In vivo magnetic resonance imaging and spectroscopy of humans with a 4 t whole‐body magnet
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A research‐type 4 T whole‐body magnet, built by Siemens AG, Erlangen, FRG, was used to investigate magnetic resonance at high field strengths. Designs for head and body coils operating at 170 MHz are described. Proton images of the human head and body are degraded by dielectric resonances and penetration effects. The nature of the dielectric resonances was demonstrated in phantoms containing distilled and saline doped water. Radiation damping at 170 MHz generates secondary echoes after a spin echo sequence. This effect was observed in phantoms and with reduced amplitude in the human head. Hydrogen spectra of the human head were selected utilizing stimulated and spin echoes. The latter technique allows the volume size to be reduced to 1 cm 3. Examples of brain tumors that have been routinely investigated with volumes of 8 cm 3 are given. Natural abundance carbon and phosphorus spectra of muscle and liver demonstrate the expected increase in spectral resolution and signal to noise ratio. Carbon spectra from the liver show the glycogen signal. Fluorine spectroscopy was used to study the time course of the absorption and emptying of a fluorinated antibiotic from the human stomach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Cited by
The Return of the Frequency Sweep: Designing Adiabatic Pulses for Contemporary NMR
Garwood, M., & DelaBarre, L. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2340 · Cited by 952
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Studies of human tumors by MRS: A review
Negendank, W. (1992) · NMR in Biomedicine · doi:10.1002/nbm.1940050518 · Cited by 660
B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
Safety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436
In vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394
“Preliminary results obtained in the late 1980s demonstrated the feasibility of in vivo (1)H NMR spectroscopy of human brain at 4 T and confirmed the expected increased sensitivity (6,7).”
High frequency volume coils for clinical NMR imaging and spectroscopy
Vaughan, J. T., Hetherington, H. P., Otu, J. O., Pan, J. W., & Pohost, G. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320209 · Cited by 374
9.4T human MRI: Preliminary results
Vaughan, T., DelaBarre, L., Snyder, C., Tian, J., Akgun, C., Shrivastava, D., Liu, W., Olson, C., Adriany, G., Strupp, J., et al. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21073 · Cited by 317
Analysis of wave behavior in lossy dielectric samples at high field
Yang, Q. X., Wang, J., Zhang, X., Collins, C. M., Smith, M. B., Liu, H., Zhu, X., Vaughan, J. T., Ugurbil, K., & Chen, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10137 · Cited by 255
Bernstein, M. A., Huston, J., & Ward, H. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20698 · Cited by 255
High contrast and fast three‐dimensional magnetic resonance imaging at high fields
Lee, J., Garwood, M., Menon, R., Adriany, G., Andersen, P., Truwit, C. L., & Uǧurbil, K. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340305 · Cited by 225
“We have previously demonstrated that when TMD = 27, signal generated with MDEFT contrast is relatively insensitive to B, variations; this is an important consideration, especially in high field applications where B, intensity is distorted because of dielectric resonances (6, 10).”
BackgroundAdriany, G., Van de Moortele, P., Ritter, J., Moeller, S., Auerbach, E. J., Akgün, C., Snyder, C. J., Vaughan, T., & Uğurbil, K. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21488 · Cited by 198
Imaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“6) was attributed to a “dielectric resonance” in the early 4 T work (Bomsdorf et al., 1988; Barfuss et al., 1990), and in work performed with electromagnetic simulations of the B1 field in the human head at 1.5, 3 and 6 T (Jin et al., 1996).”
BackgroundInfluentialIbrahim, T. S., Lee, R., Abduljalil, A. M., Baertlein, B. A., & Robitaille, P.-M. L. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00300-9 · Cited by 163
“[16] Barfuss H, Fischer H, Hentschel D, Ladebeck R, Oppelt A, Wittig R,”
BackgroundMethodHuman brain: Proton diffusion MR spectroscopy
Posse, S., Cuenod, C. A., & Le Bihan, D. (1993) · Radiology · doi:10.1148/radiology.188.3.8351339 · Cited by 122
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Metadata
- Authors
- Barfuss, H., Fischer, H., Hentschel, D., Ladebeck, R., Oppelt, A., Wittig, R., Duerr, W., & Oppelt, R.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 1990-02
- Volume
- 3
- Issue
- 1
- Pages
- 31-45
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2032313003
- Cited by
- 119
- References
- 1
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.