A single-blind, randomised, crossover study to reduce hypoglycaemia risk during postprandial exercise with closed-loop insulin delivery in adults with type 1 diabetes: announced (with or without bolus reduction) vs unannounced exercise strategies
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Aims/hypothesis For individuals living with type 1 diabetes, closed-loop insulin delivery improves glycaemic control. Nonetheless, maintenance of glycaemic control during exercise while a prandial insulin bolus remains active is a challenge even to closed-loop systems. We investigated the effect of exercise announcement on the efficacy of a closed-loop system, to reduce hypoglycaemia during postprandial exercise.Methods A single-blind randomised, crossover open-label trial was carried out to compare three strategies applied to a closed-loop system at mealtime in preparation for exercise taken 90 min after eating at a research testing centre: (1) announced exercise to the closed-loop system (increases target glucose levels) in addition to a 33% reduction in meal bolus (A-RB); (2) announced exercise to the closed-loop system and a full meal bolus (A-FB); (3) unannounced exercise and a full meal bolus (U-FB). Participants performed 60 min of exercise at 60% [Formula: see text] 90 min after eating breakfast. The investigators were not blinded to the interventions. However, the participants were blinded to the sensor glucose readings and to the insulin infusion rates throughout the intervention visits.Results The trial was completed by 37 adults with type 1 diabetes, all using insulin pumps: mean±SD, 40.0 ± 15.0 years of age, HbA 1c 57.1 ± 10.8 mmol/mol (7.3 ± 1.0%). Reported results were based on plasma glucose values. During exercise and the following 1 h recovery period, time spent in hypoglycaemia (<3.9 mmol/l; primary outcome) was reduced with A-RB (mean ± SD; 2.0 ± 6.2%) and A-FB (7.0 ± 12.6%) vs U-FB (13.0 ± 19.0%; p < 0.0001 and p = 0.005, respectively). During exercise, A-RB had the least drop in plasma glucose levels: A-RB -0.3 ± 2.8 mmol/l, A-FB -2.6 ± 2.9 mmol/l vs U-FB -2.4 ± 2.7 mmol/l (p < 0.0001 and p = 0.5, respectively). Comparison of A-RB vs U-FB revealed a decrease in the time spent in target (3.9-10 mmol/l) by 12.7% (p = 0.05) and an increase in the time spent in hyperglycaemia (>10 mmol/l) by 21% (p = 0.001). No side effects were reported during the applied strategies.Conclusions/interpretation Combining postprandial exercise announcement, which increases closed-loop system glucose target levels, with a 33% meal bolus reduction significantly reduced time spent in hypoglycaemia compared with the other two strategies, yet at the expense of more time spent in hyperglycaemia.Trial registration ClinicalTrials.gov NCT0285530 FUNDING: JDRF (2-SRA-2016-210-A-N), the Canadian Institutes of Health Research (354024) and the Fondation J.-A. DeSève chair held by RR-L.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exercise management in type 1 diabetes: a consensus statement
Riddell, M. C., Gallen, I. W., Smart, C. E., Taplin, C. E., Adolfsson, P., Lumb, A. N., Kowalski, A., Rabasa-Lhoret, R., McCrimmon, R. J., Hume, C., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30014-1 · Cited by 903
Self-citationValidation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
Rabasa-Lhoret, R., Bourque, J., Ducros, F., & Chiasson, J.-L. (2001) · Diabetes Care · doi:10.2337/diacare.24.4.625 · Cited by 301
Self-citationAccurate prediction of &OV0312;O2max in cycle ergometry
STORER, T. W., DAVIS, J. A., & CAIOZZO, V. J. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199010000-00024 · Cited by 216
Outcome measures for artificial pancreas clinical trials: a consensus report
Maahs, D. M., Buckingham, B. A., Castle, J. R., Cinar, A., Damiano, E. R., Dassau, E., DeVries, J. H., Doyle, F. J., Griffen, S. C., Haidar, A., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2716 · Cited by 211
Breton, M. D., Cherñavvsky, D. R., Forlenza, G. P., DeBoer, M. D., Robic, J., Wadwa, R. P., Messer, L. H., Kovatchev, B. P., & Maahs, D. M. (2017) · Diabetes Care · doi:10.2337/dc17-0883 · Cited by 179
Haidar, A., Legault, L., Dallaire, M., Alkhateeb, A., Coriati, A., Messier, V., Cheng, P., Millette, M., Boulet, B., & Rabasa-Lhoret, R. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.121265 · Cited by 167
Self-citationCastle, J. R., El Youssef, J., Wilson, L. M., Reddy, R., Resalat, N., Branigan, D., Ramsey, K., Leitschuh, J., Rajhbeharrysingh, U., Senf, B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0228 · Cited by 152
Haidar, A., Tsoukas, M. A., Bernier-Twardy, S., Yale, J.-F., Rutkowski, J., Bossy, A., Pytka, E., El Fathi, A., Strauss, N., & Legault, L. (2020) · Diabetes Care · doi:10.2337/dc19-1922 · Cited by 138
Self-citationTaleb, N., Emami, A., Suppère, C., Messier, V., Legault, L., Ladouceur, M., Chiasson, J., Haidar, A., & RABASA-LHORET, R. P. R. (2016) · Diabetologia · doi:10.1007/s00125-016-4107-0 · Cited by 133
Self-citationHaidar, A., Legault, L., Matteau‐Pelletier, L., Messier, V., Dallaire, M., Ladouceur, M., & RABASA-LHORET, R. P. R. (2015) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(15)00141-2 · Cited by 129
Self-citationJacobs, P. G., El Youssef, J., Reddy, R., Resalat, N., Branigan, D., Condon, J., Preiser, N., Ramsey, K., Jones, M., Edwards, C., et al. (2016) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12707 · Cited by 116
Gingras, V., Taleb, N., Roy‐Fleming, A., Legault, L., & Rabasa‐Lhoret, R. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13052 · Cited by 113 · cited 1×
“Postprandial exercise combines multiple challenges for a closed-loop system [9, 29, 30]: the difficulty to control postprandial glucose excursions [12, 30] and the inability to reduce circulating insulin levels secondary to insulin meal bolus during exercise-induced hypoglycaemia.”
BackgroundSelf-citationJacobs, P. G., Resalat, N., El Youssef, J., Reddy, R., Branigan, D., Preiser, N., Condon, J., & Castle, J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815609371 · Cited by 105
Sherr, J. L., Patel, N. S., Michaud, C. I., Palau-Collazo, M. M., Van Name, M. A., Tamborlane, W. V., Cengiz, E., Carria, L. R., Tichy, E. M., & Weinzimer, S. A. (2016) · Diabetes Care · doi:10.2337/dc16-0089 · Cited by 99
Insulin pump basal adjustment for exercise in type 1 diabetes: a randomised crossover study
McAuley, S. A., Horsburgh, J. C., Ward, G. M., Gerche, A. L., Gooley, J. L., Jenkins, A. J., MacIsaac, R. J., & O'Neal, D. N. (2016) · Diabetologia · doi:10.1007/s00125-016-3981-9 · Cited by 90
Zaharieva, D. P., MCGAUGH, S. M., Pooni, R., Vienneau, T. E., Ly, T. T., & Riddell, M. C. (2019) · Diabetes Care · doi:10.2337/dc18-2204 · Cited by 90
Single- and Dual-Hormone Artificial Pancreas for Overnight Glucose Control in Type 1 Diabetes
Haidar, A., Rabasa-Lhoret, R., Legault, L., Lovblom, L. E., Rakheja, R., Messier, V., D'Aoust, É., Falappa, C. M., Justice, T., Orszag, A., et al. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-3003 · Cited by 89
Self-citationFranc, S., Daoudi, A., Pochat, A., Petit, M. ‐., Randazzo, C., Petit, C., Duclos, M., Penfornis, A., Pussard, E., Not, D., et al. (2015) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12552 · Cited by 87
Dovc, K., Macedoni, M., Bratina, N., Lepej, D., Nimri, R., Atlas, E., Muller, I., Kordonouri, O., Biester, T., Danne, T., et al. (2017) · Diabetologia · doi:10.1007/s00125-017-4395-z · Cited by 85
Houlden, R. L. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.001 · Cited by 81
Multivariable Artificial Pancreas for Various Exercise Types and Intensities
Turksoy, K., Hajizadeh, I., Hobbs, N., Kilkus, J. M., Littlejohn, E., Samadi, S., Feng, J., Sevil, M., Lazaro, C., Ritthaler, J., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0072 · Cited by 77
Huyett, L. M., Ly, T. T., Forlenza, G. P., Reuschel-DiVirgilio, S., Messer, L. H., Wadwa, R. P., Gondhalekar, R., Doyle, F. J., Pinsker, J. E., Maahs, D. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0399 · Cited by 64
Zaharieva, D., Yavelberg, L., Jamnik, V., Cinar, A., Turksoy, K., & Riddell, M. C. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0010 · Cited by 61
Moser, O., Mader, J., Tschakert, G., Mueller, A., Groeschl, W., Pieber, T., Koehler, G., Messerschmidt, J., & Hofmann, P. (2016) · Nutrients · doi:10.3390/nu8080489 · Cited by 60
Tagougui, S., Taleb, N., Molvau, J., Nguyen, É., Raffray, M., & RABASA-LHORET, R. P. R. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819869310 · Cited by 58
Self-citationTagougui, S., Taleb, N., & Rabasa-Lhoret, R. (2019) · Frontiers in Endocrinology · doi:10.3389/fendo.2018.00818 · Cited by 56
Self-citationSchiavon, M., Man, C. D., Kudva, Y. C., Basu, A., & Cobelli, C. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700606 · Cited by 52
Gingras, V., Bonato, L., Messier, V., Roy‐Fleming, A., Smaoui, M. R., Ladouceur, M., & RABASA-LHORET, R. P. R. (2018) · Diabetes Obesity and Metabolism · doi:10.1111/dom.13445 · Cited by 45 · cited 1×
“Postprandial exercise combines multiple challenges for a closed-loop system [9, 29, 30]: the difficulty to control postprandial glucose excursions [12, 30] and the inability to reduce circulating insulin levels secondary to insulin meal bolus during exercise-induced hypoglycaemia.”
BackgroundSelf-citationRoy‐Fleming, A., Taleb, N., Messier, V., Suppère, C., Cameli, C., Elbekri, S., Smaoui, M. R., Ladouceur, M., Legault, L., & RABASA-LHORET, R. P. R. (2018) · Diabetes & Metabolism · doi:10.1016/j.diabet.2018.08.002 · Cited by 41
Self-citationPinsker, J. E., Laguna Sanz, A. J., Lee, J. B., Church, M. M., Andre, C., Lindsey, L. E., Doyle, F. J., & Dassau, E. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0031 · Cited by 39
Use of Wearable Sensors and Biometric Variables in an Artificial Pancreas System
Turksoy, K., Monforti, C., Park, M., Griffith, G., Quinn, L., & Çınar, A. (2017) · Sensors · doi:10.3390/s17030532 · Cited by 36
Patel, N. S., Van Name, M. A., Cengiz, E., Carria, L. R., Tichy, E. M., Weyman, K., Weinzimer, S. A., Tamborlane, W. V., & Sherr, J. L. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0311 · Cited by 34
Larose, S., RABASA-LHORET, R. P. R., Roy‐Fleming, A., Suppère, C., Tagougui, S., Messier, V., & Taleb, N. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0400 · Cited by 31
Self-citationBertachi, A. H., Beneyto, A., Ramkissoon, C. M., & Vehí, J. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0392 · Cited by 23
Modeling the acute effects of exercise on insulin kinetics in type 1 diabetes
Frank, S., Jbaily, A., Hinshaw, L., Basu, R., Basu, A., & Szeri, A. J. (2018) · Journal of Pharmacokinetics and Pharmacodynamics · doi:10.1007/s10928-018-9611-z · Cited by 22
Single-Hormone Artificial Pancreas Use in Diabetes: Clinical Efficacy and Remaining Challenges
Taleb, N., Tagougui, S., & RABASA-LHORET, R. P. R. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0094 · Cited by 11
Self-citation
Research works printed but not linked: 23
- 1. Miller KM, Foster NC, Beck RW, et al. Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry. Diabetes Care 2015; 38 : 971-78.
- 2. Bergenstal RM, Garg S, Weinzimer SA, et al. Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes. JAMA 2016; 316 : 14078.
- 3. Garg SK, Weinzimer SA, Tamborlane WV, et al. Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes. Diabetes Technol Ther 2017; 19 : 155-163.
- 4. Weisman A, Bai JW, Cardinez M, et al. Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials. Lancet Diabetes Endocrinol 2017; 5 : 501-12.
- 5. Bekiari E, Kitsios K, Thabit H, et al. Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis. BMJ 2018; 361 : k1310.
- 6. Nimri R, Muller I, Atlas E, et al. MD-Logic Overnight Control for 6 Weeks of Home Use in Patients With Type 1 Diabetes: Randomized Crossover Trial. Diabetes Care 2014; 37 : 3025-3032.
- 7. Kropff J, Del Favero S, Place J, et al; AP@home consortium. 2 month evening and night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: a randomised crossover trial. Lancet Diabetes Endocrinol 2015; 3 : 939-47.
- 8. Thabit H, Tauschmann M, Allen JM, et al; APCam Consortium and AP@home Consortium. Home use of an artificial beta cell in type 1 diabetes. N Engl J Med 2015; 373 : 2129-40.
- 9. Bally L, Thabit H, Kojzar H, et al. Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in freeliving adults with well controlled type 1 diabetes: an open-label, randomised, crossover study. Lancet Diabetes Endocrinol 2017; 5 : 261-70.
- 10. Tauschmann M, Thabit H, Bally L, et al; APCam11 Consortium. Closedloop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial. Lancet 2018; 392 : 1321-9.
- 11. Gold AE, MacLeod KM, Frier BM. Frequency of severe hypoglycemia in patients with type I diabetes with impaired awareness of hypoglycemia. Diabetes Care 1994; 17 : 697-703.
- 12. Benhamou PY, Huneker E, Franc S, Doron M, Charpentier G, the Diabeloop Consortium. Customization of home closed-loop insulin delivery in adult patients with type 1 diabetes, assisted with structured remote monitoring: the pilot WP7 Diabeloop study. Acta Diabetol 2018; 55 : 549-556.
- 19. Messer LH, Forlenza GP, Sherr JL, et al. Optimizing hybrid closed-loop therapy in adolescents and emerging adults using the MiniMed 670G System. Diabetes Care 2018; 41 : 789-96.
- 20. Charpentier G, Benhamou PY, Dardari D, et al. The Diabeo software enabling individualized insulin dose adjustments combined with telemedicine support improves HbA1c in poorly controlled type 1 diabetic patients: a 6month, randomized, open-label, parallel-group, multicenter trial (TeleDiab 1 Study). Diabetes Care 2011; 34 : 533-9.
- 21. Dassau E, Pinsker JE, Kudva YC, et al. Twelve-Week 24/7 Ambulatory - Artificial Pancreas With Weekly Adaptation of Insulin Delivery Settings: Effect on Hemoglobin A1c and Hypoglycemia. Diabetes Care 2017; 40 : 1719-1726.
- 22. Burckhardt MA, Roberts A, Smith GJ, Abraham MB, Davis EA, Jones TW. The Use of Continuous Glucose Monitoring With Remote Monitoring Improves Psychosocial Measures in Parents of Children With Type 1 Diabetes: A Randomized Crossover Trial. Diabetes Care 2018; 41 : 2641-2643.
- 23. Mauras N, Beck R, Xing D, et al.; Diabetes Research in Children Network (DirecNet) Study Group. A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to 10 years. Diabetes Care 2012; 35 : 204-210.
- 24. Quintal A, Messier V, Rabasa-Lhoret R, Racine E. A critical review and analysis of ethical issues associated with the artificial pancreas. Diabetes Metab 2019; 45 : 1-10.
- 25. Forlenza GP, Deshpande S, Ly TT, et al. Application of Zone Model Predictive Control Artificial Pancreas During Extended Use Of Infusion Set and Sensor: A Randomized Crossover-Controlled Home-Use Trial. Diabetes Care 2017; 40 : 1096-1102.
- 27. Lu J, Ma X, Zhou J, et al. Association of Time in Range, as Assessed by Continuous Glucose Monitoring, With Diabetic Retinopathy in Type 2 Diabetes. Diabetes Care 2018; 41 : 2370-2376.
- 28. Toward Development of Psychosocial Measures for Automated Insulin Delivery. Weissberg-Benchell J, Hood K, Laffel L, et al. J Diabetes Sci Technol 2016; 10 : 799-801. <!-- image --> <!-- image --> Table 1. Characteristics of Patients at Baseline | | modified Intention-To-Treat population (n=63) | |------------------------------|-------------------------------------------------| | Gender | | | Female | 39 (62%) | | Male | 24 (38%) | | Age (years) | 48·2 (13·4) | | Body weight (kg) | 70·8 (11·0) | | BMI (kg/m 2 ) | 24·8 (3·5) | | Duration of diabetes (years) | 28·0 (13·6) | | HbA1c (%) | 7·6 (0·9) | | HbA1c (mmol/mol) | 59·4 (9·8) | | Total Daily Insulin (U/d) | 36·3 (8·9) | Data are mean (SD) or n (%). Table 2. 24-h glucose control during closed-loop and control periods based on sensor glucose measurements (modified intention-to-treat analysis) | | Closed-loop period (n=63) | Control period (n=63) | Paired difference (CI 95%) * | p value | p value ** | |------------------------------------------------------------|------------------------------------------------------------|------------------------------------------------------------|------------------------------------------------------------|------------------------------------------------------------|------------------------------------------------------------| | Day and night (24h) | Day and night (24h) | Day and night (24h) | Day and night (24h) | Day and night (24h) | Day and night (24h) | | Proportion of time with glucose concentration in range (%) | Proportion of time with glucose concentration in range (%) | Proportion of time with glucose concentration in range (%) | Proportion of time with glucose concentration in range (%) | Proportion of time with glucose concentration in range (%) | Proportion of time with glucose concentration in range (%) | | 3·9 - 10·0 mmol/L † | 68·5 (1·2) | 59·4 (1·3) | 9·2 (6·4 to 11·9) | <0·0001 | <0·0001 | | 4·4 - 7·8 mmol/L | 39·3 (1·0) | 33·5 (1·0) | 5·8 (3·7 to 7·9) | <0·0001 | <0·0001 | | > 10·0 mmol/L | 29·5 (1·3) | 36·3 (1·3) | -6·8 (-9·7 to -3·9) | <0·0001 | <0·001 | | > 13·9 mmol/L | 7·4 (0·8) | 11·7 (0·8) | -4·3 (-6·2 to -2·4) | <0·0001 | <0·001 | | > 16·7 mmol/L | 2·4 (0·4) | 4·3 (0·4) | -2·0 (-3·0 to -1·0) | <0·001 | <0·0001 | | < 3·9 mmol/L | 2·0 (0·3) | 4·3 (0·3) | -2·4 (-3·0 to -1·7) | <0·0001 | <0·0001 | | < 3·3 mmol/L | 0·8 (0·1) | 2·0 (0·2) | -1·3 (-1·6 to -0·9) | <0·0001 | <0·0001 | | < 2·8 mmol/L | 0·2 (0·1) | 0·7 (0·1) | -0·5 (-0·7 to -0·3) | <0·0001 | <0·0001 | | HbA1c change (%) | -0·29 (0·07) | -0·14 (0·07) | -0·15 (-0·33 to 0·03) | 0·098 | | | HbA1c change (mmol/mol) | -3·20 (0·73) | -1·57 (0·71) | -1·63 (-3·57 to 0·31) | 0·098 | | | Glucose concentration (mmol/L) | 8·7 (0·1) | 9·1 (0·1) | -0·4 (-0·6 to -0·1) | 0·012 | | | Coefficient of variation of glucose (%) | 31·0 (0·5) | 33·3 (0·5) | -2·3 (-3·1 to -1·5) | <0·0001 | | | LBGI | 0·6 (0·1) | 1·1 (0·1) | -0·5 (-0·6 to -0·4) | <0·0001 | | | HBGI | 6·7 (0·3) | 8·4 (0·3) | -1·7 (-2·6 to -0·9) | <0·001 | | | BGRI | 7·3 (0·3) | 9·5 (0·3) | -2·2 (-3·0 to -1·4) | <0·0001 | | Data are mean (SE) or mean (95% CI). No significant period effect was observed. * Model adjusted for baseline HbA1c and site. Difference is closed-loop period minus open-loop period. ** p-value of the log-transformed sensitivity analysis. † Primary endpoint. Table 3. Serious adverse events (safety set) | SAE : number of events | Closed-loop period (n=68) | Control period (n=68) | |--------------------------|-----------------------------|-------------------------| | (number of patients) | | | | Diabetic ketoacidosis | 0 | 0 | | Severe hyperglycaemia * | 9 (4) | 0 | | Severe hypoglycaemia † | 5 (5)‡ | 3 (3)‡ | Data are n. * Defined as capillary blood glucose of more than 20 mmol/L. † Defined as intervention of a third party for correction of hypoglycemia. ‡ During closed-loop period, 3 episodes of severe hypoglycaemia occurred during period 1 due to hardware dysfunction and 2 episodes during period 2 due to human errors. During open-loop period, 2 episodes of severe hypoglycaemia occurred during period 1 and 1 episode during period 2.
- 17. El-Khatib FH, Balliro C, Hillard MA, et al. Home use of a bihormonal bionic pancreas versus insulin pump therapy in adults with type 1 diabetes: a multicentre randomised crossover trial. Lancet 2017; 389 : 369-80.
- 15. Garg SK, Brazg RL, Bailey TS, et al. Hypoglycemia Begets Hypoglycemia: The Order Effect in the ASPIRE In-Clinic Study. Diabetes Technol Ther 2014; 16 : 125-30.
Cited by
New closed-loop insulin systems
Boughton, C. K., & Hovorka, R. (2021) · Diabetologia · doi:10.1007/s00125-021-05391-w · Cited by 270
“Even with closed-loop glucose-responsive insulin delivery, users usually need to plan for exercise, announcing exercise to the algorithm in advance, and may still require carbohydrate intake to prevent hypoglycaemia [31, 32].”
BackgroundAdolfsson, P., Taplin, C. E., Zaharieva, D. P., Pemberton, J. S., Davis, E. A., Riddell, M. C., McGavock, J., Moser, O., Szadkowska, A., Lopez, P. E., et al. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13452 · Cited by 203
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Exercise in adults with type 1 diabetes mellitus
Riddell, M. C., & Peters, A. L. (2022) · Nature Reviews Endocrinology · doi:10.1038/s41574-022-00756-6 · Cited by 148
“should be deemed advantageous but might require a bolus insulin dose reduction at the pre-exercise meal if the activity is ≥45 min (refs.(158,159)).”
BackgroundMoser, O., Zaharieva, D. P., Adolfsson, P., Battelino, T., Bracken, R. M., Buckingham, B. A., Danne, T., Davis, E. A., Dovč, K., Forlenza, G. P., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06308-z · Cited by 111
“In general, we recommend keeping the MiniMed 780G system in automated mode during PA when a glucose decrease is expected, in addition to setting a Temp Target, and reducing prandial bolus insulin by 25–33% to minimise hypoglycaemia [50, 51].”
Self-citation
Metadata
- Authors
- Tagougui, S., Taleb, N., Legault, L., Suppère, C., Messier, V., Boukabous, I., Shohoudi, A., Ladouceur, M., & Rabasa-Lhoret, R.
- Affiliations
- Université de Lille (FR)
- Montreal Clinical Research Institute (CA)
- Montreal Children's Hospital (CA)
- Montreal Heart Institute (CA)
- Université de Montréal (CA)
- Centre Hospitalier de l’Université de Montréal (CA)
- Corresponding author
- Rabasa-Lhoret, Rémi
- ORCID
- Venue
- Diabetologia
- Published
- 2020-08-01
- Volume
- 63
- Issue
- 11
- Pages
- 2282-2291
- ISSN
- 0012-186X (ISSN-L)
- 1432-0428
- OpenAlex
- W3046283197
- Cited by
- 40
- References
- 38
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 12 · 2023: 8 · 2022: 9 · 2021: 3
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- green
- lilloa.hal.science
- Licence
- cc-by-nc
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Diabetologia (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion, cc-by-nc)
- LillOA (Université de Lille (University Of Lille)) (submittedVersion, other-oa)
- LillOA (Université de Lille (University Of Lille)) (submittedVersion)
- Funders
- Canadian Institutes of Health Research (354024)
- Juvenile Diabetes Research Foundation Canada (2-SRA-2016-210-A-N)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, artificial pancreas, hypoglycemia, physical activity, postprandial exercise, prandial insulin, glycemic variability, hypoglycemia risk, continuous glucose monitoring, insulin pump, time in range, HbA1c
- MeSH terms
- Adult, Blood Glucose, Diabetes Mellitus, Type 1, Female, Humans, Hypoglycemia, Male, Middle Aged, Exercise, Single-Blind Method, Cross-Over Studies, Postprandial Period
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.