The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Selective laser melting‐produced porous titanium scaffolds regenerate bone in critical size cortical bone defects
Open accessAbstract
Porous titanium scaffolds have good mechanical properties that make them an interesting bone substitute material for large bone defects. These scaffolds can be produced with selective laser melting, which has the advantage of tailoring the structure's architecture. Reducing the strut size reduces the stiffness of the structure and may have a positive effect on bone formation. Two scaffolds with struts of 120‐µm (titanium‐120) or 230‐µm (titanium‐230) were studied in a load‐bearing critical femoral bone defect in rats. The defect was stabilized with an internal plate and treated with titanium‐120, titanium‐230, or left empty. In vivo micro‐CT scans at 4, 8, and 12 weeks showed more bone in the defects treated with scaffolds. Finally, 18.4 ± 7.1 mm 3 (titanium‐120, p = 0.015) and 18.7 ± 8.0 mm 3 (titanium‐230, p = 0.012) of bone was formed in those defects, significantly more than in the empty defects (5.8 ± 5.1 mm 3). Bending tests on the excised femurs after 12 weeks showed that the fusion strength reached 62% (titanium‐120) and 45% (titanium‐230) of the intact contralateral femurs, but there was no significant difference between the two scaffolds. This study showed that in addition to adequate mechanical support, porous titanium scaffolds facilitate bone formation, which results in high mechanical integrity of the treated large bone defects. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31: 792–799, 2013
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morbidity at Bone Graft Donor Sites
Younger, E. M., & Chapman, M. W. (1989) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-198909000-00002 · Cited by 2,012
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Fracture healing: The diamond concept
Giannoudis, P. V., Einhorn, T. A., & Marsh, D. (2007) · Injury · doi:10.1016/s0020-1383(08)70003-2 · Cited by 1,092
Bone graft and bone graft substitutes: A review of current technology and applications
Damien, C. J., & Parsons, J. R. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020307 · Cited by 1,058
Heinl, P., Müller, L., Körner, C., Singer, R. F., & Müller, F. A. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.03.013 · Cited by 815
Antibacterial nano-structured titania coating incorporated with silver nanoparticles
Zhao, L., Wang, H., Huo, K., Cui, L., Zhang, W., Ni, H., Zhang, Y., Wu, Z., & Chu, P. K. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.040 · Cited by 772
Murr, L. E., Gaytan, S. M., Medina, F., Lopez, H., Martinez, E., Machado, B. I., Hernandez, D. H., Martinez, L., Lopez, M. I., Wicker, R. B., et al. (2010) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2010.0010 · Cited by 636
Osteoinduction of porous bioactive titanium metal
Fujibayashi, S., Neo, M., Kim, H.-M., Kokubo, T., & Nakamura, T. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00551-9 · Cited by 492
Hollander, D. A., von Walter, M., Wirtz, T., Sellei, R., Schmidt-Rohlfing, B., Paar, O., & Erli, H.-J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.041 · Cited by 482
Processing and biocompatibility evaluation of laser processed porous titanium
Xue, W., Krishna, B. V., Bandyopadhyay, A., & Bose, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.05.009 · Cited by 471
Cited by
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Sing, S. L., An, J., Yeong, W. Y., & Wiria, F. E. (2016) · Journal of Orthopaedic Research · doi:10.1002/jor.23075 · Cited by 942
Roland, L., Grau, M., Matena, J., Teske, M., Gieseke, M., Kampmann, A., Beyerbach, M., Murua Escobar, H., Haferkamp, H., Gellrich, N.-C., et al. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms17010001 · Cited by 862
X-ray computed tomography for additive manufacturing: a review
Thompson, A., Maskery, I., & Leach, R. K. (2016) · Measurement Science and Technology · doi:10.1088/0957-0233/27/7/072001 · Cited by 521
Bone tissue regeneration: the role of scaffold geometry
Zadpoor, A. A. (2015) · Biomaterials Science · doi:10.1039/c4bm00291a · Cited by 518
Self-citationWauthle, R., Vrancken, B., Beynaerts, B., Jorissen, K., Schrooten, J., Kruth, J.-P., & Van Humbeeck, J. (2015) · Additive Manufacturing · doi:10.1016/j.addma.2014.12.008 · Cited by 463
Improving biocompatibility for next generation of metallic implants
Bandyopadhyay, A., Mitra, I., Goodman, S. B., Kumar, M., & Bose, S. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101053 · Cited by 463
Mechanical behavior of regular open-cell porous biomaterials made of diamond lattice unit cells
Ahmadi, S. M., Campoli, G., Amin Yavari, S., Sajadi, B., Wauthle, R., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2014) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.02.003 · Cited by 442
Self-citationAmin Yavari, S., Ahmadi, S. M., Wauthle, R., Pouran, B., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.12.015 · Cited by 431
Self-citationAdditively manufactured porous tantalum implants
Wauthle, R., van der Stok, J., Amin Yavari, S., Van Humbeeck, J., Kruth, J.-P., Zadpoor, A. A., Weinans, H., Mulier, M., & Schrooten, J. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.12.003 · Cited by 417
Self-citationMechanical properties of open-cell metallic biomaterials manufactured using additive manufacturing
Campoli, G., Borleffs, M. S., Amin Yavari, S., Wauthle, R., Weinans, H., & Zadpoor, A. A. (2013) · Materials & Design · doi:10.1016/j.matdes.2013.01.071 · Cited by 404
Self-citationAhmadi, S., Yavari, S., Wauthle, R., Pouran, B., Schrooten, J., Weinans, H., & Zadpoor, A. (2015) · Materials · doi:10.3390/ma8041871 · Cited by 399
Self-citationAdditively manufactured biodegradable porous magnesium
Li, Y., Zhou, J., Pavanram, P., Leeflang, M. A., Fockaert, L. I., Pouran, B., Tümer, N., Schröder, K.-U., Mol, J. M. C., Weinans, H., et al. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.12.008 · Cited by 396
Self-citationLiu, F., Mao, Z., Zhang, P., Zhang, D. Z., Jiang, J., & Ma, Z. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.09.053 · Cited by 395
3D Printing of Calcium Phosphate Ceramics for Bone Tissue Engineering and Drug Delivery
Trombetta, R., Inzana, J. A., Schwarz, E. M., Kates, S. L., & Awad, H. A. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1678-3 · Cited by 377
Fatigue behavior of porous biomaterials manufactured using selective laser melting
Amin Yavari, S., Wauthle, R., van der Stok, J., Riemslag, A. C., Janssen, M., Mulier, M., Kruth, J. P., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.08.006 · Cited by 357
Self-citationMahmoud, D., & Elbestawi, M. (2017) · Journal of Manufacturing and Materials Processing · doi:10.3390/jmmp1020013 · Cited by 338
Bone regeneration performance of surface-treated porous titanium
Amin Yavari, S., van der Stok, J., Chai, Y. C., Wauthle, R., Tahmasebi Birgani, Z., Habibovic, P., Mulier, M., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.054 · Cited by 297
Self-citationBobbert, F. S. L., & Zadpoor, A. A. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb00741h · Cited by 296
Self-citationZhang, X. Z., Leary, M., Tang, H. P., Song, T., & Qian, M. (2018) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2018.05.002 · Cited by 285
Zhang, X.-Y., Fang, G., Leeflang, S., Böttger, A. J., A. Zadpoor, A., & Zhou, J. (2018) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.11.263 · Cited by 274
Baino, F., & Yamaguchi, S. (2020) · Biomimetics · doi:10.3390/biomimetics5040057 · Cited by 264
Zhao, S., Li, S. J., Hou, W. T., Hao, Y. L., Yang, R., & Misra, R. D. K. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.01.034 · Cited by 262
Department of Orthopaedics, U. U., Koolen, M., Longoni, A., van der Stok, J., Van der Jagt, O., Gawlitta, D., & Weinans, H. (2019) · European Cells and Materials · doi:10.22203/ecm.v038a08 · Cited by 24
Self-citation
Metadata
- Authors
- Van der Stok, J., Van der Jagt, O. P., Amin Yavari, S., De Haas, M. F. P., Waarsing, J. H., Jahr, H., Van Lieshout, E. M. M., Patka, P., Verhaar, J. A. N., Zadpoor, A. A., & Weinans, H.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2012-12-19
- Volume
- 31
- Issue
- 5
- Pages
- 792-799
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1968384518
- Cited by
- 271
- References
- 23
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.