The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Systematic and random errors in compression testing of trabecular bone
Abstract
We sought to quantify the systematic and random errors associated with‐artifacts in the platens compression test for trabecular bone. Our hypothesis was that while errors may depend on anatomic site, they do not depend on apparent density and therefore have substantial random components. Trabecular bone specimens were first tested nondestructively using newly developed accurate protocols and then were tested again using the platens compression test. Percentage differences in modulus between the techniques (bovine) proximal tibia [n = 18] and humerus [n = 17] and human lumbar spine, [n = 9] were in the range of 4‐86%. These differences did not depend on anatomic site (p = 0.21) and were only weakly dependent on apparent density and specimen aspect ratio (r 2 < 0.10). The mean percentage difference in modulus was 32.6% representing the systematic component of the end‐artifact error. Neglecting the minor variations explained by density and specimen size (approximately 10%), an upper bound on the random error from end‐artifacts in this experiment was taken as the SD of the modulus difference (±18.2%). Based on a synthesis of data taken from this study and from the literature, we concluded that the systematic underestimation error in the platens compression test can be only approximated and is in the range of 20‐40%; the substantial random error (±12.5%) confounds correction, particularly when the sample size is small. These errors should be considered when interpreting results from the platens test, and more accurate testing techniques should be used when such errors are not acceptable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationHollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90053-1 · Cited by 300
Self-citationThe effect of specimen geometry on the mechanical behaviour of trabecular bone specimens
Linde, F., Hvid, I., & Madsen, F. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90255-y · Cited by 233
Elastic properties of cancellous bone: Measurement by an ultrasonic technique
Ashman, R. B., Corin, J. D., & Turner, C. H. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90327-7 · Cited by 227
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225
Faulkner, K. G., Cann, C. E., & Hasegawa, B. H. (1991) · Radiology · doi:10.1148/radiology.179.3.2027972 · Cited by 215
Cheal, E. J., Spector, M., & Hayes, W. C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100314 · Cited by 213
The effect of constraint on the mechanical behaviour of trabecular bone specimens
Linde, F., & Hvid, I. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90209-1 · Cited by 181
Trabecular bone modulus and strength can depend on specimen geometry
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90059-n · Cited by 160
Self-citationTheoretical analysis of the experimental artifact in trabecular bone compressive modulus
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90021-6 · Cited by 136
Self-citationHodgskinson, R., & Currey, J. D. (1990) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1990_204_240_02 · Cited by 136
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895413 · Cited by 117
Compressive axial strain distributions in cancellous bone specimens
Odgaard, A., Hvid, I., & Linde, F. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90066-3 · Cited by 86
Zhu, M., Keller, T. S., & Spengler, D. M. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90032-9 · Cited by 46
Skinner, H. B., Kim, A. S., Keyak, J. H., & Mote, C. D. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120412 · Cited by 45
Cited by
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Self-citationComparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Self-citationBiomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationThe ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718
Metadata
- Authors
- Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 15
- Issue
- 1
- Pages
- 101-110
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1977514725
- Cited by
- 377
- References
- 19
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.