The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Open accessAbstract
A new approach to autocalibrating, coil‐by‐coil parallel imaging reconstruction, is presented. It is a generalized reconstruction framework based on self‐consistency. The reconstruction problem is formulated as an optimization that yields the most consistent solution with the calibration and acquisition data. The approach is general and can accurately reconstruct images from arbitrary k‐space sampling patterns. The formulation can flexibly incorporate additional image priors such as off‐resonance correction and regularization terms that appear in compressed sensing. Several iterative strategies to solve the posed reconstruction problem in both image and k‐space domain are presented. These are based on a projection over convex sets and conjugate gradient algorithms. Phantom and in vivo studies demonstrate efficient reconstructions from undersampled Cartesian and spiral trajectories. Reconstructions that include off‐resonance correction and nonlinear ℓ 1‐wavelet regularization are also demonstrated. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
LSQR: An Algorithm for Sparse Linear Equations and Sparse Least Squares
Paige, C. C., & Saunders, M. A. (1982) · ACM Transactions on Mathematical Software · doi:10.1145/355984.355989 · Cited by 4,387
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Nonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
(1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7 · Cited by 569
Cited by
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392
Self-citationNonlocal Transform-Domain Filter for Volumetric Data Denoising and Reconstruction
Maggioni, M., Katkovnik, V., Egiazarian, K., & Foi, A. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2012.2210725 · Cited by 1,002
Accelerating magnetic resonance imaging via deep learning
Wang, S., Su, Z., Ying, L., Peng, X., Zhu, S., Liang, F., Feng, D., & Liang, D. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493320 · Cited by 800
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Knoll, F., Hammernik, K., Zhang, C., Moeller, S., Pock, T., Sodickson, D. K., & Akcakaya, M. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2950640 · Cited by 403
Compressed sensing MRI: a review of the clinical literature
Jaspan, O. N., Fleysher, R., & Lipton, M. L. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20150487 · Cited by 393
Akçakaya, M., Moeller, S., Weingärtner, S., & Uğurbil, K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27420 · Cited by 391
Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391
Self-citationRadiotherapy planning using MRI
Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357
Qu, X., Hou, Y., Lam, F., Guo, D., Zhong, J., & Chen, Z. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.09.007 · Cited by 340
Deep Residual Learning for Accelerated MRI Using Magnitude and Phase Networks
Lee, D., Yoo, J., Tak, S., & Ye, J. C. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2821699 · Cited by 340
Yaman, B., Hosseini, S. A. H., Moeller, S., Ellermann, J., Uğurbil, K., & Akçakaya, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28378 · Cited by 327
Haldar, J. P. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2293974 · Cited by 326
Murphy, M., Alley, M., Demmel, J., Keutzer, K., Vasanawala, S., & Lustig, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2188039 · Cited by 313
Self-citationCompressed sensing for body MRI
Feng, L., Benkert, T., Block, K. T., Sodickson, D. K., Otazo, R., & Chandarana, H. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25547 · Cited by 306
Sarracanie, M., LaPierre, C. D., Salameh, N., Waddington, D. E. J., Witzel, T., & Rosen, M. S. (2015) · Scientific Reports · doi:10.1038/srep15177 · Cited by 295
Coil compression for accelerated imaging with Cartesian sampling
Zhang, T., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24267 · Cited by 273
Self-citation
Metadata
- Authors
- Lustig, M., & Pauly, J. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-06
- Volume
- 64
- Issue
- 2
- Pages
- 457-471
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2047544187
- Cited by
- 822
- References
- 20
- FWCI
- 27.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.