CoChat

Single- and Dual-Hormone Artificial Pancreas for Overnight Glucose Control in Type 1 Diabetes

Haidar, Ahmad, Rabasa-Lhoret, Rémi, Legault, Laurent, Lovblom, Leif E., Rakheja, Rohan, Messier, Virginie, D'Aoust, Émilie, Falappa, C. Marcelo, Justice, Tara, Orszag, Andrej, Tschirhart, Holly, Dallaire, Maryse, Ladouceur, Martin, Perkins, Bruce A. · 2016 · The Journal of Clinical Endocrinology & Metabolism
Cited by 89

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

CONTEXT: The added benefit of glucagon in artificial pancreas systems for overnight glucose control in type 1 diabetes has not been fully explored. OBJECTIVE: The objective of the study was to compare the efficacy of dual-hormone (insulin and glucagon) artificial pancreas, single-hormone (insulin alone) artificial pancreas, and conventional insulin pump therapy. DESIGN: This study was a three-center, three-arm, open-label, randomized, crossover controlled trial involving three interventions, each applied over a night after a high carbohydrate/high fat meal and a second after exercise to mimic real-life glycemic excursions. SETTING: The study was conducted in a home setting. PATIENTS: Twenty-eight type 1 diabetes participants (21 adults and seven adolescents) participated in the study. INTERVENTIONS: Dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional pump therapy was activated from 9:00 PM to 7:00 AM. MAIN OUTCOME: The main outcome was a proportion of time in target (4-8 mmol/L) by continuous glucose monitoring from 11:00 PM to 7:00 AM. Analysis was by intention to treat. RESULTS: The median (interquartile range) percentage of time-in-target glucose range was 47% (36%-71%) for conventional therapy, higher on both single-hormone (76% [65%-91%], P < .001) and dual-hormone artificial pancreas (81 [68%-93%], P < .001). The median (interquartile range) time spent below 4 mmol/L was 14% (4%-28%) for conventional therapy, lower on both single-hormone (5% [0%-13%], P = .004) and dual-hormone artificial pancreas (1% [0%-8%], P < .001). There were 14 hypoglycemic events on conventional therapy compared with six incidences on the single-hormone artificial pancreas (P = .059) and three incidences on the dual-hormone artificial pancreas (P = .017). None of these outcomes differed significantly between single- and dual-hormone configurations. CONCLUSIONS: Single- and dual-hormone artificial pancreas systems both provided better glucose control than conventional therapy. Although the dual-hormone configuration did not increase overnight time-in-target glucose levels, an effect on lowering hypoglycemia risk cannot be ruled out.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2015-3003

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 89

Metadata

Authors
Haidar, A., Rabasa-Lhoret, R., Legault, L., Lovblom, L. E., Rakheja, R., Messier, V., D'Aoust, É., Falappa, C. M., Justice, T., Orszag, A., Tschirhart, H., Dallaire, M., Ladouceur, M., & Perkins, B. A.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2016-01
Volume
101
Issue
1
Pages
214-223
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W1918064491
Cited by
89
References
10
FWCI
7.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single- and Dual-Hormone Artificial Pancreas for Overnight Glucose Control in Type 1 Diabetes. https://app.cochat.ai/papers/10.1210/jc.2015-3003
The paper
Haidar, A., Rabasa-Lhoret, R., Legault, L., Lovblom, L. E., Rakheja, R., Messier, V., D'Aoust, É., Falappa, C. M., Justice, T., Orszag, A., Tschirhart, H., Dallaire, M., Ladouceur, M., & Perkins, B. A. (2016). Single- and Dual-Hormone Artificial Pancreas for Overnight Glucose Control in Type 1 Diabetes. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jc.2015-3003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.