The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo
Open accessAbstract
Brain water proton (1 H 2 O) longitudinal relaxation time constants (T1) were obtained from three healthy individuals at magnetic field strengths (B0) of 0.2 Tesla (T), 1.0T, 1.5T, 4.0T, and 7.0T. A 5‐mm midventricular axial slice was sampled using a modified Look‐Locker technique with 1.5 mm in‐plane resolution, and 32 time points post‐adiabatic inversion. The results confirmed that for most brain tissues, T1 values increased by more than a factor of 3 between 0.2T and 7T, and over this range were well fitted by T1 (s) = 0.583(B0)0.382, T1(s) = 0.857(B0)0.376, and T1(s) = 1.35(B0)0.340 for white matter (WM), internal GM, and blood 1 H 2 O, respectively. The ventricular cerebrospinal fluid (CSF) 1 H 2 O T1 value did not change with B0, and its average value (standard deviation (SD)) across subjects and magnetic fields was 4.3 (±0.2) s. The tissue 1/T1 values at each field were well correlated with the macromolecular mass fraction, and to a lesser extent tissue iron content. The field‐dependent increases in 1 H 2 O T1 values more than offset the well‐known decrease in typical MRI contrast reagent (CR) relaxivity, and simulations predict that this leads to lower CR concentration detection thresholds with increased magnetic field. Magn Reson Med 57:308–318, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
The effect of age on the non-haemin iron in the human brain
Hallgren, B., & Sourander, P. (1958) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1958.tb12607.x · Cited by 1,427
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citationLanthanide( III ) chelates for NMR biomedical applications
Aime, S., Botta, M., Fasano, M., & Terreno, E. (1998) · Chemical Society Reviews · doi:10.1039/a827019z · Cited by 710
Silver, M. S., Joseph, R. I., & Hoult, D. I. (1985) · Physical Review A · doi:10.1103/physreva.31.2753 · Cited by 400
In vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394
Self-citationImaging at high magnetic fields: initial experiences at 4 T.
Uǧurbil, K., Garwood, M., Ellermann, J., Hendrich, K. S., Hinke, R. M., Hu, X. P., Kim, S. G., Menon, R. S., Merkle, H., & Ogawa, S. (1993) · PubMed · Cited by 282
Self-citationGelman, N., Ewing, J. R., Gorell, J. M., Spickler, E. M., & Solomon, E. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200101)45:1<71::aid-mrm1011>3.0.co;2-2 · Cited by 268
Fischer, H. W., Rinck, P. A., van Haverbeke, Y., & Muller, R. N. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160212 · Cited by 176
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Myelin and iron concentration in the human brain: a quantitative study of MRI contrast
Stüber, C., Morawski, M., Schäfer, A., Labadie, C., Wähnert, M., Leuze, C., Streicher, M., Barapatre, N., Reimann, K., Geyer, S., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.026 · Cited by 635
Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation
Weiskopf, N., Suckling, J., Williams, G., Correia, M. M., Inkster, B., Tait, R., Ooi, C., Bullmore, E. T., & Lutti, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00095 · Cited by 538
Caravan, P., Farrar, C. T., Frullano, L., & Uppal, R. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.267 · Cited by 513
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
Self-citationLifespan maturation and degeneration of human brain white matter
Yeatman, J. D., Wandell, B. A., & Mezer, A. A. (2014) · Nature Communications · doi:10.1038/ncomms5932 · Cited by 432
Low‐field MRI: An MR physics perspective
Marques, J. P., Simonis, F. F. J., & Webb, A. G. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26637 · Cited by 386
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
Near, J., Harris, A. D., Juchem, C., Kreis, R., Marjańska, M., Öz, G., Slotboom, J., Wilson, M., & Gasparovic, C. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4257 · Cited by 342
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
Mapping of brain metabolite distributions by volumetric proton MR spectroscopic imaging (MRSI)
Maudsley, A. A., Domenig, C., Govind, V., Darkazanli, A., Studholme, C., Arheart, K., & Bloomer, C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21875 · Cited by 283
Mezer, A., Yeatman, J. D., Stikov, N., Kay, K. N., Cho, N.-J., Dougherty, R. F., Perry, M. L., Parvizi, J., Hua, L. H., Butts-Pauly, K., et al. (2013) · Nature Medicine · doi:10.1038/nm.3390 · Cited by 282
Clinical applications of 7T MRI in the brain
van der Kolk, A. G., Hendrikse, J., Zwanenburg, J. J. M., Visser, F., & Luijten, P. R. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.07.007 · Cited by 268
Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
Wright, P. J., Mougin, O. E., Totman, J. J., Peters, A. M., Brookes, M. J., Coxon, R., Morris, P. E., Clemence, M., Francis, S. T., Bowtell, R. W., et al. (2008) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-008-0104-8 · Cited by 263
The vertical occipital fasciculus: A century of controversy resolved by in vivo measurements
Yeatman, J. D., Weiner, K. S., Pestilli, F., Rokem, A., Mezer, A., & Wandell, B. A. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1418503111 · Cited by 258
Responsive MRI Agents for Sensing Metabolism in Vivo
De Leon-Rodriguez, L. M., Lubag, A. J. M., Malloy, C. R., Martinez, G. V., Gillies, R. J., & Sherry, A. D. (2009) · Accounts of Chemical Research · doi:10.1021/ar800237f · Cited by 256
Iron, myelin, and the brain: neuroimaging meets neurobiology
Möller, H. E., Bossoni, L., Connor, J. R., Crichton, R. R., Does, M. D., Ward, R. J., Zecca, L., Zucca, F. A., & Ronen, I. (2019) · Trends in Neurosciences · doi:10.1016/j.tins.2019.03.009 · Cited by 207
An interactive meta-analysis of MRI biomarkers of myelin
Mancini, M., Karakuzu, A., Cohen-Adad, J., Cercignani, M., Nichols, T. E., & Stikov, N. (2020) · eLife · doi:10.7554/elife.61523 · Cited by 168
Advanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Autonomic arousals contribute to brain fluid pulsations during sleep
Picchioni, D., Özbay, P. S., Mandelkow, H., de Zwart, J. A., Wang, Y., van Gelderen, P., & Duyn, J. H. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118888 · Cited by 104
Metacognitive ability correlates with hippocampal and prefrontal microstructure
Allen, M., Glen, J. C., Müllensiefen, D., Schwarzkopf, D. S., Fardo, F., Frank, D., Callaghan, M. F., & Rees, G. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.008 · Cited by 85
MRI of whole rat brain perivascular network reveals role for ventricles in brain waste clearance
Magdoom, K. N., Brown, A., Rey, J., Mareci, T. H., King, M. A., & Sarntinoranont, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-44938-1 · Cited by 35
Metadata
- Authors
- Rooney, W. D., Johnson, G., Li, X., Cohen, E. R., Kim, S., Ugurbil, K., & Springer, C. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-01-26
- Volume
- 57
- Issue
- 2
- Pages
- 308-318
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2113316687
- Cited by
- 652
- References
- 31
- FWCI
- 13.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.