The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Combination of compressed sensing and parallel imaging for highly accelerated first‐pass cardiac perfusion MRI
Open accessAbstract
First‐pass cardiac perfusion MRI is a natural candidate for compressed sensing acceleration since its representation in the combined temporal Fourier and spatial domain is sparse and the required incoherence can be effectively accomplished by k‐t random undersampling. However, the required number of samples in practice (three to five times the number of sparse coefficients) limits the acceleration for compressed sensing alone. Parallel imaging may also be used to accelerate cardiac perfusion MRI, with acceleration factors ultimately limited by noise amplification. In this work, compressed sensing and parallel imaging are combined by merging the k‐t SPARSE technique with sensitivity encoding (SENSE) reconstruction to substantially increase the acceleration rate for perfusion imaging. We also present a new theoretical framework for understanding the combination of k‐t SPARSE with SENSE based on distributed compressed sensing theory. This framework, which identifies parallel imaging as a distributed multisensor implementation of compressed sensing, enables an estimate of feasible acceleration for the combined approach. We demonstrate feasibility of 8‐fold acceleration in vivo with whole‐heart coverage and high spatial and temporal resolution using standard coil arrays. The method is relatively insensitive to respiratory motion artifacts and presents similar temporal fidelity and image quality when compared to Generalized autocalibrating partially parallel acquisitions (GRAPPA) with 2‐fold acceleration. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Self-citationAdvances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Extensions of compressed sensing
Tsaig, Y., & Donoho, D. L. (2006) · Signal Processing · doi:10.1016/j.sigpro.2005.05.029 · Cited by 947
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Jung, H., Sung, K., Nayak, K. S., Kim, E. Y., & Ye, J. C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21757 · Cited by 669
Compressed sensing in dynamic MRI
Gamper, U., Boesiger, P., & Kozerke, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21477 · Cited by 569
Cited by
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
Self-citationAI in Medical Imaging Informatics: Current Challenges and Future Directions
Panayides, A. S., Amini, A., Filipovic, N. D., Sharma, A., Tsaftaris, S. A., Young, A., Foran, D., Do, N., Golemati, S., Kurc, T., et al. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2991043 · Cited by 713
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Self-citationFeng, L., Axel, L., Chandarana, H., Block, K. T., Sodickson, D. K., & Otazo, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25665 · Cited by 667
Self-citationEo, T., Jun, Y., Kim, T., Jang, J., Lee, H., & Hwang, D. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27201 · Cited by 455
Qu, X., Hou, Y., Lam, F., Guo, D., Zhong, J., & Chen, Z. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.09.007 · Cited by 340
Yaman, B., Hosseini, S. A. H., Moeller, S., Ellermann, J., Uğurbil, K., & Akçakaya, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28378 · Cited by 327
Murphy, M., Alley, M., Demmel, J., Keutzer, K., Vasanawala, S., & Lustig, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2188039 · Cited by 313
Compressed sensing for body MRI
Feng, L., Benkert, T., Block, K. T., Sodickson, D. K., Otazo, R., & Chandarana, H. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25547 · Cited by 306
Self-citationSarracanie, M., LaPierre, C. D., Salameh, N., Waddington, D. E. J., Witzel, T., & Rosen, M. S. (2015) · Scientific Reports · doi:10.1038/srep15177 · Cited by 295
Machine learning in cardiovascular magnetic resonance: basic concepts and applications
Leiner, T., Rueckert, D., Suinesiaputra, A., Baeßler, B., Nezafat, R., Išgum, I., & Young, A. A. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0575-y · Cited by 282
Coil compression for accelerated imaging with Cartesian sampling
Zhang, T., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24267 · Cited by 273
Fast Multidimensional NMR Spectroscopy Using Compressed Sensing
Holland, D. J., Bostock, M. J., Gladden, L. F., & Nietlispach, D. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201100440 · Cited by 272
On the Applications of Robust PCA in Image and Video Processing
Bouwmans, T., Javed, S., Zhang, H., Lin, Z., & Otazo, R. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2853589 · Cited by 255
Self-citationFast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
A Regularized MRI Image Reconstruction based on Hessian Penalty Term on CPU/GPU Systems
Piccialli, F., Cuomo, S., & De Michele, P. (2013) · Procedia Computer Science · doi:10.1016/j.procs.2013.06.001 · Cited by 45
Metadata
- Authors
- Otazo, R., Kim, D., Axel, L., & Sodickson, D. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-08-25
- Volume
- 64
- Issue
- 3
- Pages
- 767-776
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1979954835
- Cited by
- 571
- References
- 16
- FWCI
- 23.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.