Analytical expressions for the NMR apparent diffusion coefficients in an anisotropic system and a simplified method for determining fiber orientation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
NMR measurements of anisotropic diffusion were studied using a three‐dimensional random‐walk model. It was found that the apparent diffusion coefficient can be expressed in a canonical form as the product of a diagonal matrix, an orthonormal rotation matrix, and a vector representing the encoding magnetic field gradient. The diffusion coefficient can be interpreted as the sum of the corresponding coefficients measured along the principal diffusion axes, weighted by the squares of the directional cosines of the encoding direction with respect to the principal axes. The analysis revealed that determining the orientation of anisotropy, in a cylindrically symmetric system, requires a minimum of four diffusion measurements. A special pulse sequence which minimized gradient cross‐terms and possible restricted diffusion effects was used to characterize diffusion anisotropy in cut chicken gizzards. Diffusion coefficients parallel to the muscle fibers were found to be approximately two to three times larger than those in the transverse direction. Furthermore, the method was successful in detecting the angular change when the sample was rotated by 30°. Results indicate that the proposed approach to measure fiber orientation is valid and may be used to improve the time efficiency of diffusion anisotropy measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
MR color mapping of myelin fiber orientation
Douek, P., Turner, R., Pekar, J., Patronas, N., & Bihan, D. L. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199111000-00003 · Cited by 274
Cited by
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Basser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
A simplified method to measure the diffusion tensor from seven MR images
Basser, P. J., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390610 · Cited by 583
Characterization of anisotropy in high angular resolution diffusion‐weighted MRI
Frank, L. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10156 · Cited by 510
Measurement of fiber orientation distributions using high angular resolution diffusion imaging
Anderson, A. W. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20667 · Cited by 463
Scollan, D. F., Holmes, A., Winslow, R., & Forder, J. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.6.h2308 · Cited by 457
Özarslan, E., & Mareci, T. H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10596 · Cited by 423
Anisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
In vivo three-dimensional reconstruction of rat brain axonal projections by diffusion tensor imaging
Xue, R., van Zijl, P. C. M., Crain, B. J., Solaiyappan, M., & Mori, S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1123::aid-mrm17>3.0.co;2-h · Cited by 386
Self-citationMagnetic resonance myocardial fiber-orientation mapping with direct histological correlation
Hsu, E. W., Muzikant, A. L., Matulevicius, S. A., Penland, R. C., & Henriquez, C. S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.5.h1627 · Cited by 386
Self-citationThe physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
Basser, P. J., & Pajevic, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;2-o · Cited by 318
Shimony, J. S., McKinstry, R. C., Akbudak, E., Aronovitz, J. A., Snyder, A. Z., Lori, N. F., Cull, T. S., & Conturo, T. E. (1999) · Radiology · doi:10.1148/radiology.212.3.r99au51770 · Cited by 315
Magnetic resonance elastography of skeletal muscle
Dresner, M. A., Rose, G. H., Rossman, P. J., Muthupillai, R., Manduca, A., & Ehman, R. L. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200102)13:2<269::aid-jmri1039>3.0.co;2-1 · Cited by 307
Towards multimodal atlases of the human brain
Toga, A. W., Thompson, P. M., Mori, S., Amunts, K., & Zilles, K. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn2012 · Cited by 305
Self-citationDell'Acqua, F., Simmons, A., Williams, S. C. R., & Catani, M. (2013) · Human Brain Mapping · doi:10.1002/hbm.22080 · Cited by 295
Diffusion MRI: Precision, accuracy and flow effects
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080706 · Cited by 211
A Model-Based Deconvolution Approach to Solve Fiber Crossing in Diffusion-Weighted MR Imaging
Dell'Acqua, F., Rizzo, G., Scifo, P., Clarke, R. A., Scotti, G., & Fazio, F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.888830 · Cited by 194
“More specifically, assuming a single-tensor model, follows the relation [23]:”
BackgroundLeergaard, T. B., White, N. S., de Crespigny, A., Bolstad, I., D'Arceuil, H., Bjaalie, J. G., & Dale, A. M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0008595 · Cited by 179
“An axially symmetric tensor model [54] was chosen for the single fiber response function with perpendicular (lH =l2 =l3 = 4.”
MethodGeneralized scalar measures for diffusion MRI using trace, variance, and entropy
Özarslan, E., Vemuri, B. C., & Mareci, T. H. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20411 · Cited by 166
“[14], [16], [19], and [20] for higher-rank tensors.”
Lori, N. F., Akbudak, E., Shimony, J. S., Cull, T. S., Snyder, A. Z., Guillory, R. K., & Conturo, T. E. (2002) · NMR in Biomedicine · doi:10.1002/nbm.779 · Cited by 164
Classification and quantification of neuronal fiber pathways using diffusion tensor MRI
Ding, Z., Gore, J. C., & Anderson, A. W. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10415 · Cited by 159
Effect of inaccurate b-values from imaging gradients on intravoxel incoherent motion
Rashid, I. A., Szczepankiewicz, F., Gunnlaugsson, A., Olsson, L. E., & Brynolfsson, P. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30579 · Cited by 8
Metadata
- Authors
- Hsu, E. W., & Mori, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1995-08
- Volume
- 34
- Issue
- 2
- Pages
- 194-200
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2094446283
- Cited by
- 112
- References
- 3
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.