Cited by 19Maternal and fetal healthcareMedical Image Segmentation TechniquesArtificial Intelligence in Healthcare and Education

A Deep Learning Pipeline Using Prior Knowledge for Automatic Evaluation of Placenta Accreta Spectrum Disorders With MRI

Open access
Wang, Haijie, Wang, Yida, Zhang, He, Yin, Xuan, Wang, Chenglong, Lu, Yuanyuan, Song, Yang, Zhu, Hao +1 more·2024·Journal of Magnetic Resonance Imaging

Abstract

Background: The diagnosis of prenatal placenta accreta spectrum (PAS) with magnetic resonance imaging (MRI) is highly dependent on radiologists' experience. A deep learning (DL) method using the prior knowledge that PAS‐related signs are generally found along the utero‐placental borderline (UPB) may help radiologists, especially those with less experience, to mitigate this issue. Purpose: To develop a DL tool for antenatal diagnosis of PAS using T2‐weighted MR images. Study Type: Retrospective. Subjects: Five hundred and forty pregnant women with clinically suspected PAS disorders from two institutions, divided into training (409), internal test (103), and external test (28) datasets. Field Strength/Sequence: Sagittal T2‐weighted fast spin echo sequence at 1.5 T and 3 T. Assessment: An nnU‐Net was trained for placenta segmentation. The UPB straightening approach was used to extract the utero‐placental boundary region. The UPB image was then fed into DenseNet‐PAS for PAS diagnosis. DenseNet‐PP learnt placental position information to improve the PAS diagnosis performance. Three radiologists with 8, 10, and 12 years of experience independently evaluated the images. Two radiologists marked the placenta tissue. Histopathological findings were the reference standard. Statistical Tests: Area under the curve (AUC) was used to evaluate the classification. Dice coefficient evaluated the segmentation between radiologists and the model performance. The Mann–Whitney U‐test or the chi‐squared test assessed the significance of differences. Decision curve analysis was used to determine clinical effectiveness. DeLong's test was used to compare AUCs. Results: Of the 540 patients, 170 had PAS disorders confirmed by histopathology. The DL model using UPB images and placental position yielded the highest AUC of 0.860 and 0.897 in internal test and external test cohorts, respectively, significantly exceeding the performance of three radiologists (internal test AUC, 0.737–0.770). Data Conclusion: By extracting the UPB image, this fully automatic DL pipeline achieved high accuracy and may assist radiologists in PAS diagnosis using MRI. Level of Evidence: 3 Technical Efficacy: Stage 2

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.28770

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wang et al. concluded that ML provided more consistent diagnostic accuracy, reducing variability caused by differing levels of radiological expertise for PAS diagnosis.

    “The study concluded that ML provided more consistent diagnostic accuracy, reducing variability caused by differing levels of radiological expertise.”

    From Machine Learning in Maternity: Early Diagnosis of Placenta Accreta Spectrum (2026) · cites this paper as [31]

    The Discussion (page not provided) says radiologists’ PAS interpretations vary with expertise and proposes the DL tool to homogenize diagnosis across regions. The paper reports strong model performance, but it does not establish that using the tool actually reduced variability in diagnostic accuracy across radiologists with different expertise. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • In a 2024 retrospective study, Wang et al. found that their ML program outperformed radiologists in diagnosing PAS, with an AUC of 0.860 vs. 0.737/0.749/0.770.

    “They discovered that the ML program outperformed the radiologists, with an area under the curve (AUC) of 0.860 vs. 0.737/0.749/0.770, respectively.”
  • Wang et al. concluded that their program could normalize the varying levels of manual diagnostic PAS expertise through the minimization of PAS diagnosis to their one ML program.

    “Wang et al. [31] concluded that their program could normalize the varying levels of manual diagnostic PAS expertise through the minimization of PAS diagnosis to their one ML program.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

1 retracted

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wang, H., Wang, Y., Zhang, H., Yin, X., Wang, C., Lu, Y., Song, Y., Zhu, H., & Yang, G.
Affiliations
  • East China Normal University (CN)
  • Shanghai Medical College of Fudan University (CN)
  • Tongji University (CN)
  • Siemens (China) (CN)
Corresponding author
  • Zhu, Hao
  • Yang, Guang
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2023-05-13
Volume
59
Issue
2
Pages
483-493
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W4376504590
Cited by
19
References
41
Citations by year
2026: 8 · 2025: 4 · 2024: 5 · 2023: 2
FWCI
7.00
Type
journal article
Language
en
Open access
Locations
  • Journal of Magnetic Resonance Imaging (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Natural Science Foundation of China (61731009)
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and fetal healthcare
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
placenta accreta spectrum, prenatal diagnosis, placenta segmentation, placental location, T2-weighted MRI, nnU-Net, DenseNet, radiologist experience, automated diagnosis
MeSH terms
Deep Learning, Female, Humans, Magnetic Resonance Imaging, Placenta, Placenta Accreta, Pregnancy, Retrospective Studies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review