Transportable Strontium Optical Lattice Clocks Operated Outside Laboratory at the Level of 10 −18 Uncertainty
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Transportable strontium optical lattice clocks are developed with a fractional uncertainty of 5.5 × 10 −18 for applications outside laboratories. A single clock consists of a spectroscopy chamber and two laser boxes, where all lasers are based on external cavity diode lasers with an adjustment‐free, laser‐welded output coupler. When this system is transported from the laboratory at RIKEN to a broadcasting tower, the instruments experience acceleration change of 4 G at maximum. However, no serious optical misalignments are found. The demonstration opens up field applications of optical atomic clocks resolving a centimeter height difference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Today, several groups operate transportable optical clocks [16, 17, 25-31].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Self-citationTest of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Self-citationGeodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Research works printed but not linked: 4
- C W Chou, D B Hume, J C J Koelemeij, D J Wineland, T Rosenband, Phys. Rev. Lett. 10470802C. W. Chou, D. B. Hume, J. C. J. Koelemeij, D. J. Wineland, T. Rosen- band, Phys. Rev. Lett. 2020, 104, 070802.
- Adv. Quantum Technol. 20212100015Adv. Quantum Technol. 2021, 4, 2100015
- D B Hassan, D Hume, C J Kedar, I Kennedy, A Khader, D R Koepke, H Leibrandt, A D Leopardi, W F Ludlow, W R Mcgrew, N R Milner, D Newbury, E Nicolodi, T E Oelker, J M Parker, S Robinson, S A Romisch, J A Schäffer, L C Sherman, Sinclair, Nature. 564Hassan, D. B. Hume, D. Kedar, C. J. Kennedy, I. Khader, A. Koepke, D. R. Leibrandt, H. Leopardi, A. D. Ludlow, W. F. McGrew, W. R. Milner, N. R. Newbury, D. Nicolodi, E. Oelker, T. E. Parker, J. M. Robinson, S. Romisch, S. A. Schäffer, J. A. Sherman, L. C. Sinclair, et al., Nature 2021, 591, 564.
- H S Bayne, P Margolis, Gill, Phys. Rev. Lett. 221102Bayne, H. S. Margolis, P. Gill, Phys. Rev. Lett. 2017, 118, 221102.
Cited by
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 211
“An accuracy ranging from 10 − 15 down to parts in 10 18 has been reported for several 87 Sr TOCs [86–88].”
BackgroundKobayashi, T., Takamizawa, A., Akamatsu, D., Kawasaki, A., Nishiyama, A., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Tanabe, T., et al. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.241301 · Cited by 66
Coherence limits in lattice atom interferometry at the one-minute scale
Panda, C. D., Tao, M., Egelhoff, J., Ceja, M., Xu, V., & Müller, H. (2024) · Nature Physics · doi:10.1038/s41567-024-02518-9 · Cited by 61
“For example, optical lattice clocks with atoms trapped for 15 s have enabled 2–3 orders of magnitude gains 1,2 in precision relative to atomic fountain clocks.”
A strontium lattice clock with both stability and uncertainty below 5 × 10 − 18
Li, J., Cui, X.-Y., Jia, Z.-P., Kong, D.-Q., Yu, H.-W., Zhu, X.-Q., Liu, X., Wang, D., Zhang, X., Huang, X.-Y., et al. (2024) · Metrologia · doi:10.1088/1681-7575/ad1a4c · Cited by 58
A lab-based test of the gravitational redshift with a miniature clock network
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023) · Nature Communications · doi:10.1038/s41467-023-40629-8 · Cited by 47
Metadata
- Authors
- Ohmae, N., Takamoto, M., Takahashi, Y., Kokubun, M., Araki, K., Hinton, A., Ushijima, I., Muramatsu, T., Furumiya, T., Sakai, Y., Moriya, N., Kamiya, N., Fujii, K., Muramatsu, R., Shiimado, T., & Katori, H.
- Affiliations
- Fukuoka University (JP)
- RIKEN (JP)
- Japan Aerospace Exploration Agency (JP)
- RIKEN Center for Advanced Photonics (JP)
- Shimadzu (Japan) (JP)
- Equos Research Co., Ltd. 1‐18‐13 Sotokanda Chiyoda‐ku Tokyo 101‐0021 Japan
- Corresponding author
- Ohmae, Noriaki
- Venue
- Advanced Quantum Technologies
- Publisher
- Wiley
- Published
- 2021-05-31
- Volume
- 4
- Issue
- 8
- ISSN
- 2511-9044 (ISSN-L)
- OpenAlex
- W3171777338
- Cited by
- 79
- References
- 43
- Citations by year
- 2026: 7 · 2025: 17 · 2024: 24 · 2023: 16 · 2022: 14 · 2021: 1
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Advanced Quantum Technologies (publishedVersion, cc-by-nc-nd)
- Funders
- Japan Society for the Promotion of Science (JP16H06284)
- Japan Science and Technology Agency (JPMJMI18A1)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- strontium optical lattice clock, external cavity diode laser, fractional frequency uncertainty, acceleration tolerance, optical misalignment, height difference measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.