The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo
Open accessAbstract
Brain water proton (1 H 2 O) longitudinal relaxation time constants (T1) were obtained from three healthy individuals at magnetic field strengths (B0) of 0.2 Tesla (T), 1.0T, 1.5T, 4.0T, and 7.0T. A 5‐mm midventricular axial slice was sampled using a modified Look‐Locker technique with 1.5 mm in‐plane resolution, and 32 time points post‐adiabatic inversion. The results confirmed that for most brain tissues, T1 values increased by more than a factor of 3 between 0.2T and 7T, and over this range were well fitted by T1 (s) = 0.583(B0)0.382, T1(s) = 0.857(B0)0.376, and T1(s) = 1.35(B0)0.340 for white matter (WM), internal GM, and blood 1 H 2 O, respectively. The ventricular cerebrospinal fluid (CSF) 1 H 2 O T1 value did not change with B0, and its average value (standard deviation (SD)) across subjects and magnetic fields was 4.3 (±0.2) s. The tissue 1/T1 values at each field were well correlated with the macromolecular mass fraction, and to a lesser extent tissue iron content. The field‐dependent increases in 1 H 2 O T1 values more than offset the well‐known decrease in typical MRI contrast reagent (CR) relaxivity, and simulations predict that this leads to lower CR concentration detection thresholds with increased magnetic field. Magn Reson Med 57:308–318, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
The effect of age on the non-haemin iron in the human brain
Hallgren, B., & Sourander, P. (1958) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1958.tb12607.x · Cited by 1,427
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citationLanthanide( III ) chelates for NMR biomedical applications
Aime, S., Botta, M., Fasano, M., & Terreno, E. (1998) · Chemical Society Reviews · doi:10.1039/a827019z · Cited by 710
Silver, M. S., Joseph, R. I., & Hoult, D. I. (1985) · Physical Review A · doi:10.1103/physreva.31.2753 · Cited by 400
In vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394
Self-citationImaging at high magnetic fields: initial experiences at 4 T.
Uǧurbil, K., Garwood, M., Ellermann, J., Hendrich, K. S., Hinke, R. M., Hu, X. P., Kim, S. G., Menon, R. S., Merkle, H., & Ogawa, S. (1993) · PubMed · Cited by 282
Self-citationGelman, N., Ewing, J. R., Gorell, J. M., Spickler, E. M., & Solomon, E. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<71::aid-mrm1011>3.0.co;2-2 · Cited by 268
Fischer, H. W., Rinck, P. A., van Haverbeke, Y., & Muller, R. N. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160212 · Cited by 176
Li, X., Rooney, W. D., & SPRINGER, C. S. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20684 · Cited by 154
Self-citationFatouros, P. P., Marmarou, A., Kraft, K. A., Inao, S., & Schwarz, F. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170212 · Cited by 145
A fast 3D Look-Locker method for volumetric T1 mapping
Henderson, E., McKinnon, G. C., Lee, T.-Y., & Rutt, B. K. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00025-9 · Cited by 144
SQUID‐detected MRI at 132 μT with T1‐weighted contrast established at 10 μT–300 mT
Lee, S. K., Möβle, M., Myers, W., Kelso, N., Trabesinger, A. H., Pines, A., & Clarke, J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20316 · Cited by 139
Magnetic relaxation in blood and blood clots
Bryant, R. G., Marill, K. A., Blackmore, C. C., & Francis, C. W. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130112 · Cited by 136
Age‐related changes in Brain T1 are correlated with iron concentration
Ogg, R. J., & Steen, R. G. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400516 · Cited by 123
Labadie, C., Lee, J. H., Vétek, G., & SPRINGER, C. S. J. (1994) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1994.1109 · Cited by 119
Self-citationMiller, D., Johnson, G., Tofts, P. S., MacManus, D. G., & McDonald, W. I. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910110307 · Cited by 115
Self-citationAn MRI phantom material for quantitative relaxometry
Kraft, K. A., Fatouros, P. P., Clarke, G. D., & Kishore, P. R. S. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050606 · Cited by 109
Gembris, D., Taylor, J. G., Schor, S., Frings, W., Suter, D., & Posse, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<237::aid-mrm10>3.0.co;2-5 · Cited by 108
Venu, K., Denisov, V. P., & Halle, B. (1997) · Journal of the American Chemical Society · doi:10.1021/ja963611t · Cited by 108
Kingsley, P. B., Ogg, R. J., Reddick, W. E., & Steen, R. G. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00112-x · Cited by 95
Multiple field strength in vivo T1 and T2 for cerebrospinal fluid protons
Hopkins, A. L., Yeung, H. N., & Bratton, C. B. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030214 · Cited by 84
Naruse, S., Horikawa, Y., Tanaka, C., et al. (1986) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(86)91039-8 · Cited by 65
Spin‐lattice relaxation (T1) times of cerebral white matter in multiple sclerosis
Lacomis, D., Osbakken, M. D., & Gross, G. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030203 · Cited by 55
More than meets the eye: significant regional heterogeneity in human cortical T1☆
Steen, R. G., Reddick, W. E., & Ogg, R. J. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00123-5 · Cited by 54
Mason, G. F., Chu, W., & Hetherington, H. P. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1143 · Cited by 28
Using Flow Relaxography to Elucidate Flow Relaxivity
Lee, J. H., Li, X., Sammi, M. K., & SPRINGER, C. S. J. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1629 · Cited by 25
Self-citationIntimate combination of low- and high-resolution image data: I. real-space PET and1H2O MRI, PETAMRI
Sammi, M. K., Felder, C. A., Fowler, J. S., Lee, J. H., Levy, A. V., Li, X., Logan, J., P�lyka, I., Rooney, W. D., Volkow, N. D., et al. (1999) · Magnetic Resonance in Medicine · Cited by 15
Self-citationKoenig, S. H., & Brown, R. D. (2007) · Encyclopedia of Magnetic Resonance · doi:10.1002/9780470034590.emrstm0466 · Cited by 9
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Myelin and iron concentration in the human brain: a quantitative study of MRI contrast
Stüber, C., Morawski, M., Schäfer, A., Labadie, C., Wähnert, M., Leuze, C., Streicher, M., Barapatre, N., Reimann, K., Geyer, S., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.026 · Cited by 635
Metadata
- Authors
- Rooney, W. D., Johnson, G., Li, X., Cohen, E. R., Kim, S., Ugurbil, K., & Springer, C. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-01-26
- Volume
- 57
- Issue
- 2
- Pages
- 308-318
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2113316687
- Cited by
- 652
- References
- 31
- FWCI
- 13.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.