The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Model‐free arterial spin labeling quantification approach for perfusion MRI
Open accessAbstract
In this work a model‐free arterial spin labeling (ASL) quantification approach for measuring cerebral blood flow (CBF) and arterial blood volume (aBV) is proposed. The method is based on the acquisition of a train of multiple images following the labeling scheme. Perfusion is obtained using deconvolution in a manner similar to that of dynamic susceptibility contrast (DSC) MRI. Local arterial input functions (AIFs) can be estimated by subtracting two perfusion‐weighted images acquired with and without crusher gradients, respectively. Furthermore, by knowing the duration of the bolus of tagged arterial blood, one can estimate the aBV on a voxel‐by‐voxel basis. The maximum of the residue function obtained from the deconvolution of the tissue curve by the AIF is a measure of CBF after scaling by the locally estimated aBV. This method provides averaged gray matter (GM) perfusion values of 38 ± 2 ml/min/100 g and aBV of 0.93% ± 0.06%. The average CBF value is 10% smaller than that obtained on the same data set using the standard general kinetic model (42 ± 2 ml/min/100 g). Monte Carlo simulations were performed to compare this new methodology with parametric fitting by the conventional model. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
The Levenberg-Marquardt algorithm: Implementation and theory
Moré, J. J. (1978) · Lecture Notes in Mathematics · doi:10.1007/bfb0067700 · Cited by 5,773
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Numerical recipes in C (2nd ed.): the art of scientific computing
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1992) · Cambridge University Press eBooks · Cited by 1,156
CEREBRAL BLOOD FLOW, BLOOD VOLUME AND OXYGEN UTILIZATION: NORMAL VALUES AND EFFECT OF AGE
LEENDERS, K. L., PERANI, D., LAMMERTSMA, A. A., HEATHER, J. D., BUCKINGHAM, P., JONES, T., HEALY, M. J. R., GIBBS, J. M., WISE, R. J. S., HATAZAWA, J., et al. (1990) · Brain · doi:10.1093/brain/113.1.27 · Cited by 1,093
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
WET, a T1- and B1-Insensitive Water-Suppression Method for in Vivo Localized 1H NMR Spectroscopy
Ogg, R. J., Kingsley, R. B., & Taylor, J. S. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1048 · Cited by 732
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Self-citationWu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
Luh, W.-M., Wong, E. C., Bandettini, P. A., & Hyde, J. S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1246::aid-mrm22>3.0.co;2-n · Cited by 506
Mr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Ye, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370215 · Cited by 294
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Self-citationKim, S., & Tsekos, N. V. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370321 · Cited by 247
Comparison of the dependence of blood R2 and R on oxygen saturation at 1.5 and 4.7 Tesla
Silvennoinen, M. J., Clingman, C. S., Golay, X., Kauppinen, R. A., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10355 · Cited by 219
Self-citationFlow Territory Mapping of the Cerebral Arteries With Regional Perfusion MRI
Hendrikse, J., van der Grond, J., Lu, H., van Zijl, P. C. M., & Golay, X. (2004) · Stroke · doi:10.1161/01.str.0000120312.26163.ec · Cited by 164
Self-citationCalamante, F., Gadian, D. G., & Connelly, A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10643 · Cited by 142
Local cerebral blood volume response to carbon dioxide in man.
Greenberg, J. H., Alavi, A. A., Reivich, M., Kuhl, D., & Uzzell, B. P. (1978) · Circulation Research · doi:10.1161/01.res.43.2.324 · Cited by 129
Accurate measurement of T1in vivo in less than 3 seconds using echo‐planar imaging
Gowland, P. A., & Mansfield, P. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300312 · Cited by 115
Two-Compartment Exchange Model for Perfusion Quantification Using Arterial Spin Tagging
Zhou, J., Wilson, D. A., Ulatowski, J. A., Traystman, R. J., & van Zijl, P. C. M. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200104000-00013 · Cited by 113
Lawrence, K. S., Frank, J. A., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<440::aid-mrm15>3.0.co;2-6 · Cited by 108
EPISTAR MRI: Multislice mapping of cerebral blood flow
Edelman, R. R., & Chen, Q. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400603 · Cited by 101
An, H., & Lin, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10257 · Cited by 90
Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI
Vonken, E.-J. P. A., Beekman, F. J., Bakker, C. J. G., & Viergever, M. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199902)41:2<343::aid-mrm19>3.0.co;2-t · Cited by 89
Local cerebral blood volume response to carbon dioxide in man.
HGreenberg, J., AAlavi, MReivich, DKuhl, & BUzzell (1978) · Circulation Research · Cited by 70
Hendrikse, J., Lu, H., van der Grond, J., van Zijl, P. C. M., & Golay, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10525 · Cited by 67
Self-citationPharmacological Applications of Magnetic Resonance Imaging
Salmeron, B. J., Stein, E. A., Stein, A. E. A., & PhD (2025) · Psychopharmacology Bulletin · doi:10.64719/pb.4234 · Cited by 61
Effect of Gossypol on Cultured TM3 Leydig and TM4 Sertoli Cells: 31P and 23Na NMR Study
Hansen, L. L., & Jaroszewski, J. W. (1996) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199604)9:2<79::aid-nbm399>3.0.co;2-4 · Cited by 9
Cited by
Applications of arterial spin labeled MRI in the brain
Detre, J. A., Rao, H., Wang, D. J. J., Chen, Y. F., & Wang, Z. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23581 · Cited by 326
Chronic pain: lost inhibition?
Henderson, L. A., Peck, C. C., Petersen, E. T., Rae, C. D., Youssef, A. M., Reeves, J. M., Wilcox, S. L., Akhter, R., Murray, G. M., & Gustin, S. M. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.0174-13.2013 · Cited by 180
Effects of working memory training on functional connectivity and cerebral blood flow during rest
Takeuchi, H., Taki, Y., Nouchi, R., Hashizume, H., Sekiguchi, A., Kotozaki, Y., Nakagawa, S., Miyauchi, C. M., Sassa, Y., & Kawashima, R. (2013) · Cortex · doi:10.1016/j.cortex.2012.09.007 · Cited by 162
Youssef, A. M., Gustin, S. M., Nash, P. G., Reeves, J. M., Petersen, E. T., Peck, C. C., Murray, G. M., & Henderson, L. A. (2014) · Pain · doi:10.1016/j.pain.2013.11.008 · Cited by 92
Self-citationEffects of Fast Simple Numerical Calculation Training on Neural Systems
Takeuchi, H., Nagase, T., Taki, Y., Sassa, Y., Hashizume, H., Nouchi, R., & Kawashima, R. (2016) · Neural Plasticity · doi:10.1155/2016/5940634 · Cited by 5
Metadata
- Authors
- Petersen, E. T., Lim, T., & Golay, X.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-01-13
- Volume
- 55
- Issue
- 2
- Pages
- 219-232
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2057746943
- Cited by
- 305
- References
- 36
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.