Respiratory virus RNA is detectable in airborne and droplet particles
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Aerosol transmission routes of respiratory viruses have been classified by the WHO on the basis of equilibrium particle size. Droplet transmission is associated with particles sized >5 µm in diameter and airborne transmission is associated with particles sized ≤5 µm in diameter. Current infection control measures for respiratory viruses are directed at preventing droplet transmission, although epidemiological evidence suggests concurrent airborne transmission also occurs. Understanding the size of particles carrying viruses can be used to inform infection control procedures and therefore reduce virus transmission. This study determined the size of particles carrying respiratory viral RNA produced on coughing and breathing by 12 adults and 41 children with symptomatic respiratory infections. A modified six‐stage Andersen Sampler collected expelled particles. Each stage was washed to recover samples for viral RNA extraction. Influenza A and B, parainfluenza 1, 2 and 3, respiratory syncytial virus (RSV), human metapneumovirus and human rhinoviruses (hRV) were detected using RT‐PCR. On breathing, 58% of participants produced large particles (>5 µm) containing viral RNA and 80% produced small particles (≤5 µm) carrying viral RNA. On coughing, 57% of participants produced large particles containing viral RNA and 82% produced small particles containing viral RNA. Forty five percent of participants produced samples positive for hRV viral RNA and 26% of participants produced samples positive for viral RNA from parainfluenza viruses. This study demonstrates that individuals with symptomatic respiratory viral infections produce both large and small particles carrying viral RNA on coughing and breathing. J. Med. Virol. 85:2151–2159, 2013. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867 · cited 1×
“Models of transmission dynamics and the development of infection control guidelines and non-pharmaceutical interventions to prevent transmission, depend on data of the processes of virus shedding and distribution [Nicas et al., 2005; Kao and Yang, 2006; Nicas and Jones, 2009].”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Milton, D. K., Fabian, M. P., Cowling, B. J., Grantham, M. L., & McDevitt, J. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003205 · Cited by 669
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Self-citationInfluenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496 · cited 5×
“Studies by others have used optical particle counting to demonstrate that the majority of expelled particles are <0.5 mm in diameter; these studies however did not report virus carriage within the collected particles [Fabian et al., 2008, 2011a,b].”
BackgroundResultInfluentialThe Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473
Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423 · cited 8×
“Recent studies, concurrently measuring particle size and virus presence by PCR or cell culture, have reported the production of small ( 5 mm) particles carrying viruses, but have not examined the range of particle sizes produced [Fabian et al., 2008, 2011a,b; Lindsley et al., 2010].”
BackgroundResultInfluentialInhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362 · cited 2×
“Many earlier studies of particles generated by respiratory events have been conducted on healthy people [Papineni and Rosenthal, 1997; Edwards et al., 2004; Yang et al., 2007; Fang et al., 2008; Hersen et al., 2008; Morawska et al., 2008, 2009; Chao et al., 2009; Almstrand et al., 2010; Haslbeck et…”
BackgroundMethodLindsley, W. G., Pearce, T. A., Hudnall, J. B., Davis, K. A., Davis, S. M., Fisher, M. A., Khakoo, R., Palmer, J. E., Clark, K. E., Celik, I., et al. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.684582 · Cited by 300 · cited 4×
“Overall findings in this study complements the work of others, where particles sized <5 and 5 mm were produced by infected individuals on coughing and breathing [Fabian et al., 2008, 2011a,b; Lindsley et al., 2010; Lindsley et al., 2012; Milton et al., 2013], and previous work in which viral RNA and replication compet…”
BackgroundResultInfluential
Cited by
Airborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Transmissibility and transmission of respiratory viruses
Leung, N. H. L. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-021-00535-6 · Cited by 890
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
Eggers, M., Koburger-Janssen, T., Eickmann, M., & Zorn, J. (2018) · Infectious Diseases and Therapy · doi:10.1007/s40121-018-0200-7 · Cited by 386
Nazaroff, W. W. (2016) · Indoor Air · doi:10.1111/ina.12174 · Cited by 304
Eggers, M., Eickmann, M., & Zorn, J. (2015) · Infectious Diseases and Therapy · doi:10.1007/s40121-015-0091-9 · Cited by 229
“However, respiratory viruses are also subject to airborne (particles B5 lm in size) or droplet ([5 lm) transmission, in which infected material is released by the infected individual breathing, coughing or sneezing [21].”
Viable influenza A virus in airborne particles expelled during coughs versus exhalations
Lindsley, W. G., Blachere, F. M., Beezhold, D. H., Thewlis, R. E., Noorbakhsh, B., Othumpangat, S., Goldsmith, W. T., McMillen, C. M., Andrew, M. E., Burrell, C. N., et al. (2016) · Influenza and Other Respiratory Viruses · doi:10.1111/irv.12390 · Cited by 147
Metadata
- Authors
- Gralton, J., Tovey, E. R., McLaws, M., & Rawlinson, W. D.
- Venue
- Journal of Medical Virology
- Publisher
- Wiley
- Published
- 2013-08-19
- Volume
- 85
- Issue
- 12
- Pages
- 2151-2159
- ISSN
- 0146-6615 (ISSN-L)
- 1096-9071
- OpenAlex
- W1893470333
- Cited by
- 129
- References
- 15
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.