The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Intravascular susceptibility contrast mechanisms in tissues
Abstract
The factors affecting the rate of loss of transverse magnetization in gradient echo and spin‐echo pulse sequences have been quantified using computer modeling for media containing arrays of susceptibility variations. The results are particularly relevant for describing the signal losses that occur in tissues containing capillaries of altered intrinsic susceptibility from the administration of exogenous contrast agents or arising from changes in blood oxygenation. The precise magnitudes and relationship of gradient echo and spin‐echo decay rates depend on geometrical factors such as the sizes and spacings of the inhomogeneities, the rate of water diffusion, field strength, and echo times. The conventional separation of contributions to transverse decay rates arising from so‐called static field effects and diffusion is shown to be inappropriate for many situations of practical interest because diffusion introduces a motional averaging of the static field even in gradient echo sequences. The result of diffusion in some regimes is to reduce the decay rate from field inhomogeneities in gradient echo sequences, so that T 2* is longer in media such as tissue where water diffuses reasonably rapidly, than would be the case for stationary nuclei. The effects of different types of contrast agent and the implications for functional imaging based on the effects of deoxyhemoglobin in brain tissue are considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Probability, Random Variables, and Stochastic Processes
Miller, I. (1966) · Technometrics · doi:10.1080/00401706.1966.10490365 · Cited by 8,452
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
The principles of nuclear magnetism
(1961) · Nuclear Physics · doi:10.1016/0029-5582(61)91110-5 · Cited by 4,053
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
Exchange Narrowing in Paramagnetic Resonance
Anderson, P. W., & Weiss, P. R. (1953) · Reviews of Modern Physics · doi:10.1103/revmodphys.25.269 · Cited by 1,289
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Passage of Molecules Through Capillary Walls
Pappenheimer, J. R. (1953) · Physiological Reviews · doi:10.1152/physrev.1953.33.3.387 · Cited by 954
Nuclear Magnetic Resonance Transverse Relaxation Times of Water Protons in Skeletal Muscle
Hazlewood, C. F., Chang, D. C., Nichols, B. L., & Woessner, D. E. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85937-0 · Cited by 478
Susceptibility artefacts in NMR imaging
Lüdeke, K. M., Röschmann, P., & Tischler, R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90397-2 · Cited by 445
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Gillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
Gadolinium-DTPA as a contrast agent in MRI: initial clinical experience in 20 patients
Carr, D., Brown, J., Bydder, G., Steiner, R., Weinmann, H., Speck, U., Hall, A., & Young, I. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.143.2.215 · Cited by 299
Transverse relaxivity of particulate MRI contrast media: From theories to experiments
Muller, R. N., Gillis, P., Moiny, F., & Roch, A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220203 · Cited by 171
Studies of diffusion in random fields produced by variations in susceptibility
Majumdar, S., & Gore, J. C. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90155-2 · Cited by 161
Self-citationEffects of susceptibility variations on NMR measurements of diffusion
Zhong, J., Kennan, R. P., & Gore, J. C. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90217-h · Cited by 128
Self-citationBrown, R. J. S. (1961) · Physical Review · doi:10.1103/physrev.121.1379 · Cited by 114
Transverse relaxation rate enhancement caused by magnetic particulates
Hardy, P., & Henkelman, R. M. (1989) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(89)90549-3 · Cited by 92
Intravoxel incoherent motion imaging using spin echoes
Bihan, D. L., & Turner, R. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190206 · Cited by 77
Majumdar, S., Zoghbi, S., Pope, C. F., et al. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090205 · Cited by 66
Majumdar, S., Zoghbi, S. S., & Gore, J. C. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100302 · Cited by 62
Self-citation
Cited by
Magnetic Nanoparticles: Surface Effects and Properties Related to Biomedicine Applications
Issa, B., Obaidat, I., Albiss, B., & Haik, Y. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141121266 · Cited by 1,245
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
The neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Metadata
- Authors
- Kennan, R. P., Zhong, J., & Gore, J. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-01
- Volume
- 31
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2079716456
- Cited by
- 524
- References
- 24
- FWCI
- 27.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.