Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
We evaluated the orthogonal mechanical properties of human trabecular bone from the major metaphyseal regions with materials testing and quantitative computed tomography (CT). The proximal tibia, distal femur, proximal femur, distal radius, and proximal humerus from fresh cadaver specimens between the ages of 55 and 70 years were excised and prepared for experimentation. The bones were embedded and scanned at 1 or 1.5 mm intervals on a Technicare HPS 1440 and GE 9800 CT scanner. After scanning, the bones were sectioned, producing 8‐mm cubes of trabecular bone which were mechanically tested in uniaxial compression at a strain rate of 1%/s. The testing sequence consisted of preyield tests in two of the three orthogonal directions and failure in the third. After testing, the cubes were evaluated for apparent density and ash weight. The results of the study show that the strength and stiffness of trabecular bone varies significantly within metaphyseal regions and from metaphysis to metaphysis. The power and significance of relationships between density and modulus varied as a function of metaphyseal location. Both linear and nonlinear models were significant, suggesting that trabecular deformation occurs in response to both axial and bending loads. Finally, the need for architectural measures of trabecular bone to predict mechanical properties is emphasized.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“The anisotropy that trabecular bone exhibits in microstructure is also present in elastic modulus (89) and strength (92).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Self-citationPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Self-citationMechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199001000-00020 · Cited by 284
Research works printed but not linked: 4
- Evans FG, 1961, Biomechanical Studies of the Musculoskeletal System, 49
- Wolff J, 1892, Das Gestez der Transformation der Knochen
- Yokoo S, 1952, Compression test of the cancellous bone, J Kyoto Pref Med Univ, 51, 273
- Arnold JS, 1960, Quantitation of mineralization of bone as an orgen and tissue in osteoporosis, Clin Orthop, 17, 167
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
“However, as has been reported previously (Ciarelli et al., 1991; Hvid et al., 1985; Keaveny, 1997), the limited density range exhibited by each site alone renders differences between predicted values from linear and power law models negligible.”
BackgroundResultQuantification of Bone Microarchitecture with the Structure Model Index
HILDEBRAND, T., & RÜEGSEGGER, P. (1997) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/01495739708936692 · Cited by 1,051
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.”
Fantner, G. E., Hassenkam, T., Kindt, J. H., Weaver, J. C., Birkedal, H., Pechenik, L., Cutroni, J. A., Cidade, G. A. G., Stucky, G. D., Morse, D. E., et al. (2005) · Nature Materials · doi:10.1038/nmat1428 · Cited by 933
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
“Although Ciarelli et al (26) reported a dependence of the regression coefficients in the power law relation on anatomic site, no specific statistical comparisons were given, and no other studies have compared strength across anatomic sites using the same test protocols and controlling for anisotropy for human bone.”
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
“A priori estimates for the ultimate strengths were based on previous experiments (Ciarelli et al., 1991).”
Self-citationDependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
“(1988) reported single ultimate stress–density regressions for data pooled from multiple sites, while subsequent studies reported that the regression coefficients did depend on site (Ciarelli et al., 1991) and on the density range of the data (Keller, 1994).”
BackgroundResultPrediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 682
Mathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
“That study shows that the density–modulus curves vary significantly with anatomical site, as previously noted by Ciarelli et al. (1991) and Goulet et al.”
BackgroundResultBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Three quantitative ultrasound parameters reflect bone structure
Gluer, C. C., Wu, C. Y., Jergas, M., Goldstein, S. A., & Genant, H. K. (1994) · Calcified Tissue International · doi:10.1007/bf00310168 · Cited by 424
Self-citationKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Majumdar, S., Kothari, M., Augat, P., Newitt, D. C., Link, T. M., Lin, J. C., Lang, T., Lu, Y., & Genant, H. K. (1998) · Bone · doi:10.1016/s8756-3282(98)00030-1 · Cited by 331
Biomechanical considerations of animal models used in tissue engineering of bone
Liebschner, M. A. K. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00515-5 · Cited by 329
“[21] and Kuhn et al.”
BackgroundHollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322
“…that the comparisons between predicted and experimental measures of stiffness were consistent, an 8 mm block with the anisotropit stiffness matrix calculated from the sampling procedure was analyzed under displacement conditions similar to those applied experimentally by Ciarelli et al. (1991).”
MethodInfluentialA 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Keaveny, T. M., & Hayes, W. C. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895536 · Cited by 318
Improved prediction of proximal femoral fracture load using nonlinear finite element models
Keyak, J. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00045-5 · Cited by 314
“These limitations are due to the large number of assumptions and approximations required, such as treating bone as an isotropic material even though it is highly anisotropic [22,33].”
BackgroundGoldstein, S. A., Goulet, R., & McCubbrey, D. (1993) · Calcified Tissue International · doi:10.1007/bf01673421 · Cited by 310
Self-citationKeyak, J. H., Lee, I. Y., & Skinner, H. B. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281111 · Cited by 287
Predicting Proximal Femoral Strength Using Structural Engineering Models
Keyak, J. H., Kaneko, T. S., Tehranzadeh, J., & Skinner, H. B. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000164400.37905.22 · Cited by 278
Taddei, F., Pancanti, A., & Viceconti, M. (2004) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00138-3 · Cited by 274
“logical tissues [6–8] over a wide range of density values.”
BackgroundHeterogeneity of bone lamellar-level elastic moduli
Hoffler, C. E., Moore, K. E., Kozloff, K., Zysset, P. K., Brown, M. B., & Goldstein, S. A. (2000) · Bone · doi:10.1016/s8756-3282(00)00268-4 · Cited by 259
Self-citationNuzzo, S., Peyrin, F., Cloetens, P., Baruchel, J., & Boivin, G. (2002) · Medical Physics · doi:10.1118/1.1513161 · Cited by 233
Scaffold Translation: Barriers Between Concept and Clinic
Hollister, S. J., & Murphy, W. L. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0251 · Cited by 224
Material properties assignment to finite element models of bone structures: a new method
Zannoni, C., Mantovani, R., & Viceconti, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00081-2 · Cited by 210
“In the particular case of living tissues, however, the relationship between CT numbers, Hounsfield Units (HU), and tissue density is monotonic and, as a first approximation, linear [3–5].”
BackgroundPrediction of fracture location in the proximal femur using finite element models
Keyak, J. H., Rossi, S. A., Jones, K. A., Les, C. M., & Skinner, H. B. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00094-7 · Cited by 199
“In particular, bone is anisotropic [15,17,23,24] and weaker in tension than in compression [23,25–27], but isotropic properties with equal tensile and compressive strengths were employed.”
BackgroundRole of Magnetic Resonance for Assessing Structure and Function of Trabecular Bone
Wehrli, F. W., Saha, P. K., Gomberg, B. R., Song, H. K., Snyder, P. J., Benito, M., Wright, A., & Weening, R. (2002) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200210000-00005 · Cited by 200
“0001) was found, which is in the range typically observed (71), leaving approximately 40% of the variance unexplained.”
BackgroundBouxsein, M. L., & Radloff, S. E. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.5.839 · Cited by 200
Ultrasound Velocity of Trabecular Cubes Reflects Mainly Bone Density and Elasticity
Hans, D., Wu, C., Njeh, C. F., Zhao, S., Augat, P., Newitt, D., Link, T., Lu, Y., Majumdar, S., & Genant, H. K. (1999) · Calcified Tissue International · doi:10.1007/s002239900572 · Cited by 196
“[42] who showed that strength and elasticity of cancellous bone vary significantly within metaphyseal regions.”
The role of an effective isotropic tissue modulus in the elastic properties of cancellous bone
Kabel, J., van Rietbergen, B., Dalstra, M., Odgaard, A., & Huiskes, R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00045-7 · Cited by 191
“However, the predictive value of bone volume fraction for bone strength is not very high, usually only 40}80% of the variation in strength can be explained by the volume fraction alone (Carter and Hayes, 1977; Ciarelli et al., 1991; Rice et al., 1988).”
BackgroundTHOMSEN, J. S., LAIB, A., KOLLER, B., PROHASKA, S., MOSEKILDE, L., & GOWIN, W. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01469.x · Cited by 188
“…the loss of trabecular bone density, but also on the loss of structural elements as well as a loss of connectivity (Kleerekoper et al ., 1985; Goldstein, 1987; Parfitt, 1987; Mosekilde, 1988, 1989, 1993; Ciarelli et al ., 1991; Delling & Amling, 1995; Majumdar et al ., 1998; Gomberg et al ., 2000).”
Schneider, P., Stauber, M., Voide, R., Stampanoni, M., Donahue, L. R., & Müller, R. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070703 · Cited by 187
“of the variation in strength of trabecular bone.((5)) This also means that 90–10% of the variation in strength cannot be explained by BMD.”
BackgroundMethodAge‐related variations in the microstructure of human tibial cancellous bone
Ding, M., Odgaard, A., Linde, F., & Hvid, I. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00132-2 · Cited by 186
Jaecques, S. V. N., Van Oosterwyck, H., Muraru, L., Van Cleynenbreugel, T., De Smet, E., Wevers, M., Naert, I., & Vander Sloten, J. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00516-7 · Cited by 186
“As to the latter, it has been shown experimentally that the Hounsfield values (grey values), which are a measure for the attenuation coefficient of the material (relative to the attenuation coefficient of water), can be used to predict the Young’s modulus of trabecular bone [17,18].”
MethodDing, M., Odgaard, A., Hvid, I., & Hvid, I. (2003) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.85b6.12595 · Cited by 177
Experimental and finite element study of a human mandible
Vollmer, D., Meyer, U., Joos, U., Vègh, A., & Piffkò, J. (2000) · Journal of Cranio-Maxillofacial Surgery · doi:10.1054/jcms.2000.0125 · Cited by 174
Hierarchical microimaging of bone structure and function
Müller, R. (2009) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2009.107 · Cited by 168
Kaneko, T. S., Bell, J. S., Pejcic, M. R., Tehranzadeh, J., & Keyak, J. H. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.08.010 · Cited by 169
“In addition, the similar correlation coefficients found in the present and previous studies (Ciarelli et al., 1991; Keyak et al., 1994) suggest that including different types of cancer did not introduce significant confounding factors.”
BackgroundResultInfluentialConnectivity and the elastic properties of cancellous bone
Kabel, J., Odgaard, A., van Rietbergen, B., & Huiskes, R. (1999) · Bone · doi:10.1016/s8756-3282(98)00164-1 · Cited by 168
Effect of freeze‐drying and gamma irradiation on the mechanical properties of human cancellous bone
Cornu, O., Banse, X., Docquier, P. L., Luyckx, S., & Delloye, C. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180314 · Cited by 169
Fazzalari, N. L., Forwood, M. R., Smith, K., Manthey, B. A., & Herreen, P. (1998) · Bone · doi:10.1016/s8756-3282(97)00298-6 · Cited by 168
Seebeck, J., Goldhahn, J., Städele, H., Messmer, P., Morlock, M. M., & Schneider, E. (2004) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2004.04.001 · Cited by 166
Time-lapsed microstructural imaging of bone failure behavior
Nazarian, A., & Müller, R. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00254-9 · Cited by 165
“On an individual basis, density alone accounts for 10–90% of the variation in strength of trabecular bone (Ciarelli et al., 1991).”
BackgroundThe effect of impact direction on the structural capacity of the proximal femur during falls
Ford, C. M., Keaveny, T. M., & Hayes, W. C. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110311 · Cited by 157
Cortical and trabecular bone contribute strength to the osteopenic distal radius
Spadaro, J. A., Werner, F. W., Brenner, R. A., Fortino, M. D., Fay, L. A., & Edwards, W. T. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120210 · Cited by 173
A modified method for assigning material properties to FE models of bones
Helgason, B., Taddei, F., Pálsson, H., Schileo, E., Cristofolini, L., Viceconti, M., & Brynjólfsson, S. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.006 · Cited by 155
Yosibash, Z., Padan, R., Joskowicz, L., & Milgrom, C. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2720906 · Cited by 144
“Density evaluation based on the K2HPO4 phantom present in the CT scan [35] resulted in very similar results.”
BackgroundResultImpact of Spatial Resolution on the Prediction of Trabecular Architecture Parameters
Kothari, M., Keaveny, T. M., Lin, J. C., Newitt, D. C., Genant, H. K., & Majumdar, S. (1998) · Bone · doi:10.1016/s8756-3282(98)00031-3 · Cited by 181
Topological analysis of trabecular bone MR images
Gomberg, B. R., Saha, P. K., Song, H. K., Hwang, S. N., & Wehrli, F. W. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845175 · Cited by 141
Perilli, E., Baleani, M., Öhman‐Mägi, C., Fognani, R., Baruffaldi, F., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.08.003 · Cited by 158
“The ash density was obtained by dividing the ash weight by the volume of the bone specimens determined from the diameter and height measured before compressive testing (Ciarelli et al., 1991).”
BackgroundMethodResultDong, P., Haupert, S., Hesse, B., Langer, M., Gouttenoire, P.-J., Bousson, V., & Peyrin, F. (2013) · Bone · doi:10.1016/j.bone.2013.12.008 · Cited by 168
“However, bone mass could explain only a fraction of change in bone strength among individuals [1].”
Hellmich, C., Kober, C., & Erdmann, B. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9393-8 · Cited by 142
Age, gender, and bone lamellae elastic moduli
Hoffler, C. E., Moore, K. E., Kozloff, K., Zysset, P. K., & Goldstein, S. A. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180315 · Cited by 129
Self-citationSeedhom, B. B., Berry, E., Ostell, A., & Cuppone, M. (2004) · Calcified Tissue International · doi:10.1007/s00223-002-2123-1 · Cited by 165
Prediction of mechanical properties of cortical bone by quantitative computed tomography
Duchemin, L., Bousson, V., Raossanaly, C., Bergot, C., Laredo, J. D., Skalli, W., & Mitton, D. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.04.008 · Cited by 149
Thurner, P. J., Wyss, P., Voide, R., Stauber, M., Stampanoni, M., Sennhauser, U. J., & Müller, R. (2006) · Bone · doi:10.1016/j.bone.2006.01.147 · Cited by 144
“In fact bone density alone accounts for 10 to 90% of the variation in trabecular bone strength on an individual basis [9] leaving 90 to 10% of the variation unexplained.”
BackgroundTrabecular bone morphology from micro-magnetic resonance imaging
Hipp, J. A., Jansujwicz, A., Simmons, C. A., & Snyder, B. D. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110218 · Cited by 138
Standardizing compression testing for measuring the stiffness of human bone
Zhao, S., Arnold, M. C. A., Ma, S., Abel, R. L., Cobb, J. P., Hansen, U. N., & Boughton, O. R. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.78.bjr-2018-0025.r1 · Cited by 151
Thurner, P. J., Erickson, B. W., Jungmann, R., Schriock, Z., Weaver, J. C., Fantner, G. E., Schitter, G., Morse, D. E., & Hansma, P. K. (2006) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2006.05.024 · Cited by 140
“In fact sometimes up to 90% of the variation in bone strength are left unexplained on an individual basis [4], indicating the severe limitations in assessing fracture risk in patients by measuring bone density.”
BackgroundAnisotropy of the elastic modulus of trabecular bone specimens from different anatomical locations
Augat, P., Link, T. M., Lang, T., Lin, J. C., Majumdar, S., & Genant, H. K. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00001-0 · Cited by 140
“[23], who found that the correlations of BMD and compressive stiffness were strongest in the AP direction and had the steepest slope in this direction.”
BackgroundResultInfluentialA 3D damage model for trabecular bone based on fabric tensors
Zysset, P. K., & Curnier, A. (1996) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)80006-6 · Cited by 117
Song, Y.-Y., Cha, J., & Hwang, C. (2007) · The Angle Orthodontist · doi:10.2319/090606-363.1 · Cited by 117
Prediction of Human Femoral Bone Strength Using Ultrasound Velocity and BMD: An In Vitro Study
Njeh, C. F., Kuo, C. W., Langton, C. M., Atrah, H. I., & Boivin, C. M. (1997) · Osteoporosis International · doi:10.1007/s001980050035 · Cited by 118
“[6] who showed that the strength and Young’s modulus of cancellous bone vary significantly within metaphyseal regions.”
Öhman‐Mägi, C., Baleani, M., Perilli, E., Dall’Ara, E., Tassani, S., Baruffaldi, F., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.11.020 · Cited by 136
“It has been demonstrated that orthotropic behaviour of cancellous bone is related to the specific anatomical region (Augat et al., 1998; Ciarelli et al., 1991; Majumdar et al., 1998).”
BackgroundKamibayashi, L., WYSS, U. P., Cooke, T. D. V., & Zee, B. C.-Y. (1995) · Bone · doi:10.1016/8756-3282(95)00137-3 · Cited by 113
Permeability studies of artificial and natural cancellous bone structures
Syahrom, A., Kadir, M. R. A., Abdullah, J., & Öchsner, A. Ö. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.08.011 · Cited by 115
Micro-compression: a novel technique for the nondestructive assessment of local bone failure
Müller, R., Gerber, S. C., & Hayes, W. C. (1998) · Technology and Health Care · doi:10.3233/thc-1998-65-616 · Cited by 112
“On an individual basis, density alone accounts for 10–90% of the variation in the strength of trabecular bone [6].”
Kazakia, G. J., Burghardt, A. J., Cheung, S., & Majumdar, S. (2008) · Medical Physics · doi:10.1118/1.2924210 · Cited by 114
Ding, M., Odgaard, A., Danielsen, C. C., & Hvid, I. (2002) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.84b6.0840900 · Cited by 110
“8.(28) Our result of the correlation between Young’s modulus and density was at the lower end but still within the normal expected range.”
BackgroundMiniscrew stability evaluated with computerized tomography scanning
Cha, J., Kil, J.-K., Yoon, T.-M., & Hwang, C. (2009) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2008.03.024 · Cited by 107
Nonlinear Behavior of Trabecular Bone at Small Strains
Morgan, E. F., Yeh, O. C., Chang, W. C., & Keaveny, T. M. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1338122 · Cited by 107
A Global Relationship Between Trabecular Bone Morphology and Homogenized Elastic Properties
Zysset, P. K., Goulet, R. W., & Hollister, S. J. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834756 · Cited by 105
Excised Bone Structures in Mice: Imaging at Three-dimensional Synchrotron Radiation Micro CT
Martín-Badosa, E., Amblard, D., Nuzzo, S., Elmoutaouakkil, A., Vico, L., & Peyrin, F. (2003) · Radiology · doi:10.1148/radiol.2293020558 · Cited by 106
New imaging technologies in the diagnosis of osteoporosis
Kazakia, G. J., & Majumdar, S. (2006) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-006-9004-2 · Cited by 129
Effects of High-Fat Diet on Mature Bone Mineral Content, Structure, and Mechanical Properties
Wohl, G. R., Loehrke, L., Watkins, B. A., & Zernicke, R. F. (1998) · Calcified Tissue International · doi:10.1007/s002239900492 · Cited by 102
Finite-Element Modeling of Bones From CT Data: Sensitivity to Geometry and Material Uncertainties
Taddei, F., Martelli, S., Reggiani, B., Cristofolini, L., & Viceconti, M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879473 · Cited by 104
Biomechanics of Age-Related Fractures
Bouxsein, M. (2001) · Elsevier eBooks · doi:10.1016/b978-012470862-4/50020-9 · Cited by 109
Atomic force microscopy and indentation force measurement of bone
Thurner, P. J. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.56 · Cited by 96
Dopico-González, C., New, A., & Browne, M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.039 · Cited by 96
“Journal of Bio anisotropic (Ciarelli et al., 1991; Keaveny et al., 2001).”
Bone microarchitecture assessment: current and future trends
M�ller, R. (2003) · Osteoporosis International · doi:10.1007/s00198-003-1479-z · Cited by 96
“On an individual basis, density alone accounts for 10 to 90% of the variation in the strength of trabecular bone [1].”
BackgroundMueller, T. L., Stauber, M., Kohler, T., Eckstein, F., Müller, R., & van Lenthe, H. (2008) · Bone · doi:10.1016/j.bone.2008.10.045 · Cited by 110
“For this reason, microstructural information is of great importance and must be included in the analysis to accurately predict individual mechanical bone properties [12–21].”
Barvencik, F., Gebauer, M., Beil, F. T., Vettorazzi, E., Mumme, M., Rupprecht, M., Pogoda, P., Wegscheider, K., Rueger, J. M., Pueschel, K., et al. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20957 · Cited by 91
Hwang, S. N., Wehrli, F. W., & Williams, J. L. (1997) · Medical Physics · doi:10.1118/1.598147 · Cited by 86
Colombet, P. D., Graveleau, N., & Jambou, S. (2016) · The American Journal of Sports Medicine · doi:10.1177/0363546516656181 · Cited by 93
“tunnel prepared to improve fixation strength, especially in women in whom the tibial cancellous bone is often relatively soft.(8,10) The second reason for enlargement may be the acidic degradation of the resorbable polymer, which caused the formation of cysts in 7 knees (14.”
BackgroundShear strength behavior of human trabecular bone
Sanyal, A., Gupta, A. K., Bayraktar, H. H., Kwon, R. Y., & Keaveny, T. M. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.07.023 · Cited by 107
“Since trabecular bone is thought to be primarily adapted to sustain compressive loads along its main trabecular orientation, most focus to date in biomechanical studies of human trabecular bone has been placed on understanding its compressive strength behavior (Carter and Hayes, 1976; Ciarelli et al., 1991; Goldstein,…”
BackgroundHuman Models for Crash and Impact Simulation
Haug, E., Choi, H.-Y., Robin, S., & Beaugonin, M. (2004) · Handbook of numerical analysis · doi:10.1016/s1570-8659(03)12004-2 · Cited by 109
Johnston, J. D., Masri, B. A., & Wilson, D. R. (2009) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2009.04.013 · Cited by 83
Guan, H., van Staden, R., Loo, Y., Johnson, N. W., Ivanovski, S., & Meredith, N. (2009) · PubMed · Cited by 83
Application of the Tsai–Wu Quadratic Multiaxial Failure Criterion to Bovine Trabecular Bone
Keaveny, T. M., Wachtel, E. F., Zadesky, S. P., & Arramon, Y. P. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798051 · Cited by 80
Judex, S., Boyd, S. K., Qin, Y., Miller, L. M., Müller, R., & Rubin, C. T. (2003) · Current Osteoporosis Reports · doi:10.1007/s11914-003-0003-x · Cited by 91
“However, there is a considerable overlap in bone densities among normal individuals and those that sustain fractures, indicating that low bone mass cannot solely explain the increased fracture rate in the postmenopausal and aging population [6].”
BackgroundMessent, E. A., Ward, R. J., Tonkin, C. J., & Buckland-Wright, C. (2005) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2005.01.007 · Cited by 79
Harrison, N. M., McDonnell, P., O’Mahoney, D., Kennedy, O. D., O’Brien, F. J., & McHugh, P. E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.014 · Cited by 100
Sverdlova, N. S., & Witzel, U. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.049 · Cited by 90
Anticipating bipedalism: trabecular organization in the newborn ilium
Cunningham, C. A., & Black, S. M. (2009) · Journal of Anatomy · doi:10.1111/j.1469-7580.2009.01073.x · Cited by 81
“The relationship between bone form and function is well understood and has been investigated extensively in early studies from the 19th century (Ward, 1838; Von Mayer, 1867; Wolff, 1892, 1986; Evans, 1957), through seminal work in the past decades (Evans, 1973; Lanyon, 1974; Carter & Hayes, 1977; Gibson, 1985; Goldste…”
BackgroundMcCubbrey, D. A., CODY, D. D., Peterson, E. L., Kuhn, J. L., Flynn, M. J., & Goldstein, S. A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00155-w · Cited by 73
“Because previous studies (Ciarelli et al., 1991; Cody et al., 1991) have established linear relationships between CT density and mechanical properties, we felt that linear models would allow us to focus on the comparison of simple versus multiple regression approaches. To address our second hypothesis (that regions wi…”
BackgroundMethodSelf-citationPerilli, E., Baleani, M., Öhman‐Mägi, C., Baruffaldi, F., & Viceconti, M. (2007) · Bone · doi:10.1016/j.bone.2007.07.014 · Cited by 79
“For these regressions, linear or power models are reported in the literature [3,17,27,41,43,50,52,75].”
BackgroundMethodCompressive properties of trabecular bone in the distal femur
Burgers, T., Mason, J., Niebur, G. L., & Ploeg, H. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.11.018 · Cited by 77
“The mechanical properties of the bone can be assigned from empirical relationships between properties and QCT density (McBroom et al., 1985; Esses et al., 1989; Hvid et al., 1989; Lotz et al., 1990; Ciarelli et al., 1991; Rho et al., 1995).”
BackgroundMansat, P., Briot, J., Mansat, M., & Swider, P. (2006) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2005.11.010 · Cited by 69
Gordon, C. L., Webber, C. E., Christoforou, N., & Nahmias, C. (1997) · Medical Physics · doi:10.1118/1.597987 · Cited by 69
Metadata
- Authors
- Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B.
- Affiliations
- University of Michigan (US)
- Henry Ford Health (US)
- Corresponding author
- Goldstein, S. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 9
- Issue
- 5
- Pages
- 674-682
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2048282929
- Cited by
- 401
- References
- 28
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 16 · 2023: 21 · 2022: 7 · 2021: 12 · 2020: 13 · 2019: 9 · 2018: 12 · 2017: 8 · 2016: 8 · 2015: 7 · 2014: 17 · 2013: 14 · 2012: 11
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ar034399-12)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR34399)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, bone mineral density, elastic modulus, uniaxial compression, flexural failure, trabecular bone microarchitecture, cadaveric bone, tibia, femur, radius, humerus, bone strength
- MeSH terms
- Aged, Biomechanical Phenomena, Bone and Bones, Humans, Male, Middle Aged, Tomography, X-Ray Computed, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.