CoChat

Evidence for the exchange of arterial spin‐labeled water with tissue water in rat brain from diffusion‐sensitized measurements of perfusion

Silva, Afonso C., Williams, Donald S., Koretsky, Alan P. · 1997 · Magnetic Resonance in Medicine
Cited by 103

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The extraction fraction of vascular water in rat brain is investigated by means of diffusion measurements of arterial spin labeled water at varying cerebral blood flow (CBF) values. The apparent diffusion coefficient (ADC) of the difference of the proton magnetization signal in the brain acquired with and without continuous arterial spin labeling is modeled to provide a measure of the amount of arterial water in tissue and vasculature and thus of the extraction fraction. The tissue and vascular portion of the arterial spin labeled water are differentiated based on their diffusion characteristics in a manner analogous to the intravoxel incoherent motion (IVIM) method. The amount of labeled arterial water that exchanges with tissue water is determined by estimating the fraction of the total signal that is associated with the slow‐decaying component of a biexponential fit to the normalized difference signal between the magnetization of brain tissue acquired with and without arterial spin labeling. The results indicate that, at normal CBF (1.15 ± 0.21 ml g‐1 min‐1), about 90% of the arterial spin labeled water diffuses with an ADC of (1.21 ± 0.37) 10‐3 mm 2 s‐1), which is equal to tissue. At high CBF, an increasing fraction of the labeling water has a fast‐pseudo‐diffusion coefficient due to a decrease in water extraction fractions. The results also show that the contribution of vascular water to the measurement of perfusion by techniques that use endogenous water as a tracer can be efficiently eliminated by the use of diffusion sensitizing gradients with small effective b values (b ≈ 20 s/mm 2), enabling these techniques to monitor true changes in tissue perfusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910380211

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 103

Metadata

Authors
Silva, A. C., Williams, D. S., & Koretsky, A. P.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1997-08
Volume
38
Issue
2
Pages
232-237
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2119025182
Cited by
103
References
4
FWCI
3.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evidence for the exchange of arterial spin‐labeled water with tissue water in rat brain from diffusion‐sensitized measurements of perfusion. https://app.cochat.ai/papers/10.1002/mrm.1910380211
The paper
Silva, A. C., Williams, D. S., & Koretsky, A. P. (1997). Evidence for the exchange of arterial spin‐labeled water with tissue water in rat brain from diffusion‐sensitized measurements of perfusion. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910380211

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.