Specific MR imaging of human lymphocytes by monoclonal antibody‐guided dextran‐magnetite particles
The DOI matches its Crossref record.
Abstract
Human lymphocytes were labeled with biotinylated anti‐lymphocyte‐directed monoclonal antibodies, to which streptavidin and subsequently biotinylated dextran‐magnetite particles were coupled. This labeling resulted in a strong and selective negative contrast enhancement of lymphocyte suspensions at 2.0 T, caused predominantly by the specific increase of R 2 with a small but significant specific increase of R 2. The R 1 was found to decrease with increasing field strength. The immunolabeling procedure described here may be used for the selective signal depletion of target cells in MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Magnetic nanoparticles in MR imaging and drug delivery
Sun, C., Lee, J. S. H., & Zhang, M. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.018 · Cited by 2,594
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Mahmoudi, M., Sant, S., Wang, B., Laurent, S., & Sen, T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.05.006 · Cited by 1,881
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Self-citationRecent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
A detailed examination of boronic acid–diol complexation
Springsteen, G., & Wang, B. (2002) · Tetrahedron · doi:10.1016/s0040-4020(02)00489-1 · Cited by 1,461
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Inorganic nanoparticles for cancer imaging and therapy
Huang, H.-C., Barua, S., Sharma, G., Dey, S. K., & Rege, K. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.06.004 · Cited by 618
Kohler, N., Sun, C., Wang, J., & Zhang, M. (2005) · Langmuir · doi:10.1021/la0503451 · Cited by 579
Lipid‐based nanoparticles for contrast‐enhanced MRI and molecular imaging
Mulder, W. J. M., Strijkers, G. J., van Tilborg, G. A. F., Griffioen, A. W., & Nicolay, K. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1011 · Cited by 535
Nanotheranostics for personalized medicine
Mura, S., & Couvreur, P. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.06.006 · Cited by 527
Tracking immune cells in vivo using magnetic resonance imaging
Ahrens, E. T., & Bulte, J. W. M. (2013) · Nature Reviews Immunology · doi:10.1038/nri3531 · Cited by 491
Self-citationKohler, N., Fryxell, G. E., & Zhang, M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049195r · Cited by 466
New Generation of Multifunctional Nanoparticles for Cancer Imaging and Therapy
Park, K., Lee, S., Kang, E., Kim, K., Choi, K., & Kwon, I. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801655 · Cited by 432
In vivo MRI cell tracking: clinical studies
Bulte, J. W. M. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.3107 · Cited by 430
Self-citationMahmoudi, M., Hosseinkhani, H., Hosseinkhani, M., Boutry, S., Simchi, A., Journeay, W. S., Subramani, K., & Laurent, S. (2011) · Chemical Reviews · doi:10.1021/cr1001832 · Cited by 418
Hinds, K. A., Hill, J. M., Shapiro, E. M., Laukkanen, M. O., Silva, A. C., Combs, C. A., Varney, T. R., Balaban, R. S., Koretsky, A. P., & Dunbar, C. E. (2003) · Blood · doi:10.1182/blood-2002-12-3669 · Cited by 401
Sun, C., Sze, R., & Zhang, M. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30781 · Cited by 373
Artemov, D., Mori, N., Okollie, B., & Bhujwalla, Z. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10406 · Cited by 351
Magnetically labeled cells can be detected by MR imaging
Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070140 · Cited by 336
Progress in functionalization of magnetic nanoparticles for applications in biomedicine
Berry, C. C. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224003 · Cited by 336
Detection of Single Mammalian Cells by High-Resolution Magnetic Resonance Imaging
Dodd, S. J., Williams, M., Suhan, J. P., Williams, D. S., Koretsky, A. P., & Ho, C. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77182-1 · Cited by 265
Tracking stem cells using magnetic nanoparticles
Cromer Berman, S. M., Walczak, P., & Bulte, J. W. M. (2011) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.140 · Cited by 265
Self-citationArsalani, N., Fattahi, H., & Nazarpoor, M. (2010) · Express Polymer Letters · doi:10.3144/expresspolymlett.2010.42 · Cited by 259
Ahrens, E. T., Feili‐Hariri, M., Xu, H., Genove, G., & Morel, P. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10465 · Cited by 168
Molecular magnetic resonance imaging with targeted contrast agents
Artemov, D. (2003) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10660 · Cited by 168
“This approach was used for imaging leukocytes with a MAb against the leukocyte common antigen conjugated to SPIOparticles [Bulte et al., 1992].”
Method
Metadata
- Authors
- Bulte, J. W. M., Hoekstra, Y., Kamman, R. L., Magin, R. L., Webb, A. G., Briggs, R. W., Gwan Go, K., Hulstaert, C. E., Miltenyi, S., Hauw The, T., & De Leij, L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1992-05
- Volume
- 25
- Issue
- 1
- Pages
- 148-157
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2108200886
- Cited by
- 148
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.