The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRI
Open accessAbstract
Purpose: To develop a fast and flexible free‐breathing dynamic volumetric MRI technique, iterative Golden‐angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden‐angle radial sampling. Methods: Radial k‐space data are acquired continuously using the golden‐angle scheme and sorted into time series by grouping an arbitrary number of consecutive spokes into temporal frames. An iterative reconstruction procedure is then performed on the undersampled time series where joint multicoil sparsity is enforced by applying a total‐variation constraint along the temporal dimension. Required coil‐sensitivity profiles are obtained from the time‐averaged data. Results: iGRASP achieved higher acceleration capability than either parallel imaging or coil‐by‐coil compressed sensing alone. It enabled dynamic volumetric imaging with high spatial and temporal resolution for various clinical applications, including free‐breathing dynamic contrast‐enhanced imaging in the abdomen of both adult and pediatric patients, and in the breast and neck of adult patients. Conclusion: The high performance and flexibility provided by iGRASP can improve clinical studies that require robustness to motion and simultaneous high spatial and temporal resolution. Magn Reson Med 72:707–717, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
OpenMP: an industry standard API for shared-memory programming
Dagum, L., & Menon, R. (1998) · IEEE Computational Science and Engineering · doi:10.1109/99.660313 · Cited by 3,343
Updating quasi-Newton matrices with limited storage
Nocedal, J. (1980) · Mathematics of Computation · doi:10.1090/s0025-5718-1980-0572855-7 · Cited by 2,958
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Self-citationBlock, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824
Self-citationk‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Jung, H., Sung, K., Nayak, K. S., Kim, E. Y., & Ye, J. C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21757 · Cited by 669
“Keyhole” method for accelerating imaging of contrast agent uptake
Van Vaals, J. J., Brummer, M. E., Thomas Dixon, W., Tuithof, H. H., Engels, H., Nelson, R. C., Gerety, B. M., Chezmar, J. L., & Den Boer, J. A. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030419 · Cited by 602
Otazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571
Self-citationCompressed sensing in dynamic MRI
Gamper, U., Boesiger, P., & Kozerke, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21477 · Cited by 569
Projection Reconstruction Techniques for Reduction of Motion Effects in MRI
Glover, G. H., & Pauly, J. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280209 · Cited by 563
Dynamic contrast‐enhanced MRI in clinical oncology: Current status and future directions
Padhani, A. R. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10176 · Cited by 472
k-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity
Lustig, M. S., Santos, J. M., Donoho, D. L., & Pauly, J. M. (2006) · Cited by 313
Chandarana, H., Block, K. T., Rosenkrantz, A. B., Lim, R., Kim, D. C., Mossa, D. J., Babb, J. S., Kiefer, B., & Lee, V. S. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e31821eea45 · Cited by 299
Self-citationArray compression for MRI with large coil arrays
Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21237 · Cited by 257
Chandarana, H., Feng, L., Block, T. K., Rosenkrantz, A. B., Lim, R. P., Babb, J. S., Sodickson, D. K., & Otazo, R. (2013) · Investigative Radiology · doi:10.1097/rli.0b013e318271869c · Cited by 248
Self-citationHighly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE
Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24440 · Cited by 232
Self-citationMRI temporal acceleration techniques
Tsao, J., & Kozerke, S. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23640 · Cited by 195
Motion corrected compressed sensing for free‐breathing dynamic cardiac MRI
Usman, M., Atkinson, D., Odille, F., Kolbitsch, C., Vaillant, G., Schaeffter, T., Batchelor, P. G., & Prieto, C. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24463 · Cited by 185
Accelerated phase‐contrast cine MRI using k‐t SPARSE‐SENSE
Kim, D. C., Dyvorne, H., Otazo, R., Feng, L., Sodickson, D. K., & Lee, V. S. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23088 · Cited by 117
Self-citationThe influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI
Chan, R. W., Ramsay, E. A., Cheung, E., & Plewes, D. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23008 · Cited by 108
Feng, L., Otazo, R., Jung, H., Jensen, J. H., Ye, J. C., Sodickson, D. K., & Kim, D. C. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22756 · Cited by 84
Self-citationPrieto, C., Uribe, S. A., Razavi, R., Atkinson, D., & Schaeffter, T. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22446 · Cited by 56
Xu, B., Spincemaille, P., Chen, G., Agrawal, M., Nguyen, T. D., Prince, M. R., & Wang, Y. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24253 · Cited by 46
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
Feng, L., Axel, L., Chandarana, H., Block, K. T., Sodickson, D. K., & Otazo, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25665 · Cited by 667
Self-citationMaspero, M., Savenije, M. H. F., Dinkla, A. M., Seevinck, P. R., Intven, M. P. W., Jurgenliemk-Schulz, I. M., Kerkmeijer, L. G. W., & van den Berg, C. A. T. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aada6d · Cited by 253
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Automated reference-free detection of motion artifacts in magnetic resonance images
Küstner, T., Liebgott, A., Mauch, L., Martirosian, P., Bamberg, F., Nikolaou, K., Yang, B., Schick, F., & Gatidis, S. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-017-0650-z · Cited by 102
Metadata
- Authors
- Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-10-18
- Volume
- 72
- Issue
- 3
- Pages
- 707-717
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1482297123
- Cited by
- 718
- References
- 30
- FWCI
- 23.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.