Systematic and random errors in compression testing of trabecular bone
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
We sought to quantify the systematic and random errors associated with‐artifacts in the platens compression test for trabecular bone. Our hypothesis was that while errors may depend on anatomic site, they do not depend on apparent density and therefore have substantial random components. Trabecular bone specimens were first tested nondestructively using newly developed accurate protocols and then were tested again using the platens compression test. Percentage differences in modulus between the techniques (bovine) proximal tibia [n = 18] and humerus [n = 17] and human lumbar spine, [n = 9] were in the range of 4‐86%. These differences did not depend on anatomic site (p = 0.21) and were only weakly dependent on apparent density and specimen aspect ratio (r 2 < 0.10). The mean percentage difference in modulus was 32.6% representing the systematic component of the end‐artifact error. Neglecting the minor variations explained by density and specimen size (approximately 10%), an upper bound on the random error from end‐artifacts in this experiment was taken as the SD of the modulus difference (±18.2%). Based on a synthesis of data taken from this study and from the literature, we concluded that the systematic underestimation error in the platens compression test can be only approximated and is in the range of 20‐40%; the substantial random error (±12.5%) confounds correction, particularly when the sample size is small. These errors should be considered when interpreting results from the platens test, and more accurate testing techniques should be used when such errors are not acceptable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationHollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90053-1 · Cited by 300
Self-citationThe effect of specimen geometry on the mechanical behaviour of trabecular bone specimens
Linde, F., Hvid, I., & Madsen, F. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90255-y · Cited by 233
Elastic properties of cancellous bone: Measurement by an ultrasonic technique
Ashman, R. B., Corin, J. D., & Turner, C. H. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90327-7 · Cited by 227
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225
Faulkner, K. G., Cann, C. E., & Hasegawa, B. H. (1991) · Radiology · doi:10.1148/radiology.179.3.2027972 · Cited by 215
Cited by
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Self-citationComparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Self-citationBiomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationThe ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
“However, strain measurements obtained in this manner can result in a loss of precision due to the effect of sampling at one location on the irregular specimen surface rather than across the entire crosssection and gage length (Keaveny et al., 1997).”
BackgroundMethodSelf-citationYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653
Self-citationMathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
Biomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431
Self-citationSubject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 330
Biomechanical considerations of animal models used in tissue engineering of bone
Liebschner, M. A. K. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00515-5 · Cited by 329
The influence of bone volume fraction and ash fraction on bone strength and modulus
Hernandez, C. J., Beaupré, G. S., Keller, T. S., & Carter, D. R. (2001) · Bone · doi:10.1016/s8756-3282(01)00467-7 · Cited by 309
The use of digital image correlation in the biomechanical area: a review
Palanca, M., Tozzi, G., & Cristofolini, L. (2016) · International Biomechanics · doi:10.1080/23335432.2015.1117395 · Cited by 304
Fundamentals of Biomechanics in Tissue Engineering of Bone
Athanasiou, K. A., Zhu, C.-F., Lanctot, D. R., Agrawal, C. M., & Wang, X. (2000) · Tissue Engineering · doi:10.1089/107632700418083 · Cited by 301
Kopperdahl, D. L., Morgan, E. F., & Keaveny, T. M. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00185-1 · Cited by 267
Self-citationBanse, X., Sims, T. J., & Bailey, A. J. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.9.1621 · Cited by 267
Nazarian, A., von Stechow, D., Zurakowski, D., Müller, R., & Snyder, B. D. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9174-x · Cited by 244
“This reduced end artifact [31] by providing support to the free ends of trabeculae at either end of the specimen.”
BackgroundMa, S., Tang, Q., Han, X., Feng, Q., Song, J., Setchi, R., Liu, Y., Liu, Y., Goulas, A., Engstrøm, D. S., et al. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.109034 · Cited by 237
A review of morphology–elasticity relationships in human trabecular bone: theories and experiments
Zysset, P. K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00128-3 · Cited by 223
Kabel, J., van Rietbergen, B., Odgaard, A., & Huiskes, R. (1999) · Bone · doi:10.1016/s8756-3282(99)00190-8 · Cited by 206
Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic
Giesen, E. B. W., Ding, M., Dalstra, M., & van Eijden, T. M. G. J. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00030-6 · Cited by 201
“Further, the compression tests between parallel plates generate systematical and random errors (Keaveny et al., 1997).”
BackgroundPatel, P. S., Shepherd, D. E., & Hukins, D. W. (2008) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-9-137 · Cited by 197
Compressive behaviour of child and adult cortical bone
Öhman, C., Baleani, M., Pani, C., Taddei, F., Alberghini, M., Viceconti, M., & Manfrini, M. (2011) · Bone · doi:10.1016/j.bone.2011.06.035 · Cited by 181
Whole Bone Mechanics and Bone Quality
Cole, J. H., & van der Meulen, M. C. H. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1784-3 · Cited by 169
“BV/TV and apparent density can explain 60% to 85% of the experimentally measured variability in compressive apparent stiffness and strength of human cancellous bone [66, 73, 79, 80, 88].”
Mechanical behavior of human trabecular bone after overloading
Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170308 · Cited by 155
“method has been validated Tor monotonic loading (21,23).”
BackgroundMethodSelf-citationThe Anisotropic Hooke's Law for Cancellous Bone and Wood
Yang, G., Kabel, J., Van Rietbergen, B., Odgaard, A., Huiskes, R., & Cown, S. C. (1998) · Journal of Elasticity · doi:10.1023/a:1007575322693 · Cited by 140
Matsuura, M., Eckstein, F., Lochmüller, E.-M., & Zysset, P. K. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0073-7 · Cited by 117
Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170418 · Cited by 77
Self-citationAnisotropy of the fatigue behaviour of cancellous bone
Dendorfer, S., Maier, H. J., Taylor, D., & Hammer, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.037 · Cited by 76
Yamamoto, E., Paul Crawford, R., Chan, D. D., & Keaveny, T. M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.017 · Cited by 72
Self-citationDamage in trabecular bone at small strains
Morgan, E., Yeh, O., & Keaveny, T. (2005) · European Journal of Morphology · doi:10.1080/09243860500095273 · Cited by 59
Self-citationHeterogeneity of yield strain in low-density versus high-density human trabecular bone
Bevill, G., Farhamand, F., & Keaveny, T. M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.023 · Cited by 57
“To minimize the endartifacts, the vertebral cores were affixed in brass endcaps (Keaveny et al., 1997) and strain was measured using a 25 mm gage length extensometer (632.11F-20, MTS, Eden Prairie, MN) attached to the endcaps.”
MethodSelf-citationPost-yield relaxation behavior of bovine cancellous bone
Burgers, T. A., Lakes, R. S., García-Rodríguez, S., Piller, G. R., & Ploeg, H.-L. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.005 · Cited by 10
“10 g/cm, was typical for cancellous bone as reported in previous studies (Carter and Hayes, 1977; Keaveny et al., 1997).”
BackgroundMethodResultInfluential
Metadata
- Authors
- Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 15
- Issue
- 1
- Pages
- 101-110
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1977514725
- Cited by
- 377
- References
- 19
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.