Optimization of dispersive liquid–liquid microextraction of Co(II) and Fe(III) as their oxinate chelates and analysis by HPLC: Application for the simultaneous determination of Co(II) and Fe(III) in water samples
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
In this study, dispersive liquid–liquid microextraction method was used for the preconcentration and simultaneous determination of Co(II) and Fe(III) in water samples as their oxinate chelates. In dispersive liquid–liquid microextraction process, methanol and chloroform were used as disperser and extracting solvents, respectively, and the ligand 8‐hydroxy quinoline was used as a chelating agent for the extraction of Co(II) and Fe(III). HPLC was applied for the quantitation of the analytes after preconcentration. An experimental design, central composite design, coupled with response surface methodology was used for the optimization of the involved experimental parameters. In addition, the effect of various experimental parameters in the extraction was investigated using one variable at a time method. The calibration graphs were linear in the range of 20–4000 μg/L with the LODs of 3 μg/L for both analytes. The RSDs for six replicate measurements of 500 μg/L of Co 2+ and Fe 3+ were 3.3 and 4.1%, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Fattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Farajzadeh, M. A., Bahram, M., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.040 · Cited by 234
Self-citationFattahi, N., Samadi, S., Assadi, Y., & Hosseini, M. R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.002 · Cited by 178
Zhao, E., Zhao, W., Han, L., Jiang, S., & Zhou, Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.069 · Cited by 170
Chamsaz, M., Arbab-Zavar, M. H., & Nazari, S. (2003) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b303169a · Cited by 83
Farajzadeh, M. A., Vardast, M. R., & Bahram, M. (2009) · Chromatographia · doi:10.1365/s10337-008-0912-z · Cited by 36
Self-citation
Cited by
Arain, M. B., Yilmaz, E., & Soylak, M. (2016) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2016.10.005 · Cited by 168
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“4 mg L¡1 (1320) Co, Fe Water DLLME HPLC-UV 3 mg L¡1 (1321) Co, Fe, Ga, Pb, Se, Zn Water DLLME XRF 1.”
Ojeda, C. B., & Rojas, F. S. (2011) · Chromatographia · doi:10.1007/s10337-011-2124-1 · Cited by 69
Çabuk, H., Akyüz, M., & Ata, Ş. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200317 · Cited by 41
Metadata
- Authors
- Farajzadeh, M. A., Bahram, M., & Vardast, M. R.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2009-12
- Volume
- 32
- Issue
- 23-24
- Pages
- 4200-4212
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2120933838
- Cited by
- 32
- References
- 8
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.