Transportable Strontium Optical Lattice Clocks Operated Outside Laboratory at the Level of 10 −18 Uncertainty
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Transportable strontium optical lattice clocks are developed with a fractional uncertainty of 5.5 × 10 −18 for applications outside laboratories. A single clock consists of a spectroscopy chamber and two laser boxes, where all lasers are based on external cavity diode lasers with an adjustment‐free, laser‐welded output coupler. When this system is transported from the laboratory at RIKEN to a broadcasting tower, the instruments experience acceleration change of 4 G at maximum. However, no serious optical misalignments are found. The demonstration opens up field applications of optical atomic clocks resolving a centimeter height difference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Today, several groups operate transportable optical clocks [16, 17, 25-31].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Self-citationTest of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Self-citationGeodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Research works printed but not linked: 4
- C W Chou, D B Hume, J C J Koelemeij, D J Wineland, T Rosenband, Phys. Rev. Lett. 10470802C. W. Chou, D. B. Hume, J. C. J. Koelemeij, D. J. Wineland, T. Rosen- band, Phys. Rev. Lett. 2020, 104, 070802.
- Adv. Quantum Technol. 20212100015Adv. Quantum Technol. 2021, 4, 2100015
- D B Hassan, D Hume, C J Kedar, I Kennedy, A Khader, D R Koepke, H Leibrandt, A D Leopardi, W F Ludlow, W R Mcgrew, N R Milner, D Newbury, E Nicolodi, T E Oelker, J M Parker, S Robinson, S A Romisch, J A Schäffer, L C Sherman, Sinclair, Nature. 564Hassan, D. B. Hume, D. Kedar, C. J. Kennedy, I. Khader, A. Koepke, D. R. Leibrandt, H. Leopardi, A. D. Ludlow, W. F. McGrew, W. R. Milner, N. R. Newbury, D. Nicolodi, E. Oelker, T. E. Parker, J. M. Robinson, S. Romisch, S. A. Schäffer, J. A. Sherman, L. C. Sinclair, et al., Nature 2021, 591, 564.
- H S Bayne, P Margolis, Gill, Phys. Rev. Lett. 221102Bayne, H. S. Margolis, P. Gill, Phys. Rev. Lett. 2017, 118, 221102.
Cited by
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 211
“An accuracy ranging from 10 − 15 down to parts in 10 18 has been reported for several 87 Sr TOCs [86–88].”
BackgroundKobayashi, T., Takamizawa, A., Akamatsu, D., Kawasaki, A., Nishiyama, A., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Tanabe, T., et al. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.241301 · Cited by 66
Coherence limits in lattice atom interferometry at the one-minute scale
Panda, C. D., Tao, M., Egelhoff, J., Ceja, M., Xu, V., & Müller, H. (2024) · Nature Physics · doi:10.1038/s41567-024-02518-9 · Cited by 61
“For example, optical lattice clocks with atoms trapped for 15 s have enabled 2–3 orders of magnitude gains 1,2 in precision relative to atomic fountain clocks.”
A strontium lattice clock with both stability and uncertainty below 5 × 10 − 18
Li, J., Cui, X.-Y., Jia, Z.-P., Kong, D.-Q., Yu, H.-W., Zhu, X.-Q., Liu, X., Wang, D., Zhang, X., Huang, X.-Y., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad1a4c · Cited by 58
A lab-based test of the gravitational redshift with a miniature clock network
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023) · Nature Communications · doi:10.1038/s41467-023-40629-8 · Cited by 47
Measurement of Optical Rubidium Clock Frequency Spanning 65 Days
Lemke, N., Martin, K. W., Beard, R., Stuhl, B., Metcalf, A. J., & Elgin, J. (2022) · Sensors · doi:10.3390/s22051982 · Cited by 48
Schkolnik, V., Budker, D., Fartmann, O., Flambaum, V. V., Hollberg, L. W., Kalaydzhyan, T., Kolkowitz, S., Krutzik, M., Ludlow, A. D., Newbury, N. R., et al. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac9f2b · Cited by 47
“Adaptations that might be beneficial for OACESS, like a pyramidal single beam 3D-MOT assembly or an integrated enhancement cavity for the optical lattice will be investigated [53, 54].”
BackgroundTerahertz Vibrational Molecular Clock with Systematic Uncertainty at the 10−14 Level
Leung, K. H., Iritani, B., Tiberi, E., Majewska, I., Borkowski, M., Moszyński, R., & Zelevinsky, T. (2023) · Physical Review X · doi:10.1103/physrevx.13.011047 · Cited by 50
A perspective on the future of transportable optical lattice clocks
Takamoto, M., Tanaka, Y., & Katori, H. (2022) · Applied Physics Letters · doi:10.1063/5.0087894 · Cited by 40
Self-citationPound–Drever–Hall feedforward: laser phase noise suppression beyond feedback
Chao, Y.-X., Hua, Z.-X., Liang, X.-H., Yue, Z.-P., You, L., & Tey, M. K. (2024) · Optica · doi:10.1364/optica.516838 · Cited by 45
Long-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
Two-Color Grating Magneto-Optical Trap for Narrow-Line Laser Cooling
Bondza, S., Lisdat, C., Kroker, S., & Leopold, T. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.044002 · Cited by 34
Pathway toward Optical Cycling and Laser Cooling of Functionalized Arenes
Mitra, D., Lasner, Z., Zhu, G., Dickerson, C. E., Augenbraun, B. L., Bailey, A., Alexandrova, A. N., Campbell, W. C., Caram, J. R., Hudson, E. R., et al. (2022) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.2c01430 · Cited by 27
Cold atoms in space: community workshop summary and proposed road-map
Alonso, I., Alpigiani, C., Altschul, B., Araújo, H. M., Arduini, G., Arlt, J., Badurina, L., Balaž, A., Bandarupally, S., Barish, B. C., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00147-w · Cited by 61
Toward a New Generation of Compact Transportable Yb+ Optical Clocks
Khabarova, K. Y., Kryuchkov, D. S., Borisenko, A., Zalivako, I. V., Semerikov, I. A., Aksenov, M. A., Sherstov, I., Abbasov, T., Tausenev, A. V., & Kolachevsky, N. (2022) · Symmetry · doi:10.3390/sym14102213 · Cited by 28
Toward a Transportable Ca+ Optical Clock with a Systematic Uncertainty of 4.8 × 10 −18
Zeng, M., Huang, Y., Zhang, B., Hao, Y., Ma, Z., Hu, R., Zhang, H., Chen, Z., Wang, M., Guan, H., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064004 · Cited by 23
Optical atomic clocks: defining the future of time and frequency metrology
Fortier, T. M., Luiten, A. N., & Margolis, H. S. (2026) · Optica · doi:10.1364/optica.575770 · Cited by 46
Grating magneto-optical traps with complicated level structures
Barker, D. S., Elgee, P. K., Sitaram, A., Norrgard, E. B., Klimov, N. N., Campbell, G. K., & Eckel, S. (2023) · New Journal of Physics · doi:10.1088/1367-2630/ad02ea · Cited by 23
Time Synchronization in Communication Networks: A Comparative Study of Quantum Technologies
Nande, S. S., Garbugli, A., Bassoli, R., & Fitzek, F. H. P. (2024) · IEEE Wireless Communications and Networking Conference · doi:10.1109/wcnc57260.2024.10570688 · Cited by 26
“3) Potential for Miniaturization and Portability: Recent advancements in solid-state laser technologies, optical components, and materials science have opened the door for miniaturized, portable versions of optical lattice clocks [33].”
BackgroundMa, Z., Deng, K., Wang, Z. Y., Wei, W. Z., Hao, P., Zhang, H. X., Pang, L., Wang, B., Wu, F.-F., Liu, H. L., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.044017 · Cited by 26
Xiao, R., Xu, Y., Wang, Y., Sun, H., & Chen, Q. (2022) · Applied Physics B · doi:10.1007/s00340-022-07938-0 · Cited by 20
Optically Loaded Strontium Lattice Clock With a Single Multi-Wavelength Reference Cavity
Barbiero, M., Calonico, D., Levi, F., & Tarallo, M. G. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3165292 · Cited by 22
“Previous approaches to build compact and transportable OLCs tackled this problem by simplifying the frequency stabilization scheme either by employing a monolithic multicavity [13], by sub-harmonic frequency dissemination of remote frequency references on a telecom network and subsequent optical phase-locked loops [14…”
BackgroundMethodQuantum information technology: Current status and prospects
Pan, J.-W. (2023) · Acta Physica Sinica · doi:10.7498/aps.73.20231795 · Cited by 18
Precision measurement of M1 optical clock transition in Ni12+
Chen, S., Zhou, Z., Li, J., Zhang, T., Li, C., Shi, T.-Y., Huang, Y., Gao, K., & Guan, H. (2024) · Physical Review Research · doi:10.1103/physrevresearch.6.013030 · Cited by 15
Transportable strontium lattice clock with 4 × 10 − 19 blackbody radiation shift uncertainty
Nosske, I., Vishwakarma, C., Lücke, T., Rahm, J., Poudel, N., Weyers, S., Benkler, E., Dörscher, S., & Lisdat, C. (2025) · Quantum Science and Technology · doi:10.1088/2058-9565/ae1161 · Cited by 19
Robust suppression of high-frequency laser phase noise by adaptive Pound-Drever-Hall feedforward
Chao, Y.-X., Hua, Z.-X., Liang, X.-H., Yue, Z.-P., Chen, J., You, L., & Tey, M. K. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.l011005 · Cited by 18
Sub-kilohertz linewidth free-running monolithic cavity VECSEL with 10−12 stability
Moriya, P. H., Lee, M., & Hastie, J. E. (2024) · Applied Physics Letters · doi:10.1063/5.0208564 · Cited by 12
An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity
Zhu, X.-Q., Cui, X.-Y., Kong, D.-Q., Yu, H.-W., Zhai, X., Zheng, M.-Y., Xie, X.-P., Zhang, Q., Jiang, X. Q., Zhang, X., et al. (2024) · Review of Scientific Instruments · doi:10.1063/5.0200553 · Cited by 13
Obaze-Adeleke, A. C., Semon, B., & Bandi, T. (2025) · Photonics · doi:10.3390/photonics12050513 · Cited by 14
Compact structures for single-beam magneto-optical trapping of ytterbium
Pick, J., Schwarz, R., Kruse, J., Lisdat, C., & Klempt, C. (2024) · Review of Scientific Instruments · doi:10.1063/5.0203308 · Cited by 11
Testing screened scalar-tensor theories of gravity with atomic clocks
Lévy, H., & Uzan, J. (2025) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.111.064012 · Cited by 11
“They achieve relative frequency precisions of 10 − 18 and below [75–79], down to 7 .”
High Power Distributed Bragg Reflector Lasers at 689.45 nm for Quantum Technology Applications
Pyrlik, C., Goossen-Schmidt, N., Hassan, M. T., Bawamia, A., Fricke, J., Knigge, A. C., Maaßdorf, A., Schiemangk, M., Wenzel, H., & Wicht, A. (2021) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2021.3139433 · Cited by 11
Stability improvement of 40 Ca + optical clock by using a transportable ultra-stable cavity
Hao, Y., Hu, R., Zhang, B., Zeng, M., Zhang, H., Ma, Z., Huang, Y., Chen, Q., Gao, K., & Guan, H. (2024) · Optics Express · doi:10.1364/oe.509502 · Cited by 13
An integrated high-flux cold atomic beam source for strontium
Li, J., Jia, Z.-P., Liu, P., Liu, X., Wang, D., Kong, D.-Q., Li, S.-M., Cui, X.-Y., Dai, H.-N., Chen, Y.-A., et al. (2023) · Review of Scientific Instruments · doi:10.1063/5.0162128 · Cited by 12
Kraus, B., Herbers, S., Nauk, C., Sterr, U., Lisdat, C., & Schmidt, P. O. (2025) · Optics Letters · doi:10.1364/ol.544907 · Cited by 12
Low-power microstructured atomic oven for alkaline-earth-like elements
Pick, J., Voß, J., Hirt, S., Kruse, J., Leopold, T., Schwarz, R., & Klempt, C. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.014020 · Cited by 7
Optical cavities for frequency discrimination: Advances and perspectives
Fan, W., Zhang, L., Chen, H., Zhang, C., Chen, Y., Li, T., Wang, Y., Lü, Z., & Bai, Z. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117242 · Cited by 6
International optical clock comparison using the European optical fiber network
Anonymous, Zyskind, C., Amy‐Klein, A., Benkler, E., Bize, S., Calonico, D., Cantin, E., Chardonnet, C., Clivati, C., Condio, S., et al. (2026) · Physical Review Research · doi:10.1103/l4bh-ryxs · Cited by 8
“…work we report on a clock comparison campaign involving 7 optical clocks in Another campaign was also running in March and April 2023 for the project ICON [48] involving NPL-Sr1 and PTB-Sr3 as well as the transportable 87 Sr optical lattice clocks developed at PTB [49] and RIKEN in Japan [14, 50].”
Limitation of single-repumping schemes for laser cooling of Sr atoms
Okamoto, N., Aoki, T., & Torii, Y. (2024) · Physical Review Research · doi:10.1103/physrevresearch.6.043088 · Cited by 6
Yang, H., Lu, C., Zhang, W., Li, X., Qi, M., Han, D., Wang, P., Xie, Y., Li, L., & Zhao, F. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c13636 · Cited by 6
Laser system of cold atom optical clock in China Space Station
Liu, Y., Wang, W., He, D., Zhou, Y., Shen, Y., & Zou, H. (2023) · Acta Physica Sinica · doi:10.7498/aps.72.20230412 · Cited by 6
A combined magnetic field stabilization system for improving the stability of 40Ca+ optical clock
Zeng, M., 马, Z. 子. M., Hu, R., 张, B. 宝. Z., 郝, Y. 艳. H., 张, H. 华. Z., 黄, Y. 垚. H., Guan, H., & 高, K. 克. G. (2023) · Chinese Physics B · doi:10.1088/1674-1056/acf5d5 · Cited by 6
Dawel, F., Wilzewski, A., Herbers, S., Pelzer, L., Kramer, J., Hild, M. B., Dietze, K., Krinner, L., Spethmann, N., & Schmidt, P. O. (2024) · Optics Express · doi:10.1364/oe.516433 · Cited by 7
“Apart from laboratory experiments in well-controlled environments, a rising number of trans-portable optical clocks [16, 17, 18, 19, 20, 21, 22, 23] also have clock laser stabilisation cavities with instabilities below 1 .”
BackgroundTransportable optical lattice clocks and general relativity
Shinkai, H.-A., Takamoto, M., & Katori, H. (2025) · International Journal of Modern Physics D · doi:10.1142/s0218271825400127 · Cited by 6
Self-citationProbe-Field-Ellipticity-Induced Shift in an Atomic Clock
Yudin, V. I., Taǐchenachev, A. V., Prudnikov, O. N., Basalaev, M. Y., Pal'chikov, V. G., von Boehn, M., Mehlstäubler, T. E., & Bagayev, S. N. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.014022 · Cited by 6
Compact magneto-optical traps using planar optics
谭, Z. 智. T., 鹿, B. 博. L., 韩, C. 成. H., & Lee, C. (2024) · Chinese Physics B · doi:10.1088/1674-1056/ad607a · Cited by 6
Suppressing background spectra of lattice lasers in strontium optical clocks
Jia, Z.-P., Cui, X.-Y., Xie, Y.-J., Zhang, X., Niu, G.-Z., Liu, X.-Y., Zhu, Q., Li, J., & Dai, H.-N. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.014014 · Cited by 6
Accurate Determination of Blackbody Radiation Shifts in a Strontium Molecular Lattice Clock
Iritani, B., Tiberi, E., Skomorowski, W., Moszyński, R., Borkowski, M., & Zelevinsky, T. (2023) · Physical Review Letters · doi:10.1103/physrevlett.131.263201 · Cited by 6
Magneto-optical trap with a hollow grating and an additional retroreflected laser beam
Takamizawa, A., Hokari, R., Kagami, S., Le, T. H. H., Matsumoto, K., Takei, R., Hagimoto, K., & Yanagimachi, S. (2025) · Applied Physics Letters · doi:10.1063/5.0250597 · Cited by 5
Compact strontium atomic beam source based on a two-dimensional grating magneto-optical trap
Lee, H. G., Park, Y., Park, C. Y., Seo, M. H., Hong, H.-G., Lee, S.-B., Kwon, T. Y., Kang, S., Seo, S., Park, S. E., et al. (2025) · Physical Review Applied · doi:10.1103/htx8-dr68 · Cited by 4
DSAC and next generation high stability, long life trapped mercury ion frequency standards
Burt, E. A., Ely, T., & Tjoelker, R. L. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012014 · Cited by 4
The Benefit of Space Clocks for the Deep Space Network
Ely, T., Burt, E. A., Cheung, K. M., & Tjoelker, R. L. (2025) · Radio Science · doi:10.1029/2025rs008244 · Cited by 4
“Much progress has been made on portable optical clocks (Ohmae et al., 2021), however they have not yet achieved the maturity or SWaP to be considered for GNSS.”
A Laser Based Universal Oscillator for Next Generation Optical Frequency Standards
Ghosh, S., Panja, S., & Das, M. (2023) · MAPAN · doi:10.1007/s12647-023-00651-z · Cited by 3
Direct loading of a Sr magneto-optical trap from a thermal atomic beam
Okamoto, N., Sato, T., Aoki, T., & Torii, Y. (2026) · Review of Scientific Instruments · doi:10.1063/5.0311769 · Cited by 3
“However, field-deployable and space-borne optical lattice clocks 10,32–37 demand stringent constraints on size, weight, and power (SWaP) 38 .”
Rack-Mounted Ultrastable Laser System for Sr Lattice Clock Operation
Brekenfeld, M., Rauf, B., Saint-Jalm, S., Cole, G. D., Truong, G.-W., Lessing, M., Fricke, A., Fischer, M., Giunta, M., & Holzwarth, R. (2022) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2022.stu5o.7 · Cited by 3
A multi-loop auto-locking system with fully digital electronics for ultra-stable laser
Xia, C., Zhu, D., Hu, Y., Wang, S., Guan, J.-Y., Hou, L., Shen, Q., & Jiang, H. (2025) · Review of Scientific Instruments · doi:10.1063/5.0274571 · Cited by 2
Andeweg, Y., Kitching, J. E., & Hummon, M. T. (2026) · Physical Review Applied · doi:10.1103/25md-vv43 · Cited by 3
“Optical atomic clocks represent the state of the art in precision timekeeping, with several advanced, laboratory-based optical clocks achieving a systematic fractional frequency instability at the 10 level [1–4].”
Zhu, Q., Shi, J., Zhang, Y., Xu, X., Wang, B., Xiong, D., Xiong, Z.-X., Fang, P., Chen, Q., He, L., et al. (2026) · Metrologia · doi:10.1088/1681-7575/aeb809 · Cited by 3
Ogawa, H., Kemmochi, T., & Takano, T. (2022) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ac956a · Cited by 2
Development of Compact and Robust Physical System for Strontium Optical Lattice Clock
Chen, Y.-X., Zhou, C., Tan, W., Guo, F., Zhao, G., Xia, J. G., Meng, J., & Chang, H. (2024) · Applied Sciences · doi:10.3390/app14041551 · Cited by 4
Low-noise fiber laser systems at 689 nm and 698 nm for strontium
Pertoldi, A., Jha, A., Hauge, J. M., Wayland, J., Kale, Y. B., Singh, Y., Montague, P. B., & Varming, P. (2025) · Optics Express · doi:10.1364/oe.555332 · Cited by 2
A magneto-optically pumped cesium beam clock using monochromatic light
Liu, C., Li, Y., Xiang, T., Feng, C., Lyu, H., Li, C., & Wang, Y. (2025) · Applied Physics Letters · doi:10.1063/5.0268775 · Cited by 1
Power stabilization method of a diode laser for compact vapor cell frequency standards
Baek, J., Choi, S., Kang, S., Park, S. E., Seo, M., Kwon, T. Y., Lee, S.-B., Lee, J. H., Park, Y., Seo, S., et al. (2026) · Optics Continuum · doi:10.1364/optcon.585779 · Cited by 1
Precision timekeeping with atomic clocks: evolution and future directions
Bisht, A., Arora, P., & Achanta, V. G. (2026) · Nature Communications · doi:10.1038/s41467-026-73441-1 · Cited by 1
“Commercial optical clocks, measurement of thorium nuclear transition frequency for a futuristic nuclear clock 100,101 .”
Burt, E. A., Ely, T., Bower, G. C., Lazio, T. J. W., Anderson, M. M., & Hernandez, S. (2026) · Radio Science · doi:10.1029/2025rs008476 · Cited by 2
“However, in the last few years there have been many efforts to make them portable (Brand et al., 2019; Ohmae et al., 2021; Stuhler et al., 2021).”
Xiao, 张. Z., Xin, 王. W., Wenli, 王. W., Yuan, 孙. S., & Liang, 刘. L. (2024) · Acta Optica Sinica · doi:10.3788/aos231382 · Cited by 1
Miniaturized Laser Distribution Module for Compact Sr-Based Optical Atomic Clocks
Hamperl, J., Goossen-Schmidt, N., Arar, B., Bursy, M., Hariharan, S., Müller, N., Schiemangk, M., Szermer, S., Tyborski, C., Zou, D., et al. (2024) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2024.jw2a.90 · Cited by 1
Distributed Bragg Reflector Lasers at 689.45 nm for Sr Spectroscopy
Goossen-Schmidt, N., Pyrlik, C., Hassan, M. T., Bawamia, A., Fricke, J., Knigge, A. C., Maaßdorf, A., Schiemangk, M., Wenzel, H., & Wicht, A. (2022) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2022.am2d.2
Red-Emitting Distributed Bragg Reflector Lasers for Strontium-Based Optical Atomic Clocks
Goossen-Schmidt, N., Pyrlik, C., Arar, B., Hassan, M. T., Bawamia, A., Fricke, J., Knigge, A. C., Maaßdorf, A., Schiemangk, M., Wenzel, H., et al. (2023) · Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC) · doi:10.1109/cleo/europe-eqec57999.2023.10232507
“They reach fractional frequency uncertainties in the range of 10−18 [1], which makes them promising candidates for the redefinition of the second and for improving, for example, the accuracy of satellite navigation.”
BackgroundOptical lattice clocks and related platforms
Takamoto, M., & Katori, H. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-98378-5.00002-7 · Cited by 1
Self-citationA digital control for the Ultra-Stable Laser system
Zhu, D., Shen, Q., Xia, C., Wang, S., Hou, L., Guan, J.-Y., & Jiang, H. (2024) · IEEE Ultrasonics, Ferroelectrics, and Frequency Control Joint Symposium (UFFC-JS) · doi:10.1109/uffc-js60046.2024.10793563
DBR Lasers at 679.29 and 707.20 nm for Efficient Repumping in Sr Optical Lattice Clocks
Goossen-Schmidt, N., Arar, B., Fricke, J., Häusler, K., Maaßdorf, A., Schiemangk, M., Szermer, S., Wenzel, H., & Wicht, A. (2025) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2025.3591153
“5 × 10 − 18 [1], they have the potential for many promising applications, such as the redefinition of the second [2], improved satellite navigation and fundamental research [3].”
KONG, 孔. D.-H., WANG, 王. Z.-H., Liang, T., Feng, M., GUO, 郭. F., WANG, 王. Y.-B., & CHANG, 常. H. (2023) · Acta Sinica Quantum Optica · doi:10.3788/jqo20232902.0201
WANG, 王. D.-Z., LIU, 刘. X.-Y., LI, 李. J., JIA, 贾. Z.-P., Zhang, 张. Y.-C., & Hanning, D. (2024) · Acta Sinica Quantum Optica · doi:10.3788/jqo20243004.0602
JIANG, 江. Z.-W., TANG, 唐. Y., HUANG, 黄. P., WANG, 王. B., ZHU, 朱. Q., & Xiong, Z.-X. (2024) · Acta Sinica Quantum Optica · doi:10.3788/jqo20243004.0601
Anderson, D. Z., Chomaz, P., Takeuchi, S., Arakawa, Y., Baba, Y., Benson, O. J., Soderberg, K.-A., Diamanti, E., Elkouss, D., Fujii, K., et al. (2026) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ae271a
Self-citationPlanar structures for two-color, single-beam magneto-optical traps
Bondza, S. (2023) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/14086 · Cited by 1
Verification of Gravitational Redshift Using Transportable Optical Lattice Clocks
Ohmae, N., Takamoto, M., Ushijima, I., & Katori, H. (2023) · The Review of Laser Engineering · doi:10.2184/lsj.51.8_506
Self-citationUltra-low noise diode lasers for quantum applications
Kolodzie, N. (2025) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/19439
Diffraction-Engineered Metasurfaces in Magneto-Optical Trapping toward Compact Cold Atom Systems
Le, T. H. H., Kagami, S., Takei, R., Matsumoto, K., Takamizawa, A., Kurashima, Y., & Motomura, T. (2026) · ACS Photonics · doi:10.1021/acsphotonics.6c00215 · Cited by 2
Maddaloni, P., Consolino, L., & Natale, P. D. (2025) · Springer series on atomic, optical, and plasma physics · doi:10.1007/978-3-031-99439-5_5
Narrow-linewidth Brillouin laser for a two-photon rubidium frequency standard
Anonymous, Beard, R., Isichenko, A., Liu, K., Blumenthal, D. J., Erickson, S. E., Campbell, K., & Krzyzewski, S. (2026) · Physical Review Applied · doi:10.1103/vgf7-kjlg
Nakamura, K., Nagase, S., Nakashita, T., Hayamizu, T., Aoki, T., Nagahama, H., Ozawa, N., Sato, M., Yamane, K., Fukase, M., et al. (2026) · Review of Scientific Instruments · doi:10.1063/5.0328467
Hu, R., Ma, Z., Zhang, B., Zhang, H., Wang, Y., Fang, P., Zhang, Y., Hu, Y., Wang, X., Wu, M., et al. (2026) · New Journal of Physics · doi:10.1088/1367-2630/ae9c68
“These advances are driving optical clocks beyond the laboratory and into practical applications, leading to growing interest in transportable optical clocks as an essential step toward deploying laboratory-grade precision in real-world environments [19–23].”
Miniaturized vacuum package for magneto-optical trapping of strontiumPreprint
Pick, J., Henker, E., Löwinger, F., Vogt, R., Hüttl, S., Trützschler, A., Voß, J., Hirt, S., Schulz‐Ruhtenberg, M., Buchta, A., et al. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2609.09846
Salvatierra, J. P. (2026) · PORTO@Iris · Cited by 1
Metadata
- Authors
- Ohmae, N., Takamoto, M., Takahashi, Y., Kokubun, M., Araki, K., Hinton, A., Ushijima, I., Muramatsu, T., Furumiya, T., Sakai, Y., Moriya, N., Kamiya, N., Fujii, K., Muramatsu, R., Shiimado, T., & Katori, H.
- Affiliations
- Fukuoka University (JP)
- RIKEN (JP)
- Japan Aerospace Exploration Agency (JP)
- RIKEN Center for Advanced Photonics (JP)
- Shimadzu (Japan) (JP)
- Equos Research Co., Ltd. 1‐18‐13 Sotokanda Chiyoda‐ku Tokyo 101‐0021 Japan
- Corresponding author
- Ohmae, Noriaki
- Venue
- Advanced Quantum Technologies
- Publisher
- Wiley
- Published
- 2021-05-31
- Volume
- 4
- Issue
- 8
- ISSN
- 2511-9044 (ISSN-L)
- OpenAlex
- W3171777338
- Cited by
- 79
- References
- 43
- Citations by year
- 2026: 7 · 2025: 17 · 2024: 24 · 2023: 16 · 2022: 14 · 2021: 1
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Advanced Quantum Technologies (publishedVersion, cc-by-nc-nd)
- Funders
- Japan Society for the Promotion of Science (JP16H06284)
- Japan Science and Technology Agency (JPMJMI18A1)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- strontium optical lattice clock, external cavity diode laser, fractional frequency uncertainty, acceleration tolerance, optical misalignment, height difference measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.