A Stretchable and Flexible Cardiac Tissue–Electronics Hybrid Enabling Multiple Drug Release, Sensing, and Stimulation
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Replacement of the damaged scar tissue created by a myocardial infarction is the goal of cardiac tissue engineering. However, once the implanted tissue is in place, monitoring its function is difficult and involves indirect methods, while intervention necessarily requires an invasive procedure and available medical attention. To overcome this, methods of integrating electronic components into engineered tissues have been recently presented. These allow for remote monitoring of tissue function as well as intervention through stimulation and controlled drug release. Here, an improved hybrid microelectronic tissue construct capable of withstanding the dynamic environment of the beating heart without compromising electronic or mechanical functionality is reported. While the reported system is enabled to sense the function of the engineered tissue and provide stimulation for pacing, an electroactive polymer on the electronics enables it to release multiple drugs in parallel. It is envisioned that the integration of microelectronic devices into engineered tissues will provide a better way to monitor patient health from afar, as well as provide facile, more exact methods to control the healing process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Self-citationConformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Tissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Self-citationU.S. Preventive Services Task Force* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-150-6-200903170-00008 · Cited by 533
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705509114 · Cited by 227
Three-dimensional transmural organization of perimysial collagen in the heart
Pope, A. J., Sands, G. B., Smaill, B. H., & LeGrice, I. J. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00484.2008 · Cited by 205
Personalized Hydrogels for Engineering Diverse Fully Autologous Tissue Implants
Edri, R., Gal, I., Noor, N., Harel, T., Fleischer, S., Adadi, N., Green, O., Shabat, D., Heller, L., Shapira, A., et al. (2019) · Advanced Materials · doi:10.1002/adma.201803895 · Cited by 128
Self-citationComposite biomaterial scaffolds for cardiac tissue engineering
Shapira, A., Feiner, R., & Dvir, T. (2016) · International Materials Reviews · doi:10.1179/1743280415y.0000000012 · Cited by 114
Self-citationWendel, J. S., Ye, L., Tao, R., Zhang, J., Zhang, J., Kamp, T. J., & Tranquillo, R. T. (2015) · Stem Cells Translational Medicine · doi:10.5966/sctm.2015-0044 · Cited by 105
Syringe-injectable electronics with a plug-and-play input/output interface.
Schuhmann, T. G., Yao, J., Hong, G., Fu, T.-M., & Lieber, C. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b03081 · Cited by 63
Cited by
Electrospinning for drug delivery applications: A review
Luraghi, A., Peri, F., & Moroni, L. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.03.033 · Cited by 746
Advanced Hydrogels as Wound Dressings
Tavakoli, S., & Klar, A. S. (2020) · Biomolecules · doi:10.3390/biom10081169 · Cited by 544
Pang, Q., Lou, D., Li, S., Wang, G., Qiao, B., Dong, S., Ma, L., Gao, C., & Wu, Z. (2020) · Advanced Science · doi:10.1002/advs.201902673 · Cited by 490
Flexible Electronics: Status, Challenges and Opportunities
Corzo, D., Tostado-Blázquez, G., & Baran, D. (2020) · Frontiers in Electronics · doi:10.3389/felec.2020.594003 · Cited by 391
Abdulhussain, R., Adebisi, A., Conway, B. R., & Asare-Addo, K. (2023) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2023.105156 · Cited by 289
Metadata
- Authors
- Feiner, R., Wertheim, L., Gazit, D., Kalish, O., Mishal, G., Shapira, A., & Dvir, T.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2019-03-05
- Volume
- 15
- Issue
- 14
- Pages
- e1805526-e1805526
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2921538537
- Cited by
- 70
- References
- 15
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.