Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 421

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

BOLD Based Functional MRI at 4 Tesla Includes a Capillary Bed Contribution: Echo‐Planar Imaging Correlates with Previous Optical Imaging Using Intrinsic Signals

Menon, Ravi S., Ogawa, Seiji, Hu, Xiaoping, Strupp, John P., Anderson, Peter, Uǧurbil, Kǎmil·1995·Magnetic Resonance in Medicine

Abstract

We show that the EPI time course in functional MR imaging at 4 Tesla displays a multiphasic response in response to photic stimulation. Focal areas of gray matter display an initial negative change in signal intensity that reaches a maximum of 1 % about 2 s after the onset of photic stimulation. This component then changes sign, reaching a positive maximum about 5 s after the onset of the stimulus. Other areas, including those where draining veins are visible, show only a positive signal change, reaching a maximum of about 6% after the onset of the visual stimulus. These time constants are in very good agreement with published data obtained with intrinsic optical mapping techniques, where a deoxygenation phase has been shown to occur in functionally specific cortical columns, followed by an increase in blood volume which is more distributed in nature. Thus, we believe there is strong evidence that a sensitivity to capillary oxygenation state is present in high S/N functional MR images obtained with EPI at 4 T.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910330323

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 421

Metadata

Authors
Menon, R. S., Ogawa, S., Hu, X., Strupp, J. P., Anderson, P., & Uǧurbil, K.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1995-03
Volume
33
Issue
3
Pages
453-459
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1997232604
Cited by
421
References
5
FWCI
25.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.