The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Estimation of tensors and tensor‐derived measures in diffusional kurtosis imaging
Open accessAbstract
This article presents two related advancements to the diffusional kurtosis imaging estimation framework to increase its robustness to noise, motion, and imaging artifacts. The first advancement substantially improves the estimation of diffusion and kurtosis tensors parameterizing the diffusional kurtosis imaging model. Rather than utilizing conventional unconstrained least squares methods, the tensor estimation problem is formulated as linearly constrained linear least squares, where the constraints ensure physically and/or biologically plausible tensor estimates. The exact solution to the constrained problem is found via convex quadratic programming methods or, alternatively, an approximate solution is determined through a fast heuristic algorithm. The computationally more demanding quadratic programming‐based method is more flexible, allowing for an arbitrary number of diffusion weightings and different gradient sets for each diffusion weighting. The heuristic algorithm is suitable for real‐time settings such as on clinical scanners, where run time is crucial. The advantage offered by the proposed constrained algorithms is demonstrated using in vivo human brain images. The proposed constrained methods allow for shorter scan times and/or higher spatial resolution for a given fidelity of the diffusional kurtosis imaging parametric maps. The second advancement increases the efficiency and accuracy of the estimation of mean and radial kurtoses by applying exact closed‐form formulae. Magn Reson Med, 2011. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(1999) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/b98874 · Cited by 9,482
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Dysmyelination revealed through MRI as increased radial (but unchanged axial) diffusion of water
Song, S.-K., Sun, S.-W., Ramsbottom, M. J., Chang, C., Russell, J., & Cross, A. H. (2002) · NeuroImage · doi:10.1006/nimg.2002.1267 · Cited by 2,582
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488
Self-citationBasser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
MRI quantification of non-gaussian water diffusion by kurtosis analysis
Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1518 · Cited by 1,251
Self-citation
Cited by
White matter characterization with diffusional kurtosis imaging
Fieremans, E., Jensen, J. H., & Helpern, J. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.006 · Cited by 561
Self-citationSteven, A. J., Zhuo, J., & Melhem, E. R. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11365 · Cited by 397
Quantitative assessment of diffusional kurtosis anisotropy
Glenn, G. R., Helpern, J. A., Tabesh, A., & Jensen, J. H. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3271 · Cited by 113
Self-citationKamagata, K., Zalesky, A., Hatano, T., Ueda, R., Di Biase, M. A., Okuzumi, A., Shimoji, K., Hori, M., Caeyenberghs, K., Pantelis, C., et al. (2017) · Human Brain Mapping · doi:10.1002/hbm.23628 · Cited by 106
Falangola, M. F., Guilfoyle, D. N., Tabesh, A., Hui, E. S., Nie, X., Jensen, J. H., Gerum, S. V., Hu, C., LaFrancois, J., Collins, H. R., et al. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3140 · Cited by 96
Self-citationDiffusional kurtosis imaging of the developing brain
Paydar, A., Fieremans, E., Nwankwo, J. I., Lazar, M., Sheth, H. D., Adisetiyo, V., Helpern, J. A., Jensen, J. H., & Milla, S. S. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3764 · Cited by 91
Self-citationAging in deep gray matter and white matter revealed by diffusional kurtosis imaging
Gong, N.-J., Wong, C.-S., Chan, C.-C., Leung, L.-M., & Chu, Y.-C. (2014) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2014.03.011 · Cited by 82
Ligneul, C., Palombo, M., Hernández-Garzón, E., Carrillo-de Sauvage, M.-A., Flament, J., Hantraye, P., Brouillet, E., Bonvento, G., Escartin, C., & Valette, J. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.02.046 · Cited by 77
Hutchinson, E. B., Avram, A. V., Irfanoglu, M. O., Koay, C. G., Barnett, A. S., Komlosh, M. E., Özarslan, E., Schwerin, S. C., Juliano, S. L., & Pierpaoli, C. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26575 · Cited by 73
Glenn, G. R., Kuo, L. W., Chao, Y. P., Lee, C. Y., Helpern, J. A., & Jensen, J. H. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4714 · Cited by 58
Self-citationWhite matter biomarkers from fast protocols using axially symmetric diffusion kurtosis imaging
Hansen, B., Khan, A. R., Shemesh, N., Lund, T. E., Sangill, R., Eskildsen, S. F., Østergaard, L., & Jespersen, S. N. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3741 · Cited by 46
Cognitive Impairment, Neuroimaging, and Alzheimer Neuropathology in Mouse Models of Down Syndrome
D. Hamlett, E., A. Boger, H., Ledreux, A., M. Kelley, C., J. Mufson, E., F. Falangola, M., N. Guilfoyle, D., A. Nixon, R., Patterson, D., Duval, N., et al. (2015) · Current Alzheimer Research · doi:10.2174/1567205012666150921095505 · Cited by 46
Gatto, R. G., Ye, A. Q., Colon-Perez, L., Mareci, T. H., Lysakowski, A., Price, S. D., Brady, S. T., Karaman, M., Morfini, G., & Magin, R. L. (2019) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-019-00742-6 · Cited by 42
Gatto, R. G., Amin, M., Finkielsztein, A., Weissmann, C., Barrett, T., Lamoutte, C., Uchitel, O., Sumagin, R., Mareci, T. H., & Magin, R. L. (2019) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.1080/21678421.2019.1620285 · Cited by 31
Falangola, M. F., Nie, X., Ward, R., Dhiman, S., Voltin, J., Nietert, P. J., & Jensen, J. H. (2021) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2021.06.022 · Cited by 25
Felisatti, F., Gonneaud, J., Palix, C., Garnier-Crussard, A., Mézenge, F., Landeau, B., Chocat, A., Quillard, A., Ferrand-Devouge, E., de La Sayette, V., et al. (2022) · Neurology · doi:10.1212/wnl.0000000000200270 · Cited by 26
Diffusion MRI detects early brain microstructure abnormalities in 2-month-old 3×Tg-AD mice
Falangola, M. F., Nie, X., Ward, R., McKinnon, E. T., Dhiman, S., Nietert, P. J., Helpern, J. A., & Jensen, J. H. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4346 · Cited by 22
Self-citationNie, X., Falangola, M. F., Ward, R., McKinnon, E. T., Helpern, J. A., Nietert, P. J., & Jensen, J. H. (2019) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2018.12.003 · Cited by 22
Self-citationCrombé, A., Nicolas, R., Richard, N., Tourdias, T., & Hiba, B. (2022) · Scientific Reports · doi:10.1038/s41598-022-15511-0 · Cited by 13
Falangola, M. F., Nie, X., Voltin, J., Ward, R., Dhiman, S., Nietert, P. J., & Jensen, J. H. (2022) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2022.09.002 · Cited by 6
Self-citation
Metadata
- Authors
- Tabesh, A., Jensen, J. H., Ardekani, B. A., & Helpern, J. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-10-28
- Volume
- 65
- Issue
- 3
- Pages
- 823-836
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2155162743
- Cited by
- 460
- References
- 26
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.