CoChat

Relationship between the diffusion time and the diffusion MRI signal observed at 17.2 tesla in the healthy rat brain cortex

Open access
Pyatigorskaya, Nadya, Le Bihan, Denis, Reynaud, Olivier, Ciobanu, Luisa · 2014 · Magnetic Resonance in Medicine
Cited by 80

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Purpose: To investigate the diffusion time dependency of water diffusion in cortical brain tissue. Methods: We have combined an oscillating gradient spin‐echo (OGSE) and a pulse gradient spin echo (PGSE) spin‐echo sequence to acquire diffusion‐weighted MRI images in vivo in healthy rat brains over a wide range of diffusion times (1.9–29.2 ms) and estimated the parameters of the biexponential and cumulant expansion diffusion MRI signal models. Diffusion images were obtained at 17.2 Tesla with maximum gradient strength of 1000 mT/m allowing 40 b values up to approximately 4000 s/mm 2. Results: At all diffusion times the log plot of diffusion signal attenuation versus b value was curved, confirming that diffusion is not free, even at very short diffusion times. This suggests that the length scale of obstacles to diffusion must be smaller than the corresponding shortest observed diffusion distance (approximately 1.7 μm). The diffusion MRI signal was also not found in a steady‐state, even at our longest diffusion time (29.2 ms), suggesting some degree of segregation of water in pools. Conclusion: Overall, the results showed that the parameters derived from the two diffusion models could not well be related to specific tissue features. More specific models must be developed taking into account diffusion signal behavior at high b values and short diffusion times. Magn Reson Med 72:492–500, 2014. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24921

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 80

Metadata

Authors
Pyatigorskaya, N., Le Bihan, D., Reynaud, O., & Ciobanu, L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2013-09-10
Volume
72
Issue
2
Pages
492-500
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1749546866
Cited by
80
References
10
FWCI
4.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relationship between the diffusion time and the diffusion MRI signal observed at 17.2 tesla in the healthy rat brain cortex. https://app.cochat.ai/papers/10.1002/mrm.24921
The paper
Pyatigorskaya, N., Le Bihan, D., Reynaud, O., & Ciobanu, L. (2014). Relationship between the diffusion time and the diffusion MRI signal observed at 17.2 tesla in the healthy rat brain cortex. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24921

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.