The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Conformational changes in proteins probed by hydrogen‐exchange electrospray‐ionization mass spectrometry
Abstract
Hydrogen‐exchange electrospray‐ionization mass spectrometry is demonstrated to be an effective new method for probing conformational changes of proteins in solutions. The method is based on the mass spectrometric measurement of the extent of hydrogen/deuterium exchange that occurs in different protein conformers over defined periods of time. Results are presented in which hydrogen‐exchange electrospray‐ionization mass spectrometry is used to probe conformational changes in bovine ubiquitin induced by the addition of methanol to aqueous acidic solutions of the protein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NMR with Proteins and Nucleic Acids
Wüthrich, K. (1986) · Europhysics News · doi:10.1051/epn/19861701011 · Cited by 7,989
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
NMR of Proteins and Nucleic Acids
(2006) · Nuclear Magnetic Resonance · doi:10.1039/9781847555236-00336 · Cited by 5,863
Structure of ubiquitin refined at 1.8 Å resolution
Vijay-kumar, S., Bugg, C. E., & Cook, W. J. (1987) · Journal of Molecular Biology · doi:10.1016/0022-2836(87)90679-6 · Cited by 1,742
Hydrogen exchange and structural dynamics of proteins and nucleic acids
Englander, S. W., & Kallenbach, N. R. (1983) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500005217 · Cited by 1,356
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Roder, H., Elöve, G. A., & Englander, S. W. (1988) · Nature · doi:10.1038/335700a0 · Cited by 813
Structural Characterization of a Partly Folded Apomyoglobin Intermediate
Hughson, F. M., Wright, P. E., & Baldwin, R. L. (1990) · Science · doi:10.1126/science.2218495 · Cited by 705
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 646
Self-citationCovey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Cited by
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Hydrogen exchange mass spectrometry for the analysis of protein dynamics
Wales, T. E., & Engen, J. R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20064 · Cited by 862
Hydrogen exchange mass spectrometry for studying protein structure and dynamics
Konermann, L., Pan, J., & Liu, Y.-H. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00113a · Cited by 838
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Detection of Transient Protein Folding Populations by Mass Spectrometry
Miranker, A., Robinson, C. V., Radford, S. E., Aplin, R. T., & Dobson, C. M. (1993) · Science · doi:10.1126/science.8235611 · Cited by 546
Fernandez de la Mora, J. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00601-7 · Cited by 528
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
Effect of eluent on the ionization process in liquid chromatography–mass spectrometry
Kostiainen, R., & Kauppila, T. J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.095 · Cited by 402
Weighing Naked Proteins: Practical, High-Accuracy Mass Measurement of Peptides and Proteins
Chait, B. T., & Kent, S. B. H. (1992) · Science · doi:10.1126/science.1411504 · Cited by 393
Self-citationGas-Phase Conformation of Biological Molecules: Bradykinin
Wyttenbach, T., von Helden, G., & Bowers, M. T. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9535928 · Cited by 384
Mechanisms and uses of hydrogen exchange
Englander, S. W., Sosnick, T. R., Englander, J. J., & Mayne, L. (1996) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(96)80090-x · Cited by 383
Protein Analysis by Hydrogen Exchange Mass Spectrometry
Hoofnagle, A. N., Resing, K. A., & Ahn, N. G. (2003) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.32.110601.142417 · Cited by 381
Houde, D., Berkowitz, S. A., & Engen, J. R. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22432 · Cited by 375
Analysis of Protein Conformation and Dynamics by Hydrogen/Deuterium Exchange MS
Engen, J. R. (2009) · Analytical Chemistry · doi:10.1021/ac901154s · Cited by 369
von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · Science · doi:10.1126/science.267.5203.1483 · Cited by 363
Przybylski, M., & Glocker, M. O. (1996) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199608061 · Cited by 351
Wyttenbach, T., & Bowers, M. T. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp206867a · Cited by 346
Coexisting stable conformations of gaseous protein ions.
Suckau, D., Shi, Y., Beu, S. C., Senko, M. W., Quinn, J. P., Wampler, F. M., & McLafferty, F. W. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.3.790 · Cited by 345
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Studies of biomolecular conformations and conformational dynamics by mass spectrometry
Kaltashov, I. A., & Eyles, S. J. (2002) · Mass Spectrometry Reviews · doi:10.1002/mas.10017 · Cited by 270
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Differential hydrogen/deuterium exchange mass spectrometry analysis of protein–ligand interactions
Chalmers, M. J., Busby, S. A., Pascal, B. D., West, G. M., & Griffin, P. R. (2011) · Expert Review of Proteomics · doi:10.1586/epr.10.109 · Cited by 252
Ion/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins
Stephenson, J. L., & McLuckey, S. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9611755 · Cited by 215
Wei, H., Mo, J., Tao, L., Russell, R. J., Tymiak, A. A., Chen, G., Iacob, R. E., & Engen, J. R. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.07.019 · Cited by 208
Surfactant effects on protein structure examined by electrospray ionization mass spectrometry
Loo, R. R. O., Dales, N., & Andrews, P. C. (1994) · Protein Science · doi:10.1002/pro.5560031109 · Cited by 184
The evolving contribution of mass spectrometry to integrative structural biology
Faini, M., Stengel, F., & Aebersold, R. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1382-4 · Cited by 44
Status of, and developments in, mass spectrometry of peptides and proteins
Roepstorff, P., & Richter, W. J. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)85085-e · Cited by 15
Metadata
- Authors
- Katta, V., Chait, B. T., & Carr, S.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 1991-04
- Volume
- 5
- Issue
- 4
- Pages
- 214-217
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2115463031
- Cited by
- 453
- References
- 17
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.