Optically mediated nerve stimulation: Identification of injury thresholds
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background and Objective: Transient optical nerve stimulation is a promising new non‐contact, spatially precise, artifact‐free neural excitation technique useful in research and clinical settings. This study evaluates safety of this pulsed infrared laser technique by histopathologic examination of stimulated peripheral nerves. Study Design/Materials and Methods: Exposed rat sciatic nerves were functionally stimulated with the pulsed Holmium:YAG laser, previously validated as an effective tool for optical stimulation. Nerves were removed immediately and up to 2 weeks after stimulation and assessed histologically for thermal damage. Laser parameters studied include upper limits for radiant exposure, repetition rate, and duration of stimulation. Results: Radiant exposures with <1% probability of thermal tissue damage (0.66–0.70 J/cm 2) are significantly greater than radiant exposures required for reliable stimulation (0.34–0.48 J/cm 2). The upper limit for safe laser stimulation repetition rate occurs near 5 Hz. Maximum duration for constant low repetition rate stimulation (2 Hz) is ∼4 minutes with adequate tissue hydration. Conclusion: Results confirm that optical stimulation has the potential to become a powerful non‐contact clinical and research tool for brief nerve stimulation with low risk of nerve thermal damage. Lasers Surg. Med. 39:513–526, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Criteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240 · cited 1×
“Although systematic studies have defined the safe range of use for other modalities of nerve stimulation [3–7], no literature exists describing the optimal parameters for safe and effective stimulation using optical means.”
BackgroundAgnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185 · cited 1×
“Although systematic studies have defined the safe range of use for other modalities of nerve stimulation [3–7], no literature exists describing the optimal parameters for safe and effective stimulation using optical means.”
Background
Cited by
Biological effects and medical applications of infrared radiation
Tsai, S.-R., & Hamblin, M. R. (2017) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2017.04.014 · Cited by 477
Optical Stimulation of Neurons
C. Thompson, A., R. Stoddart, P., & Jansen, E. D. (2015) · Current Molecular Imaging · doi:10.2174/2211555203666141117220611 · Cited by 105
“Studies on the safety margins [58] found that that the threshold to stimulate tissue and corresponding 95% confidence ranges did not overlap with the radiant exposures found to cause damage, when stimulation was performed at rates between 2 – 8 Hz.”
BackgroundCombined optical and electrical stimulation of neural tissue in vivo
Duke, A. R., Cayce, J. M., Malphrus, J. D., Konrad, P., Mahadevan-Jansen, A., & Jansen, E. D. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3257230 · Cited by 76
Self-citationCompliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
Duke, A. R., Peterson, E., Mackanos, M. A., Atkinson, J., Tyler, D., & Jansen, E. D. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066006 · Cited by 45
Metadata
- Authors
- Wells, J. D., Thomsen, S., Whitaker, P., Jansen, E. D., Kao, C. C., Konrad, P. E., & Mahadevan‐Jansen, A.
- Venue
- Lasers in Surgery and Medicine
- Publisher
- Wiley
- Published
- 2007-07
- Volume
- 39
- Issue
- 6
- Pages
- 513-526
- ISSN
- 0196-8092 (ISSN-L)
- 1096-9101
- OpenAlex
- W2090518116
- Cited by
- 105
- References
- 2
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.