Gibbs tracking: A novel approach for the reconstruction of neuronal pathways
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Reconstruction of neuronal fibers using diffusion‐weighted (DW) MRI is an emerging method in biomedical research. Existing fiber‐tracking algorithms are commonly based on the “walker principle.” Fibers are reconstructed as trajectories of “walkers,” which are guided according to local diffusion properties. In this study, a new method of fiber tracking is proposed that does not engage any “walking” algorithm. It resolves a number of inherent problems of the “walking” approach, in particular the reconstruction of crossing and spreading fibers. In the proposed method, the fibers are built with small line elements. Each line element contributes an anisotropic term to the simulated DW signal, which is adjusted to the measured signal. This method demonstrates good results for simulated fibers. A single in vivo result demonstrates the successful reconstruction of the dominant neuronal pathways. A comparison with the diffusion tensor imaging (DTI)‐based fiber assignment with continuous tracking (FACT) method and the probabilistic index of connectivity (PICo) method based on a multitensor model is performed for the callosal fibers. The result shows a strong increase in the number of reconstructed fibers. These almost fill the total white matter (WM) volume and connect a large area of the cortex. The method is very computationally expensive. Possible ways to address this problem are discussed. Magn Reson Med 60:953–963, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monte Carlo sampling methods using Markov chains and their applications.
Hastings, W. K. (1970) · Biometrika · doi:10.1093/biomet/57.1.97 · Cited by 15,195
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547 · cited 4×
“The background of the phantom was characterized by an isotropic diffusivity of 3.19 m2/ms, which is typical for cerebrospinal fluid (CSF) (29).”
BackgroundInfluentialCharacterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 1×
“In contrast, other approaches (3,9,10) use the MDT model to solve the inverse problem (that is, to find the fiber orientation given the signal).”
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Diffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Parker, G. J. M., Haroon, H. A., & Wheeler‐Kingshott, C. A. M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10350 · Cited by 527 · cited 1×
“A further comparison was performed among the FACT, PICo (16,17,36), and Gibbs tracking methods.”
Method
Cited by
Smith, R. E., Tournier, J.-D., Calamante, F., & Connelly, A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.005 · Cited by 1,216
“…not streamlines-based, such as front evolution (e.g. Jackowski et al., 2005; Parker et al., 2002, Tournier et al., 2003), geodesics (e.g. Jbabdi et al., 2008; Sepasian et al., 2012) and so-called ‘global’ tractography approaches (e.g. Jbabdi et al., 2007; Kreher et al., 2008; Reisert et al., 2011).”
BackgroundDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
SIFT: Spherical-deconvolution informed filtering of tractograms
Smith, R. E., Tournier, J.-D., Calamante, F., & Connelly, A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.049 · Cited by 752
Lead-DBS v2: Towards a comprehensive pipeline for deep brain stimulation imaging
Horn, A., Li, N., Dembek, T. A., Kappel, A., Boulay, C., Ewert, S., Tietze, A., Husch, A., Perera, T., Neumann, W.-J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.068 · Cited by 739
Tractography: Where Do We Go from Here?
Jbabdi, S., & Johansen-Berg, H. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0033 · Cited by 614
“This is in the spirit of global approaches to tractography (Aganj et al., 2011; Jbabdi et al., 2007, 2008; Kreher et al., 2008; Parker et al., 2002; Reisert et al., 2011; Sotiropoulos et al., 2010b), in which the estimate of fiber orientation at a given voxel is informed by estimated orientations in…”
Metadata
- Authors
- Kreher, B. W., Mader, I., & Kiselev, V. G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-09-24
- Volume
- 60
- Issue
- 4
- Pages
- 953-963
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1964714863
- Cited by
- 157
- References
- 9
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.