The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Recording of EEG during fMRI experiments: Patient safety
Abstract
The acquisition of electroencephalograms (EEG) during functional magnetic resonance imaging (fMRI) experiments raises important practical issues of patient safety. The presence of electrical wires connected to the patient in rapidly changing magnetic fields results in currents flowing through the patient due to induced electromotive forces (EMF), by three possible mechanisms: fixed loop in rapidly changing gradient fields; fixed loop in a RF electromagnetic field; moving loop in the static magnetic field. RF‐induced EMFs were identified as the most important potential hazard. We calculated the minimum value of current‐limiting resistance to be fitted in each EEG electrode lead for a representative worst case loop, and measured RF magnetic field intensity and heating in a specific type of current‐limiting resistors. The results show that electrode resistance should be ≥13 kΩ for our setup. The methodology presented is general and can be useful for other centers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
Hayes, C. E., Edelstein, W. A., Schenck, J. F., et al. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90257-4 · Cited by 766
Biomedical magnetic resonance technology
Chen, C.-N., & Hoult, D. I. (1989) · Cited by 407
Monitoring the patient's EEG during echo planar MRI
Ives, J. R., Warach, S., Schmitt, F., Edelman, R. R., & Schomer, D. L. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90156-p · Cited by 398
EEG-triggered echo-planar functional MRI in epilepsy
Warach, S., Ives, J. R., Schlaug, G., Patel, M. R., Darby, D. G., Thangaraj, V., Edelman, R. R., & Schomer, D. L. (1996) · Neurology · doi:10.1212/wnl.47.1.89 · Cited by 254
Simultaneous functional magnetic resonance imaging and electrophysiological recording
Huang‐Hellinger, F. R., Breiter, H. C., Mccormack, G. L., Cohen, M. S., Kwong, K. K., Sutton, J. P., Savoy, R. L., Weisskoff, R. M., Davis, T. L., Baker, J. R., et al. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030103 · Cited by 127
The heating of metal electrodes during rapid-rate magnetic stimulation: a possible safety hazard
Roth, B. J., Pascual‐Leone, Á., Cohen, L. G., & Hallett, M. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90077-o · Cited by 94
Electrocardiographic gating and monitoring in NMR imaging
Wendt, R. E., Rokey, R., Vick, G. W., & Johnston, D. L. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90528-0 · Cited by 67
Patient Monitoring during Magnetic Resonance Imaging
Roth, J. L., Nugent, M., Gray, J. E., Julsrud, P. R., Berquist, T. H., Sill, J. C., & Kispert, D. B. (1985) · Anesthesiology · doi:10.1097/00000542-198501000-00018 · Cited by 61
Cited by
Presurgical evaluation of epilepsy
Rosenow, F. (2001) · Brain · doi:10.1093/brain/124.9.1683 · Cited by 1,669
A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI
Allen, P. J., Josephs, O., & Turner, R. (2000) · NeuroImage · doi:10.1006/nimg.2000.0599 · Cited by 1,301
Self-citationAllen, P. J., Polizzi, G., Krakow, K., Fish, D. R., & Lemieux, L. (1998) · NeuroImage · doi:10.1006/nimg.1998.0361 · Cited by 912
Self-citationLonsdorf, T. B., Menz, M. M., Andreatta, M., Fullana, M. A., Golkar, A., Haaker, J., Heitland, I., Hermann, A., Kuhn, M., Kruse, O., et al. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2017.02.026 · Cited by 837
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Correlates of alpha rhythm in functional magnetic resonance imaging and near infrared spectroscopy
Moosmann, M., Ritter, P., Krastel, I., Brink, A., Thees, S., Blankenburg, F., Taskin, B., Obrig, H., & Villringer, A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00344-6 · Cited by 594
Removal of FMRI environment artifacts from EEG data using optimal basis sets
Niazy, R. K., Beckmann, C. F., Iannetti, G. D., Brady, J. M., & Smith, S. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.06.067 · Cited by 567
Cortical network functional connectivity in the descent to sleep
Larson-Prior, L. J., Zempel, J. M., Nolan, T. S., Prior, F. W., Snyder, A. Z., & Raichle, M. E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900924106 · Cited by 450
Auditory Processing across the Sleep-Wake Cycle
Portas, C. M., Krakow, K., Allen, P., Josephs, O., Armony, J. L., & Frith, C. D. (2000) · Neuron · doi:10.1016/s0896-6273(00)00169-0 · Cited by 392
Self-citationTian, L., Zimmerman, B., Akhtar, A., Yu, K. J., Moore, M., Wu, J., Larsen, R. J., Lee, J. W., Li, J., Liu, Y., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0347-x · Cited by 393
Correlating the alpha rhythm to BOLD using simultaneous EEG/fMRI: Inter-subject variability
Gonçalves, S. I., de Munck, J. C., Pouwels, P. J. W., Schoonhoven, R., Kuijer, J. P. A., Maurits, N. M., Hoogduin, J. M., Van Someren, E. J. W., Heethaar, R. M., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.062 · Cited by 356
Applications of fMRI in translational medicine and clinical practice
Matthews, P. M., Honey, G. D., & Bullmore, E. T. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1929 · Cited by 322
EEG-triggered functional MRI of interictal epileptiform activity in patients with partial seizures
Krakow, K., Woermann, F. G., Symms, M. R., Allen, P. J., Lemieux, L., Barker, G. J., Duncan, J. S., & Fish, D. R. (1999) · Brain · doi:10.1093/brain/122.9.1679 · Cited by 305
Self-citationRitter, P., & Villringer, A. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.008 · Cited by 294
Acquiring simultaneous EEG and functional MRI
Goldman, R. I., Stern, J. M., Engel, J., & Cohen, M. S. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00456-9 · Cited by 284
Salek-Haddadi, A., Diehl, B., Hamandi, K., Merschhemke, M., Liston, A., Friston, K., Duncan, J. S., Fish, D. R., & Lemieux, L. (2006) · Brain Research · doi:10.1016/j.brainres.2006.02.098 · Cited by 280
Self-citationCombining EEG and fMRI: A multimodal tool for epilepsy research
Gotman, J., Kobayashi, E., Bagshaw, A. P., Bénar, C., & Dubeau, F. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20577 · Cited by 280
Lemieux, L., Salek-Haddadi, A., Josephs, O., Allen, P., Toms, N., Scott, C., Krakow, K., Turner, R., & Fish, D. R. (2001) · NeuroImage · doi:10.1006/nimg.2001.0853 · Cited by 277
Self-citationEEG–fMRI of idiopathic and secondarily generalized epilepsies
Hamandi, K., Salek-Haddadi, A., Laufs, H., Liston, A., Friston, K., Fish, D. R., Duncan, J. S., & Lemieux, L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.016 · Cited by 274
Self-citationThe hemodynamic response of the alpha rhythm: An EEG/fMRI study
de Munck, J. C., Gonçalves, S. I., Huijboom, L., Kuijer, J. P. A., Pouwels, P. J. W., Heethaar, R. M., & Lopes da Silva, F. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.022 · Cited by 260
Quality of EEG in simultaneous EEG-fMRI for epilepsy
Bénar, C.-G., Aghakhani, Y., Wang, Y., Izenberg, A., Al-Asmi, A., Dubeau, F., & Gotman, J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00383-8 · Cited by 259
Multimodal Functional Neuroimaging: Integrating Functional MRI and EEG/MEG
He, B., & Liu, Z. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008233 · Cited by 171
“fMRI pulses [159], EEG lead design and placement [155], [160], [161], cable wiring [152], signal transmitting [153], [162], subject comfort and safety [155], [163], etc.”
BackgroundElectrophysiological correlates of the BOLD signal for EEG-informed fMRI
Murta, T., Leite, M., Carmichael, D. W., Figueiredo, P., & Lemieux, L. (2015) · Human Brain Mapping · doi:10.1002/hbm.22623 · Cited by 165
“, 2008]; and additional safety concerns [Lemieux et al., 1997].”
Self-citationvan Well, S., Visser, R. M., Scholte, H. S., & Kindt, M. (2012) · Cognitive, Affective, & Behavioral Neuroscience · doi:10.3758/s13415-012-0089-7 · Cited by 75
Neuner, I., Arrubla, J., Felder, J., & Shah, N. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.048 · Cited by 48
Solana, A. B., Hernández-Tamames, J. A., Manzanedo, E., García-Álvarez, R., Zelaya, F. O., & del Pozo, F. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.03.008 · Cited by 11
Metadata
- Authors
- Lemieux, L., Allen, P. J., Franconi, F., Symms, M. R., & Fish, D. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-12
- Volume
- 38
- Issue
- 6
- Pages
- 943-952
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2154670640
- Cited by
- 311
- References
- 8
- FWCI
- 10.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.