The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Abstract
Snapshot FLASH magnetic resonance imaging techniques have been developed to enable real‐time imaging of MR parameters. The first realization of the method is based on a 64 × 128 FLASH tomogram acquired within 200 ms, using improved MR system hardware conditions. The soft tissue contrast obtained in FLASH MRI almost disappears by using flip angles of less than 5° and repetition times of 3 ms. This work describes extensions of FLASH MRI placing conventional MR experiments before the whole imaging sequence. This creates images of any desired contrast without changing the measuring time. Examples of inversion‐recovery T1, spin‐echo T2, chemical‐shift‐selective, and spectroscopic FLASH MRI are presented. Further extensions to real‐time MRI of blood vessels, diffusion coefficients, combination with two‐dimensional MR spectroscopy experiments, and other nuclei are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Self-citation1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Self-citationNMR chemical shift imaging in three dimensions.
Brown, T. R., Kincaid, B. M., & Ugurbil, K. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.11.3523 · Cited by 1,039
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hanicke, W., & Merboldt, K.-D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90433-6 · Cited by 826
Self-citationA flow velocity zeugmatographic interlace for NMR imaging in humans
Moran, P. R. (1982) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(82)90170-9 · Cited by 745
Brooker, H. R. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90089-6 · Cited by 455
Sensitivity in Fourier transform NMR spectroscopy of slowly relaxing systems
Waugh, J. S. (1970) · Journal of Molecular Spectroscopy · doi:10.1016/0022-2852(70)90205-5 · Cited by 164
Mansfield, P., & Chapman, B. L. W. (1986) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/19/7/008 · Cited by 154
Instant images of the body by magnetic resonance
Richard, I. L. P., & Rzedzian, R. R. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050607 · Cited by 112
Cited by
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Principles and applications of balanced SSFP techniques
Scheffler, K., & Lehnhardt, S. (2003) · European Radiology · doi:10.1007/s00330-003-1957-x · Cited by 714
Parker, G. J. M., Roberts, C., Macdonald, A., Buonaccorsi, G. A., Cheung, S., Buckley, D. L., Jackson, A., Watson, Y., Davies, K., & Jayson, G. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21066 · Cited by 660
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Metadata
- Authors
- Haase, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1990-01
- Volume
- 13
- Issue
- 1
- Pages
- 77-89
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2130872658
- Cited by
- 693
- References
- 12
- FWCI
- 44.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.