Transportable Strontium Optical Lattice Clocks Operated Outside Laboratory at the Level of 10 −18 Uncertainty
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Transportable strontium optical lattice clocks are developed with a fractional uncertainty of 5.5 × 10 −18 for applications outside laboratories. A single clock consists of a spectroscopy chamber and two laser boxes, where all lasers are based on external cavity diode lasers with an adjustment‐free, laser‐welded output coupler. When this system is transported from the laboratory at RIKEN to a broadcasting tower, the instruments experience acceleration change of 4 G at maximum. However, no serious optical misalignments are found. The demonstration opens up field applications of optical atomic clocks resolving a centimeter height difference.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Today, several groups operate transportable optical clocks [16, 17, 25-31].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [27]
Citations
Cites
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Self-citationTest of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Self-citationGeodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Deterministic Delivery of a Single Atom
Kuhr, S., Alt, W., Schrader, D., Müller, M., Gomer, V., & Meschede, D. (2001) · Science · doi:10.1126/science.1062725 · Cited by 259
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Geopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245
Self-citationTransportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Test of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Self-citationGravitational Redshift Test Using Eccentric Galileo Satellites
Delva, P., Puchades, N., Schönemann, E., Dilssner, F., Courde, C., Bertone, S., Gonzalez, F., Hees, A., Le Poncin-Lafitte, C., Meynadier, F., et al. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.231101 · Cited by 210
Test of the Gravitational Redshift with Galileo Satellites in an Eccentric Orbit
Herrmann, S., Finke, F., Lülf, M., Kichakova, O., Puetzfeld, D., Knickmann, D., List, M., Rievers, B., Giorgi, G., Günther, C., et al. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.231102 · Cited by 175
Frequency comparison of optical lattice clocks beyond the Dick limit
Takamoto, M., Takano, T., & Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.34 · Cited by 154
Self-citationOriglia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Recoil-Limited Laser Cooling ofSr87Atoms near the Fermi Temperature
Mukaiyama, T., Katori, H., Ido, T., Li, Y., & Kuwata-Gonokami, M. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.113002 · Cited by 131
Self-citationTakamoto, M., Hong, F.-L., Higashi, R., Fujii, Y., Imae, M., & Katori, H. (2006) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.75.104302 · Cited by 125
Self-citationOperational Magic Intensity for Sr Optical Lattice Clocks
Ushijima, I., Takamoto, M., & Katori, H. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.263202 · Cited by 111
Self-citationFrequency Ratio ofHg199andSr87Optical Lattice Clocks beyond the SI Limit
Yamanaka, K., Ohmae, N., Ushijima, I., Takamoto, M., & Katori, H. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.230801 · Cited by 104
Self-citationA compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Interference-filter-tuned, alignment-stabilized, semiconductor external-cavity laser
Zorabedian, P., & Trutna, W. R. (1988) · Optics Letters · doi:10.1364/ol.13.000826 · Cited by 61
Ground-based optical atomic clocks as a tool to monitor vertical surface motion
Bondarescu, R., Schärer, A., Lundgren, A., Hetényi, G., Houlié, N., Jetzer, P., & Bondarescu, M. (2015) · Geophysical Journal International · doi:10.1093/gji/ggv246 · Cited by 56
Optical frequency distribution using laser repeater stations with planar lightwave circuits
Akatsuka, T., Goh, T., Imai, H., Oguri, K., Ishizawa, A., Ushijima, I., Ohmae, N., Takamoto, M., Katori, H., Hashimoto, T., et al. (2020) · Optics Express · doi:10.1364/oe.383526 · Cited by 55
Self-citationOptical frequency ratio of a 171Yb+ single-ion clock and a 87Sr lattice clock
Dörscher, S., Huntemann, N., Schwarz, R., Lange, R., Benkler, E., Lipphardt, B., Sterr, U., Peik, E., & Lisdat, C. (2021) · Metrologia · doi:10.1088/1681-7575/abc86f · Cited by 53
Geopotential measurement with a robust, transportable Ca+ optical clock
Huang, Y., Zhang, H., Zhang, B., Hao, Y., Guan, H., Zeng, M., Chen, Q., Lin, Y., Wang, Y., Cao, S., et al. (2020) · Physical Review A · doi:10.1103/physreva.102.050802 · Cited by 52
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
Transportable interrogation laser system with an instability of mod σy = 3 × 10−16
Häfner, S., Herbers, S., Vogt, S., Lisdat, C., & Sterr, U. (2020) · Optics Express · doi:10.1364/oe.390105 · Cited by 37
Ohmae, N., Bregolin, F., Nemitz, N., & Katori, H. (2020) · Optics Express · doi:10.1364/oe.391602 · Cited by 36
Self-citationTakano, T., Mizushima, R., & Katori, H. (2017) · Applied Physics Express · doi:10.7567/apex.10.072801 · Cited by 35
Self-citationMultipole, nonlinear, and anharmonic uncertainties of clocks of Sr atoms in an optical lattice
Ovsiannikov, V. D., Pal'chikov, V. G., Taichenachev, A. V., Yudin, V. I., & Katori, H. (2013) · Physical Review A · doi:10.1103/physreva.88.013405 · Cited by 33
Self-citationClocks in Space for Tests of Fundamental Physics
Delva, P., Hees, A., & Wolf, P. (2017) · Space Science Reviews · doi:10.1007/s11214-017-0361-9 · Cited by 29
Characterization and Suppression of Background Light Shifts in an Optical Lattice Clock
Fasano, R., Chen, Y.-J., McGrew, W. F., Brand, W., Fox, R. W., & Ludlow, A. D. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.044016 · Cited by 26
Three-stage laser cooling of Sr atoms using the 5s5pP23 metastable state below Doppler temperatures
Akatsuka, T., Hashiguchi, K., TAKAHASHI, T., Ohmae, N., Takamoto, M., & Katori, H. (2021) · Physical Review A · doi:10.1103/physreva.103.023331 · Cited by 22
Self-citationHigh‐stability optical frequency transfer with all‐fiber architecture for optical lattice clocks
Ohmae, N., Sakama, S., & Katori, H. (2019) · Electronics and Communications in Japan · doi:10.1002/ecj.12167 · Cited by 6
Self-citation
Cited by
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 211
“An accuracy ranging from 10 − 15 down to parts in 10 18 has been reported for several 87 Sr TOCs [86–88].”
BackgroundKobayashi, T., Takamizawa, A., Akamatsu, D., Kawasaki, A., Nishiyama, A., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Tanabe, T., et al. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.241301 · Cited by 66
Coherence limits in lattice atom interferometry at the one-minute scale
Panda, C. D., Tao, M., Egelhoff, J., Ceja, M., Xu, V., & Müller, H. (2024) · Nature Physics · doi:10.1038/s41567-024-02518-9 · Cited by 61
“For example, optical lattice clocks with atoms trapped for 15 s have enabled 2–3 orders of magnitude gains 1,2 in precision relative to atomic fountain clocks.”
A strontium lattice clock with both stability and uncertainty below 5 × 10 − 18
Li, J., Cui, X.-Y., Jia, Z.-P., Kong, D.-Q., Yu, H.-W., Zhu, X.-Q., Liu, X., Wang, D., Zhang, X., Huang, X.-Y., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad1a4c · Cited by 58
A lab-based test of the gravitational redshift with a miniature clock network
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023) · Nature Communications · doi:10.1038/s41467-023-40629-8 · Cited by 47
Metadata
- Authors
- Ohmae, N., Takamoto, M., Takahashi, Y., Kokubun, M., Araki, K., Hinton, A., Ushijima, I., Muramatsu, T., Furumiya, T., Sakai, Y., Moriya, N., Kamiya, N., Fujii, K., Muramatsu, R., Shiimado, T., & Katori, H.
- Affiliations
- Fukuoka University (JP)
- RIKEN (JP)
- Japan Aerospace Exploration Agency (JP)
- RIKEN Center for Advanced Photonics (JP)
- Shimadzu (Japan) (JP)
- Equos Research Co., Ltd. 1‐18‐13 Sotokanda Chiyoda‐ku Tokyo 101‐0021 Japan
- Corresponding author
- Ohmae, Noriaki
- Venue
- Advanced Quantum Technologies
- Publisher
- Wiley
- Published
- 2021-05-31
- Volume
- 4
- Issue
- 8
- ISSN
- 2511-9044 (ISSN-L)
- OpenAlex
- W3171777338
- Cited by
- 79
- References
- 43
- Citations by year
- 2026: 7 · 2025: 17 · 2024: 24 · 2023: 16 · 2022: 14 · 2021: 1
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Advanced Quantum Technologies (publishedVersion, cc-by-nc-nd)
- Funders
- Japan Society for the Promotion of Science (JP16H06284)
- Japan Science and Technology Agency (JPMJMI18A1)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- strontium optical lattice clock, external cavity diode laser, fractional frequency uncertainty, acceleration tolerance, optical misalignment, height difference measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.