The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Arc‐Free Atmospheric Pressure Cold Plasma Jets: A Review
Abstract
Non‐thermal atmospheric pressure plasma jets/plumes are playing an increasingly important role in various plasma processing applications. This is because of their practical capability to provide plasmas that are not spatially bound or confined by electrodes. This capability is very desirable in many situations such as in biomedical applications. Various types of ‘cold’ plasma jets have, therefore, been developed to better suit specific uses. In this paper a review of the different cold plasma jets developed to date is presented. The jets are classified according to their power sources, which cover a wide frequency spectrum from DC to microwaves. Each jet is characterized by providing its operational parameters such as its electrodes system, plasma temperature, jet/plume geometrical size (length, radius), power consumption, and gas mixtures used. Applications of each jet are also briefly covered. magnified image
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The atmospheric-pressure plasma jet: a review and comparison to other plasma sources
Schutze, A., Jeong, J. Y., Babayan, S. E., Park, J., Selwyn, G. S., & Hicks, R. F. (1998) · IEEE Transactions on Plasma Science · doi:10.1109/27.747887 · Cited by 1,401
Low Temperature Plasma‐Based Sterilization: Overview and State‐of‐the‐Art
Laroussi, M. (2005) · Plasma Processes and Polymers · doi:10.1002/ppap.200400078 · Cited by 1,111
Self-citationMassines, F., Rabehi, A., Decomps, P., Gadri, R. B., Ségur, P., & Mayoux, C. (1998) · Journal of Applied Physics · doi:10.1063/1.367051 · Cited by 955
Laroussi, M. (2002) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2002.804220 · Cited by 760
Self-citationStable glow plasma at atmospheric pressure
Kanazawa, S., Kogoma, M., Moriwaki, T., & Okazaki, S. (1988) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/21/5/028 · Cited by 697
Room-temperature atmospheric pressure plasma plume for biomedical applications
Laroussi, M., & Lu, X. (2005) · Applied Physics Letters · doi:10.1063/1.2045549 · Cited by 637
Self-citationStoffels, E., Flikweert, A. J., Stoffels, W. W., & Kroesen, G. M. W. (2002) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/11/4/304 · Cited by 616
Generation of large-volume, atmospheric-pressure, nonequilibrium plasmas
Kunhardt, E. E. (2000) · IEEE Transactions on Plasma Science · doi:10.1109/27.842901 · Cited by 525
Sterilization of contaminated matter with an atmospheric pressure plasma
Laroussi, M. (1996) · IEEE Transactions on Plasma Science · doi:10.1109/27.533129 · Cited by 517
Self-citationRadio-Frequency Capacitive Discharges
Raǐzer, Y. P., Shneider, M. N., & Yatsenko, N. A. (2017) · CRC Press eBooks · doi:10.1201/9780203741337 · Cited by 368
Etching materials with an atmospheric-pressure plasma jet
Jeong, J. Y., Babayan, S. E., Tu, V. J., Park, J., Henins, I., Hicks, R. F., & Selwyn, G. S. (1998) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/7/3/005 · Cited by 316
Plasma Treatment of Dental Cavities: A Feasibility Study
Sladek, R. E. J., Stoffels, E., Walraven, R., Tielbeek, P. J. A., & Koolhoven, R. A. (2004) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2004.832636 · Cited by 253
Deposition of silicon dioxide films with an atmospheric-pressure plasma jet
Babayan, S. E., Jeong, J., Tu, V. J., et al. (1998) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/7/3/006 · Cited by 251
Inactivation of Bacteria by the Plasma Pencil
Laroussi, M., Tendero, C., Lu, X., Alla, S., & Hynes, W. L. (2006) · Plasma Processes and Polymers · doi:10.1002/ppap.200600005 · Cited by 222
Self-citationDeposition of silicon dioxide films with a non-equilibrium atmospheric-pressure plasma jet
Babayan, S. E., Jeong, J. Y., Schütze, A., Tu, V. J., Moravej, M., Selwyn, G. S., & Hicks, R. F. (2001) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/10/4/305 · Cited by 185
Development and application of a microbeam plasma generator
Koinuma, H., Ohkubo, H., Hashimoto, T., Inomata, K., Shiraishi, T., Miyanaga, A., & Hayashi, S. (1992) · Applied Physics Letters · doi:10.1063/1.106527 · Cited by 165
Reattachment and Apoptosis After Plasma-Needle Treatment of Cultured Cells
Kieft, I. E., Kurdi, M., & Stoffels, E. (2006) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2006.876511 · Cited by 162
Investigations of an atmospheric pressure plasma jet by optical emission spectroscopy
Förster, S., Mohr, C., & Viöl, W. (2005) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2005.02.217 · Cited by 146
Electrical and optical characterization of the plasma needle
Kieft, I. E., van der Laan, E. P., & Stoffels, E. (2004) · New Journal of Physics · doi:10.1088/1367-2630/6/1/149 · Cited by 141
Plasma treatment of mammalian vascular cells: a quantitative description
Kieft, I. E., Darios, D., Roks, A. J. M., & Stoffels, E. (2005) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2005.844528 · Cited by 135
Etching polyimide with a nonequilibrium atmospheric-pressure plasma jet
Jeong, J., Babayan, S. E., Schütze, A., Tu, V. J., Park, J., Henins, I., Selwyn, G. S., & Hicks, R. F. (1999) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.581999 · Cited by 125
Comparison of an atmospheric pressure, radio-frequency discharge operating in the α and γ modes
Yang, X., Moravej, M., Nowling, G. R., Babayan, S. E., Panelon, J., Chang, J. P., & Hicks, R. F. (2005) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/14/2/013 · Cited by 123
Glow Discharges Observed in Capacitive Radio‐Frequency Atmospheric‐Pressure Plasma Jets
Laimer, J., & Störi, H. (2006) · Plasma Processes and Polymers · doi:10.1002/ppap.200600046 · Cited by 47
Cited by
Lu, X., Naidis, G. V., Laroussi, M., Reuter, S., Graves, D. B., & Ostrikov, K. (2016) · Physics Reports · doi:10.1016/j.physrep.2016.03.003 · Cited by 1,230
Self-citationvon Woedtke, T., Reuter, S., Masur, K., & Weltmann, K.-D. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.05.005 · Cited by 848
On atmospheric-pressure non-equilibrium plasma jets and plasma bullets
Lu, X., Laroussi, M., & Puech, V (2012) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/21/3/034005 · Cited by 844
Self-citationBrandenburg, R. (2017) · Plasma Sources Science and Technology · doi:10.1088/1361-6595/aa6426 · Cited by 802
Low-Temperature Plasmas for Medicine?
Laroussi, M. (2009) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2009.2017267 · Cited by 619
Self-citation
Metadata
- Authors
- Laroussi, M., & Akan, T.
- Venue
- Plasma Processes and Polymers
- Publisher
- Wiley
- Published
- 2007-11-12
- Volume
- 4
- Issue
- 9
- Pages
- 777-788
- ISSN
- 1612-8850 (ISSN-L)
- 1612-8869
- OpenAlex
- W2083720483
- Cited by
- 699
- References
- 23
- FWCI
- 15.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.