Conduction studies in peripheral cat nerve using implanted electrodes: I. Methods and findings in controls
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Silicone rubber cuff and patch electrodes with multiple contacts were implanted along the sciatic‐tibial‐plantar nerves in cat for repeated studies of conduction properties of normal peripheral nerve over periods of time. The contacts were used in various combinations for precise localization of changes in conduction velocities and excitability along the extent of normal nerves. In this paper the particular characteristics and limitations associated with cuff‐electrode recordings of neural activity are discussed. The nerve action potential was recorded using a tripolar configuration with a central lead flanked by two shunted leads at symmetrical distances. This configuration records the spatial derivative of the action potential and rejects potentials from sources outside the cuff. The voltage changes are restricted by the silicone cuff, and the dynamic range is therefore very high, allowing detection from single myelinated fibers to whole nerve responses. The electrodes are well suited for following the development of regeneration and degeneration following experimental lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313
Cited by
Outcome measures of peripheral nerve regeneration
Wood, M. D., Kemp, S. W. P., Weber, C., Borschel, G. H., & Gordon, T. (2011) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2011.04.008 · Cited by 264
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Self-citationPolyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff
Schuettler, M., Donaldson, N., Seetohul, V., & Taylor, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036016 · Cited by 50
Polymeric C-shaped cuff electrode for recording of peripheral nerve signal
Xue, N., Sun, T., Tsang, W. M., Delgado-Martinez, I., Lee, S.-H., Sheshadri, S., Xiang, Z., Merugu, S., Gu, Y., Yen, S.-C., et al. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.006 · Cited by 48
Krarup, C., Loeb, G. E., & Pezeshkpour, G. H. (1989) · Muscle & Nerve · doi:10.1002/mus.880121108 · Cited by 28
Self-citationHow to Use Nerve Cuffs to Stimulate, Record or Modulate Neural Activity
Hoffer, J.-A., & Kallesøe, K. (2000) · Frontiers in Neuroscience · doi:10.1201/9781420039054.ch5 · Cited by 21
The foreign body response and morphometric changes associated with mesh-style peripheral nerve cuffs
Christensen, M. B., & Tresco, P. A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.059 · Cited by 19
Metadata
- Authors
- Christian, K., & Loeb, G. E.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 1988-09
- Volume
- 11
- Issue
- 9
- Pages
- 922-932
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2171965678
- Cited by
- 46
- References
- 1
- FWCI
- 0.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.