- 10.1302/2046-3758.21.2000135 · doi:10.1302/2046-3758.21.2000135
- 10.1002/mrm.23047 · doi:10.1002/mrm.23047
- 10.1148/radiol.12111883 · doi:10.1148/radiol.12111883
- 10.1097/RLI.0b013e31821c44cd · doi:10.1097/rli.0b013e31821c44cd
- 10.1002/mrm.24130 · doi:10.1002/mrm.24130
- 10.1097/00004728-198511000-00002 · doi:10.1097/00004728-198511000-00002
- Springer F, 2012, Magnetization transfer‐ultrashort echo time (MT‐UTE) imaging. eMagRes
- Johnson D, 2007, Practical orthopaedic sports medicine and arthroscopy
- 10.1002/(SICI)1097-0029(19970515)37:4<271::AID-JEMT3>3.0.CO;2-O · doi:10.1002/(sici)1097-0029(19970515)37:4<271::aid-jemt3>3.0.co;2-o
- 10.1016/j.joca.2013.04.021 · doi:10.1016/j.joca.2013.04.021
- 10.1302/0301-620X.62B3.7410471 · doi:10.1302/0301-620x.62b3.7410471
- 10.22203/eCM.v021a35 · doi:10.22203/ecm.v021a35
- 10.1148/radiol.09081743 · doi:10.1148/radiol.09081743
- 10.1002/1522-2594(200012)44:6<840::AID-MRM4>3.0.CO;2-K · doi:10.1002/1522-2594(200012)44:6<840::aid-mrm4>3.0.co;2-k
- 10.1002/mrm.22450 · doi:10.1002/mrm.22450
- 10.1002/jmri.10432 · doi:10.1002/jmri.10432
- 10.1111/joa.12133 · doi:10.1111/joa.12133
- 10.1007/s003300050547 · doi:10.1007/s003300050547
- 10.1002/mrm.24186 · doi:10.1002/mrm.24186
- 10.1016/j.bone.2013.01.027 · doi:10.1016/j.bone.2013.01.027
- 10.1002/nbm.1631 · doi:10.1002/nbm.1631
- Blain E, 2011, Sports injuries, 45
- 10.1016/j.orthres.2004.06.016 · doi:10.1016/j.orthres.2004.06.016
- 10.1002/jor.1100120205 · doi:10.1002/jor.1100120205
- 10.1148/radiol.12111439 · doi:10.1148/radiol.12111439
- 10.1016/j.joca.2012.01.009 · doi:10.1016/j.joca.2012.01.009
- 10.1016/j.jbiomech.2010.01.020 · doi:10.1016/j.jbiomech.2010.01.020
- 10.1007/s00256-013-1738-9 · doi:10.1007/s00256-013-1738-9
- 10.1002/jmri.22810 · doi:10.1002/jmri.22810
- Sanal HT, 2011, Magnetic resonance imaging of the temporomandibular joint disc: feasibility of novel quantitative magnetic resonance evaluation using histologic and biomechanical reference standards, J Orofac Pain, 25, 345
- 10.3109/03008200903349639 · doi:10.3109/03008200903349639
- 10.1136/ard.2003.019182 · doi:10.1136/ard.2003.019182
- 10.1111/j.1600-0838.1997.tb00124.x · doi:10.1111/j.1600-0838.1997.tb00124.x
- 10.1016/j.crad.2007.12.010 · doi:10.1016/j.crad.2007.12.010
- 10.1016/S0006-3495(90)82508-X · doi:10.1016/s0006-3495(90)82508-x
- 10.1007/s00330-013-2897-8 · doi:10.1007/s00330-013-2897-8
- 10.3109/03008208909103905 · doi:10.3109/03008208909103905
- 10.1002/(SICI)1522-2594(200001)43:1<34::AID-MRM5>3.0.CO;2-7 · doi:10.1002/(sici)1522-2594(200001)43:1<34::aid-mrm5>3.0.co;2-7
- 10.1148/radiol.12121181 · doi:10.1148/radiol.12121181
- 10.1002/mrm.1910340502 · doi:10.1002/mrm.1910340502
- 10.1016/j.ejrad.2013.10.014 · doi:10.1016/j.ejrad.2013.10.014
Cited by
MRI assessment of bone structure and microarchitecture
Chang, G., Boone, S., Martel, D., Rajapakse, C. S., Hallyburton, R. S., Valko, M., Honig, S., & Regatte, R. R. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25647 · Cited by 151
Metadata
- Authors
- Chang, E. Y., Du, J., & Chung, C. B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2014-07-16
- Volume
- 41
- Issue
- 4
- Pages
- 870-883
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1835090478
- Cited by
- 276
- References
- 42
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- green
- Funders
- VA Clinical Science Research and Development Service (Career Development Grant 1IK2CX000749 and Merit Award I01CX000625)
- National Institutes of Health (NIH) (R01DE022068 and R21 AR063894)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.