The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Myocardial T1 mapping: Application to patients with acute and chronic myocardial infarction
Open accessAbstract
T1 maps obtained with modified Look‐Locker inversion recovery (MOLLI) can be used to measure myocardial T1. We aimed to evaluate the potential of MOLLI T1 mapping for the assessment of acute and chronic myocardial infarction (MI). A total of 24 patients with a first MI underwent MRI within 8 days and after 6 months. T1 mapping was performed at baseline and at selected intervals between 2–20 min following administration of gadopentetate dimeglumine (Gd‐DTPA). Delayed‐enhancement (DE) imaging served as the reference standard for delineation of the infarct zone. On T1 maps the myocardial T1 relaxation time was assessed in hyperenhanced areas, hypoenhanced infarct cores, and remote myocardium. The planimetric size of myocardial areas with standardized T1 threshold values was measured. Acute and chronic MI exhibited different T1 changes. Precontrast threshold T1 maps detected segmental abnormalities caused by acute MI with 96% sensitivity and 91% specificity. Agreement between measurements of infarct size from T1 mapping and DE imaging was higher in chronic than in acute infarcts. Precontrast T1 maps enable the detection of acute MI. Acute and chronic MI show different patterns of T1 changes. Standardized T1 thresholds provide the potential to dichotomously identify areas of infarction. Magn Reson Med 58:34–40, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999) · Circulation · doi:10.1161/01.cir.100.19.1992 · Cited by 2,581
An Improved MR Imaging Technique for the Visualization of Myocardial Infarction
Simonetti, O. P., Kim, R. J., Fieno, D. S., Hillenbrand, H. B., Wu, E., Bundy, J. M., Finn, J. P., & Judd, R. M. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja50215 · Cited by 1,358
Wu, K. C., Zerhouni, E. A., Judd, R. M., Lugo-Olivieri, C. H., Barouch, L. A., Schulman, S. P., Blumenthal, R. S., & Lima, J. A. C. (1998) · Circulation · doi:10.1161/01.cir.97.8.765 · Cited by 1,357
Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
Messroghli, D. R., Radjenovic, A., Kozerke, S., Higgins, D. M., Sivananthan, M. U., & Ridgway, J. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20110 · Cited by 1,349
Self-citationWagner, A., Mahrholdt, H., Holly, T. A., Elliott, M. D., Regenfus, M., Parker, M., Klocke, F. J., Bonow, R. O., Kim, R. J., & Judd, R. M. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12389-6 · Cited by 1,307
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
Mahrholdt, H., Goedecke, C., Wagner, A., Meinhardt, G., Athanasiadis, A., Vogelsberg, H., Fritz, P., Klingel, K., Kandolf, R., & Sechtem, U. (2004) · Circulation · doi:10.1161/01.cir.0000118493.13323.81 · Cited by 1,030
Cardiovascular Magnetic Resonance in Cardiac Amyloidosis
Maceira, A. M., Joshi, J., Prasad, S. K., Moon, J. C., Perugini, E., Harding, I., Sheppard, M. N., Poole-Wilson, P. A., Hawkins, P. N., & Pennell, D. J. (2005) · Circulation · doi:10.1161/01.cir.0000152819.97857.9d · Cited by 982
Friedrich, M. G., Strohm, O., Schulz-Menger, J., Marciniak, H., Luft, F. C., & Dietz, R. (1998) · Circulation · doi:10.1161/01.cir.97.18.1802 · Cited by 558
Self-citationAbdel-Aty, H., Zagrosek, A., Schulz-Menger, J., Taylor, A. J., Messroghli, D., Kumar, A., Gross, M., Dietz, R., & Friedrich, M. G. (2004) · Circulation · doi:10.1161/01.cir.0000127428.10985.c6 · Cited by 539
Self-citationAmado, L. C., Gerber, B. L., Gupta, S. N., Rettmann, D. W., Szarf, G., Schock, R., Nasir, K., Kraitchman, D. L., & Lima, J. A. C. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.09.020 · Cited by 508
How We Perform Delayed Enhancement Imaging
Kim, R. J., Shah, D. J., & Judd, R. M. (2003) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120022267 · Cited by 345
Messroghli, D. R., Plein, S., Higgins, D. M., Walters, K., Jones, T. R., Ridgway, J. P., & Sivananthan, M. U. (2006) · Radiology · doi:10.1148/radiol.2382041903 · Cited by 239
Self-citationFlacke, S. J., Fischer, S. E., & Lorenz, C. H. (2001) · Radiology · doi:10.1148/radiology.218.3.r01fe18703 · Cited by 211
Messroghli, D., Bainbridge, G. J., Alfakih, K., Jones, T. R., Plein, S., Ridgway, J. P., & Sivananthan, M. U. (2005) · Radiology · doi:10.1148/radiol.2351040249 · Cited by 73
Self-citationAmado, L. C., Kraitchman, D. L., Gerber, B. L., Castillo, E. A., Boston, R. C., Grayzel, J., & Lima, J. A. C. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.034 · Cited by 53
Cited by
Messroghli, D. R., Moon, J. C., Ferreira, V. M., Grosse-Wortmann, L., He, T., Kellman, P., Mascherbauer, J., Nezafat, R., Salerno, M., Schelbert, E. B., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0389-8 · Cited by 1,727
Self-citationAssessment of Myocardial Fibrosis With Cardiovascular Magnetic Resonance
Mewton, N., Liu, C. Y., Croisille, P., Bluemke, D., & Lima, J. A. C. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.11.013 · Cited by 984
T1-mapping in the heart: accuracy and precision
Kellman, P., & Hansen, M. S. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-2 · Cited by 764
Puntmann, V. O., Voigt, T., Chen, Z., Mayr, M., Karim, R., Rhode, K., Pastor, A., Carr-White, G., Razavi, R., Schaeffter, T., et al. (2013) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2012.08.019 · Cited by 487
Human cardiac organoids for the modelling of myocardial infarction and drug cardiotoxicity
Richards, D. J., Li, Y., Kerr, C. M., Yao, J., Beeson, G. C., Coyle, R. C., Chen, X., Jia, J., Damon, B., Wilson, R., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0539-4 · Cited by 439
Metadata
- Authors
- Messroghli, D. R., Walters, K., Plein, S., Sparrow, P., Friedrich, M. G., Ridgway, J. P., & Sivananthan, M. U.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-07
- Volume
- 58
- Issue
- 1
- Pages
- 34-40
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2111896397
- Cited by
- 351
- References
- 16
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.