Conduction studies in peripheral cat nerve using implanted electrodes: II. The effects of prolonged constriction on regeneration of crushed nerve fibers
The DOI matches its Crossref record.
Abstract
Arrays of chronically implanted electrodes were used to examine the time course of elongation and maturation of peripheral nerve fibers in the cat after crush of the tibial nerve in the proximal calf. Regeneration after crush alone was compared with crush 5 mm proximal to a tight constriction of the nerve. Regeneration was monitored by the progression of excitability along the electrode arrays on the tibial and plantar nerves. The sensitivity was sufficient to record the averaged activity in single nerve fibers allowing detection of the earliest regeneration. The diameters of the fastest regenerating fibers were estimated from the conduction velocity proximal to the site of crush. Both after crush alone, and after crush constriction, small myelinated fibers regenerated in front of large fibers. The rate of elongation after crush alone was 3.2 mm/day, whereas it was slower (P < 0.02) distal to crush + constriction (2.2 mm/day). In both lesions, the extrapolated delay to onset of regeneration was 8 days. In observations up to 300 days after crush, maturation was delayed or impaired by the constriction, and the compound nerve action potential had a smaller amplitude and a dispersed shape. Transverse sections of nerves after crush + constriction showed a diminished number of large and an increased number of small fibers compared with crush alone, possibly due to persistent branching of regenerated fibers. After both crush alone and crush + constriction, regenerated fibers had similar g ratios, suggesting that myelination developed fully in fibers of diminshed diameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 36
- Berry CM, 1944, The electrical activity of regenerating nerves in the cat, J Neurophysiol, 7, 103, 10.1152/jn.1944.7.2.103 · DOI
- 10.1136/jnnp.42.5.436 · DOI
- 10.1113/jphysiol.1961.sp006724 · DOI · Paper page
- 10.1113/jphysiol.1964.sp007369 · DOI
- 10.1113/jphysiol.1978.sp012588 · DOI · Paper page
- 10.1038/262705a0 · doi:10.1038/262705a0
- 10.1002/ana.410090611 · DOI
- Erlanger J, 1946, A study of nerve degeneration and regeneration, Am J Physiol, 147, 550, 10.1152/ajplegacy.1946.147.3.550 · doi:10.1152/ajplegacy.1946.147.3.550
- 10.1016/0022-510X(81)90033-2 · DOI
- Gilliatt RW, 1975, Advances in Neurology, 253
- 10.1016/S0006-3495(74)85947-3 · DOI · Paper page
- 10.1083/jcb.88.1.205 · DOI
- Gutmann E, 1941, The rate of regeneration of nerve, J Exp Biol, 19, 14, 10.1242/jeb.19.1.14 · DOI · Paper page
- 10.1016/0165-0270(81)90033-9 · DOI
- 10.1016/0014-4886(65)90022-1 · DOI
- 10.1083/jcb.98.5.1685 · doi:10.1083/jcb.98.5.1685
- Kocsis JD, 1987, Progress in Brain Research, 89
- 10.1016/S0140-6736(46)90449-7 · doi:10.1016/s0140-6736(46)90449-7
- 10.1016/0022-510X(85)90045-0 · DOI
- Krarup C, 1983, Implanted electrodes for monitoring action potentials in regenerating cat nerves, Neurosci Abstr, 9, 50
- Krarup C, 1984, Multielektrodeuntersuchungen an regenerierenden Nerven
- Krarup C, 1986, Faster rate of regeneration in small than large myelinated fibers, Muscle Nerve, 9, 132
- 10.1016/S0006-3495(76)85719-0 · DOI
- 10.1136/jnnp.50.1.6 · doi:10.1136/jnnp.50.1.6
- 10.1016/0014-4886(84)90182-1 · DOI
- 10.1113/jphysiol.1951.sp004655 · DOI · Paper page
- 10.1016/0006-8993(72)90215-6 · DOI · Paper page
- 10.1113/jphysiol.1943.sp004027 · doi:10.1113/jphysiol.1943.sp004027
- 10.1016/0022-5193(71)90155-X · DOI
- Sunderland S, 1978, Nerves and Nerve Injuries, 82
- 10.1038/248740a0 · DOI · Paper page
- 10.1098/rspb.1985.0066 · DOI
- 10.1126/science.2409596 · DOI · Paper page
- Weiss P, 1948, Experiments on the mechanism of nerve growth, J Exp Biol, 107, 315
- 10.1016/0022-510X(77)90199-X · doi:10.1016/0022-510x(77)90199-x
- 10.1016/S0140-6736(01)07978-8 · DOI · Paper page
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Archibald, S. J., Krarup, C., Shefner, J., Li, S., & Madison, R. D. (1991) · Journal of Comparative Neurology · doi:10.1002/cne.903060410 · Cited by 374
Self-citationMonkey median nerve repaired by nerve graft or collagen nerve guide tube
Archibald, S., Shefner, J., Krarup, C., & Madison, R. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-05-04109.1995 · Cited by 359
Self-citationOutcome measures of peripheral nerve regeneration
Wood, M. D., Kemp, S. W. P., Weber, C., Borschel, G. H., & Gordon, T. (2011) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2011.04.008 · Cited by 264
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Krarup, C., Archibald, S. J., & Madison, R. D. (2002) · Annals of Neurology · doi:10.1002/ana.10054 · Cited by 172
Self-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54
Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff
Schuettler, M., Donaldson, N., Seetohul, V., & Taylor, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036016 · Cited by 50
Polymeric C-shaped cuff electrode for recording of peripheral nerve signal
Xue, N., Sun, T., Tsang, W. M., Delgado-Martinez, I., Lee, S.-H., Sheshadri, S., Xiang, Z., Merugu, S., Gu, Y., Yen, S.-C., et al. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.006 · Cited by 48
Krarup, C., Loeb, G. E., & Pezeshkpour, G. H. (1989) · Muscle & Nerve · doi:10.1002/mus.880121108 · Cited by 28
Self-citationHow to Use Nerve Cuffs to Stimulate, Record or Modulate Neural Activity
Hoffer, J.-A., & Kallesøe, K. (2000) · Frontiers in Neuroscience · doi:10.1201/9781420039054.ch5 · Cited by 21
The foreign body response and morphometric changes associated with mesh-style peripheral nerve cuffs
Christensen, M. B., & Tresco, P. A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.059 · Cited by 19
Metadata
- Authors
- Krarup, C., Loeb, G. E., & Pezeshkpour, G. H.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 1988-09
- Volume
- 11
- Issue
- 9
- Pages
- 933-944
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2156338930
- Cited by
- 66
- References
- 0
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.