A Taxonomy of Attacks on the DNP3 Protocol
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attack taxonomies for the Modbus protocols
Huitsing, P., Chandia, R., Papa, M., & Shenoi, S. (2008) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2008.08.003 · Cited by 249
Self-citation
Cited by
Cyber–Physical System Security for the Electric Power Grid
Sridhar, S., Hahn, A., & Govindarasu, M. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165269 · Cited by 1,208
Cyber-Physical Systems Security—A Survey
Humayed, A., Lin, J., Li, F., & Luo, B. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2703172 · Cited by 1,185
A Survey of Random Forest Based Methods for Intrusion Detection Systems
Resende, P. A. A., & Drummond, A. C. (2019) · ACM Computing Surveys · doi:10.1145/3178582 · Cited by 368
A survey of cyber security management in industrial control systems
Knowles, W., Prince, D., Hutchison, D., Disso, J. F. P., & Jones, K. (2015) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2015.02.002 · Cited by 344
A Survey on SCADA Systems: Secure Protocols, Incidents, Threats and Tactics
Pliatsios, D., Sarigiannidis, P., Lagkas, T., & Sarigiannidis, A. G. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.2987688 · Cited by 320
“The authors in [61] and [62] provide a taxonomy of attacks on the DNP3 protocol: • Reset Function Attack: The attacker sends a message that causes the device to restart, making it unavailable for a period of time.”
BackgroundCybersecurity of industrial cyber-physical systems: A review
Kayan, H., Nunes, M., Rana, O., Burnap, P., & Perera, C. (2022) · ACM Computing Surveys · doi:10.1145/3510410 · Cited by 261
A Multidimensional Critical State Analysis for Detecting Intrusions in SCADA Systems
Carcano, A., Coletta, A., Guglielmi, M., Masera, M., Nai Fovino, I., & Trombetta, A. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2010.2099234 · Cited by 259
“For that reason, it can be considered as an additional feature, which can highly contribute to increase the detection accuracy of existing IDS.”
BackgroundAttack detection and identification for automatic generation control systems
Ameli, A., Hooshyar, A., El-Saadany, E. F., & Youssef, A. M. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2810161 · Cited by 222
Review of cybersecurity issues in industrial critical infrastructure: manufacturing in perspective
Ani, U. P. D., He, H. (., & Tiwari, A. (2017) · Journal of Cyber Security Technology · doi:10.1080/23742917.2016.1252211 · Cited by 209
Zografopoulos, I., Hatziargyriou, N. D., & Konstantinou, C. (2023) · IEEE Systems Journal · doi:10.1109/jsyst.2023.3305757 · Cited by 173
“For instance, the authors in [30], provide a comprehensive attack taxonomy for DNP3 and”
BackgroundInfluentialKoay, A. M. Y., Ko, R. K. L., Hettema, H., & Radke, K. (2023) · Journal of Intelligent Information Systems · doi:10.1007/s10844-022-00753-1 · Cited by 131
“In the default configuration it contains no authentication or encryption of the payload (East et al., 2009).”
BackgroundWind farm security: attack surface, targets, scenarios and mitigation
Staggs, J., Ferlemann, D., & Shenoi, S. (2017) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2017.03.001 · Cited by 92
Self-citationGenge, B., Siaterlis, C., Nai Fovino, I., & Masera, M. (2012) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2012.06.015 · Cited by 82
“Nowadays CIs, or more specifically Networked Industrial Control Systems (NICS), are exposed to significant cyber-threats; a fact that has been highlighted by many studies on the security of Supervisory Control And Data Acquisition (SCADA) systems [1, 2, 3].”
BackgroundSecuring DNP3 broadcast communications in SCADA systems
Amoah, R., Camtepe, S., & Foo, E. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2587883 · Cited by 72
Hayes, G., & El-Khatib, K. (2013) · 2013 Third International Conference on Communications and Information Technology (ICCIT) · doi:10.1109/iccitechnology.2013.6579545 · Cited by 65
Sundararajan, A., Chavan, A., Saleem, D., & Sarwat, A. I. (2018) · Energies · doi:10.3390/en11092360 · Cited by 57
“19 and 22, the C12 security requirements apply [55].”
BackgroundAn event buffer flooding attack in DNP3 controlled SCADA systems
Jin, D., Nicol, D. M., & Yan, G. (2011) · Proceedings of the 2011 Winter Simulation Conference (WSC) · doi:10.1109/wsc.2011.6147969 · Cited by 56
SCADA security: a review and enhancement for DNP3 based systems
Jain, P., & Tripathi, P. (2013) · CSI Transactions on ICT · doi:10.1007/s40012-013-0024-2 · Cited by 30
Secure authentication in the grid: A formal analysis of DNP3 SAv5
Cremers, C., Dehnel-Wild, M., & Milner, K. (2019) · Journal of Computer Security · doi:10.3233/jcs-181139 · Cited by 27
“2009 provide an interesting and thorough taxonomy of the different types of attack against DNP3 in [13], but as this paper was published before SAv5 was standardised, it does not consider Secure Authentication.”
Background
Metadata
- Authors
- East, S., Butts, J., Papa, M., & Shenoi, S.
- Venue
- IFIP Advances in Information and Communication Technology
- Publisher
- Springer Berlin Heidelberg
- Published
- 2009
- Pages
- 67-81
- ISSN
- 1868-422X (ISSN-L)
- 1868-4238
- OpenAlex
- W1546161534
- Cited by
- 193
- References
- 1
- FWCI
- 9.51
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.