Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 718

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRI

Open access
Feng, Li, Grimm, Robert, Block, Kai Tobias, Chandarana, Hersh, Kim, Sungheon, Xu, Jian, Axel, Leon, Sodickson, Daniel K., Otazo, Ricardo·2014·Magnetic Resonance in Medicine

Abstract

Purpose: To develop a fast and flexible free‐breathing dynamic volumetric MRI technique, iterative Golden‐angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden‐angle radial sampling. Methods: Radial k‐space data are acquired continuously using the golden‐angle scheme and sorted into time series by grouping an arbitrary number of consecutive spokes into temporal frames. An iterative reconstruction procedure is then performed on the undersampled time series where joint multicoil sparsity is enforced by applying a total‐variation constraint along the temporal dimension. Required coil‐sensitivity profiles are obtained from the time‐averaged data. Results: iGRASP achieved higher acceleration capability than either parallel imaging or coil‐by‐coil compressed sensing alone. It enabled dynamic volumetric imaging with high spatial and temporal resolution for various clinical applications, including free‐breathing dynamic contrast‐enhanced imaging in the abdomen of both adult and pediatric patients, and in the breast and neck of adult patients. Conclusion: The high performance and flexibility provided by iGRASP can improve clinical studies that require robustness to motion and simultaneous high spatial and temporal resolution. Magn Reson Med 72:707–717, 2014. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24980

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 718

Metadata

Authors
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2013-10-18
Volume
72
Issue
3
Pages
707-717
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1482297123
Cited by
718
References
30
FWCI
23.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.