Comparison of the trabecular and cortical tissue moduli from human iliac crests
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to design a method to produce and test mechanically microspecimens of trabecular and cortical tissue from human iliac crests, and compare their measured moduli. Rectangular beam specimens were prepared on a low‐speed diamond blade saw and a miniature milling machine. The final specimen dimensions ranged from ∼50–200 μm for base and height. The modulus of each specimen was measured using three‐point bending tests across a span length of 1.04 mm and performed at a constant rate of displacement. A subset of specimens was recovered for a radiographic estimation of degree of mineralization. The results showed the mean trabecular tissue modulus of all iliac crest specimens to be 3.81 GPa, whereas cortical tissue specimens averaged 4.89 GPa. This was a significant difference according to a two‐way analysis of variance that controlled for differences between donors. No strong correlations were found between modulus and mineral density. Future investigations that consider other microstructural characteristics and their contributions to modulus, and specimen size effects, are indicated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Cited by
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
Basic biomechanical measurements of bone: A tutorial
Turner, C. H., & Burr, D. B. (1993) · Bone · doi:10.1016/8756-3282(93)90081-k · Cited by 1,666
“Testing of microspecimens has been done using three-point bending (Kuhn et al. 1989), fourpoint bending (Choi & Goldstein 19921, and tensile testing (Rho et al.”
MethodYoung's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
Biomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Self-citationElastic properties of microstructural components of human bone tissue as measured by nanoindentation
Rho, J.-Y., Roy, M. E., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199904)45:1<48::aid-jbm7>3.0.co;2-5 · Cited by 348
A 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Keaveny, T. M., & Hayes, W. C. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895536 · Cited by 318
Goldstein, S. A., Goulet, R., & McCubbrey, D. (1993) · Calcified Tissue International · doi:10.1007/bf01673421 · Cited by 310
Self-citationMethods for Assessing Bone Quality: A Review
Donnelly, E. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1702-0 · Cited by 300
Broadband ultrasound attenuation signals depend on trabecular orientation: An in vitro study
Glüer, C. C., Wu, C. Y., & Genant, H. K. (1993) · Osteoporosis International · doi:10.1007/bf01623674 · Cited by 272
Young’s modulus of trabecular bone at the tissue level: A review
Wu, D., Isaksson, P., Ferguson, S. J., & Persson, C. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.001 · Cited by 263
Heterogeneity of bone lamellar-level elastic moduli
Hoffler, C. E., Moore, K. E., Kozloff, K., Zysset, P. K., Brown, M. B., & Goldstein, S. A. (2000) · Bone · doi:10.1016/s8756-3282(00)00268-4 · Cited by 259
Self-citationBone tissue compositional differences in women with and without osteoporotic fracture
McCreadie, B. R., Morris, M. D., Chen, T.-C., Sudhaker Rao, D., Finney, W. F., Widjaja, E., & Goldstein, S. A. (2006) · Bone · doi:10.1016/j.bone.2006.06.008 · Cited by 253
Self-citationA comparison of the fatigue behavior of human trabecular and cortical bone tissue
Choi, K., & Goldstein, S. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90051-2 · Cited by 247
Self-citationMeganck, J. A., Kozloff, K. M., Thornton, M. M., Broski, S. M., & Goldstein, S. A. (2009) · Bone · doi:10.1016/j.bone.2009.07.078 · Cited by 185
“nearly two decades ago [8].”
Self-citationVan Rietbergen, B., Müller, R., Ulrich, D., Rüegsegger, P., & Huiskes, R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00150-x · Cited by 170
“Second, a unique Young’s modulus for all tissues was used in the model, whereas several investigators have found that the trabecular tissue properties are less than those of cortical bone (Rho et al., 1993; Choi et al., 1990; Kuhn et al., 1989).”
MethodLocal strain and damage mapping in single trabeculae during three-point bending tests
Jungmann, R., Szabo, M. E., Schitter, G., Yue-Sing Tang, R., Vashishth, D., Hansma, P. K., & Thurner, P. J. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.12.009 · Cited by 57
Novel method to analyze post-yield mechanical properties at trabecular bone tissue level
Carretta, R., Luisier, B., Bernoulli, D., Stüssi, E., Müller, R., & Lorenzetti, S. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.12.003 · Cited by 43
Metadata
- Authors
- Kuhn, J. L., Goldstein, S. A., Choi, R., London, M., Feldkamp, L. A., & Matthews, L. S.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1989-11
- Volume
- 7
- Issue
- 6
- Pages
- 876-884
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2059311075
- Cited by
- 164
- References
- 1
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.