Tight glycaemic control by an automated algorithm with time-variant sampling in medical ICU patients
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Objective Tight glycaemic control (TGC) in critically ill patients improves clinical outcome, but is difficult to establish The primary objective of the present study was to compare glucose control in medical ICU patients applying a computer-based enhanced model predictive control algorithm (eMPC) extended to include time-variant sampling against an implemented glucose management protocol.Design Open randomised controlled trial.Setting Nine-bed medical intensive care unit (ICU) in a tertiary teaching hospital.Patients and participants Fifty mechanically ventilated medical ICU patients.Interventions Patients were included for a study period of up to 72 h. Patients were randomised to the control group (n = 25), treated by an implemented insulin algorithm, or to the eMPC group (n = 25), using the laptop-based algorithm. Target range for blood glucose (BG) was 4.4-6.1 mM. Efficacy was assessed by mean BG, hyperglycaemic index (HGI) and BG sampling interval. Safety was assessed by the number of hypoglycaemic-episodes < 2.2 mM. Each participating nurse filled-in a questionnaire regarding the usability of the algorithm.Measurements and main results BG and HGI were significantly lower in the eMPC group [BG 5.9 mM (5.5-6.3), median (IQR); HGI 0.4 mM (0.2-0.9)] than in control patients [BG 7.4 mM (6.9-8.6), p < 0.001; HGI 1.6 mM (1.1-2.4), p < 0.001]. One hypoglycaemic episode was detected in the eMPC group; no such episodes in the control group. Sampling interval was significantly shorter in the eMPC group [eMPC 117[Symbol: see text]min (+/- 34), mean (+/- SD), vs 174 min (+/- 27); p < 0.001]. Thirty-four nurses filled-in the questionnaire. Thirty answered the question of whether the algorithm could be applied in daily routine in the affirmative.Conclusions The eMPC algorithm was effective in maintaining tight glycaemic control in severely ill medical ICU patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“most hospitals use institutional-based, nurse-driven protocols, with several validated protocols published.1291–1293”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1291]
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2210-z · Cited by 3,321
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000117317.18092.e4 · Cited by 3,018
Capes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187
Dellinger, R. P. (2004) · Critical Care Medicine · Cited by 1,848
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Self-citationMcCowen, K. C., Malhotra, A., & Bistrian, B. R. (2001) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70154-8 · Cited by 1,170
Furnary, A. P., Gao, G., Grunkemeier, G. L., Wu, Y., Zerr, K. J., Bookin, S. O., Floten, H. S., & Starr, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.181 · Cited by 1,130
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Hyperglycaemic index as a tool to assess glucose control: a retrospective study
Vogelzang, M., van der Horst, I. C., & Nijsten, M. W. (2004) · Critical Care · doi:10.1186/cc2840 · Cited by 507
Reliability of point-of-care testing for glucose measurement in critically ill adults*
Kanji, S., Buffie, J., Hutton, B., Bunting, P. S., Singh, A., McDonald, K., Fergusson, D., McIntyre, L. A., & Hebert, P. C. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000189939.10881.60 · Cited by 395
Admission Hyperglycemia as a Prognostic Indicator in Trauma
Yendamuri, S., Fulda, G. J., & Tinkoff, G. H. (2003) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000074434.39928.72 · Cited by 383
Pittas, A. G., Siegel, R. D., & Lau, J. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.18.2005 · Cited by 306
Predisposing factors for hypoglycemia in the intensive care unit*
Vriesendorp, T. M., van Santen, S., DeVries, J. H., de Jonge, E., Rosendaal, F. R., Schultz, M. J., & Hoekstra, J. B. L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000194536.89694.06 · Cited by 282
Kanji, S., Singh, A., Tierney, M., Meggison, H., McIntyre, L., & Hebert, P. C. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2252-2 · Cited by 208
Intensive Insulin Therapy in Critical Care
Wilson, M., Weinreb, J., & Hoo, G. W. S. (2007) · Diabetes Care · doi:10.2337/dc06-1964 · Cited by 206
Plank, J., Blaha, J., Cordingley, J., Wilinska, M. E., Chassin, L. J., Morgan, C., Squire, S., Haluzik, M., Kremen, J., Svacina, S., et al. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1689 · Cited by 195
Self-citationMeijering, S., Corstjens, A. M., Tulleken, J. E., Meertens, J. H., Zijlstra, J. G., & Ligtenberg, J. J. (2006) · Critical Care · doi:10.1186/cc3981 · Cited by 172
Accuracy of bedside capillary blood glucose measurements in critically ill patients
Critchell, C. D., Savarese, V. W., Callahan, A., Aboud, C., Jabbour, S. A., & Marik, P. E. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0835-4 · Cited by 156
Closing the Loop: The Adicol Experience
Hovorka, R., Chassin, L. J., Wilinska, M. E., Canonico, V., Akwi, J. A., Federici, M. O., Massi-Benedetti, M., Hutzli, I., Zaugg, C., Kaufmann, H., et al. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774197990 · Cited by 154
Self-citationVogelzang, M., Zijlstra, F., & Nijsten, M. W. (2005) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-5-38 · Cited by 139
Glycemic control in the ICU: a multicenter survey
Cook, D., McMullin, J., Brożek, J., Jaeschke, R., Hamielec, C. M., Dhingra, V. K., Rocker, G. M., Freitag, A. P., & Gibson, J. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2242-4 · Cited by 65
Evaluation of an intensive insulin protocol for septic patients in a medical intensive care unit*
Clayton, S. B., Mazur, J. E., Condren, S., Hermayer, K. L., & Strange, C. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000248906.10399.cf · Cited by 58
Mitchell, I., Finfer, S. R., Bellomo, R., & Higlett, T. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0135-4 · Cited by 53
Impact of bolus application of low-dose hydrocortisone on glycemic control in septic shock patients
Weber‐Carstens, S., Deja, M., Bercker, S., Dimroth, A., Ahlers, O., Kaisers, U., & Keh, D. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0540-3 · Cited by 53
Lachérade, J.-C., Jabre, P., Bastuji‐Garin, S., Grimaldi, D., Fangio, P., Théron, V., Outin, H., & Jonghe, B. D. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0543-0 · Cited by 50
Introduction and evaluation of a computerised insulin protocol
Meynaar, I. A., Dawson, L., Tangkau, P. L., Salm, E. F., & Rijks, L. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0484-z · Cited by 47
Hypoglycaemia: the limiting factor in the glycaemic management of the critically ill?
Cryer, P. E. (2006) · Diabetologia · doi:10.1007/s00125-006-0306-4 · Cited by 45
Subcutaneous glucose monitoring in patients with severe sepsis
Mader, J., Korsatko, S., Ikeoka, D., Plank, J., Bodenlenz, M., Suppan, M., Sinner, F. M., Smolle, K., Pieber, T. R., & Ellmerer, M. (2007) · Critical Care · doi:10.1186/cc5304 · Cited by 2
Self-citation
Cited by
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Intensive Insulin Therapy in Hospitalized Patients: A Systematic Review
Kansagara, D., Fu, R., Freeman, M., Wolf, F., & Helfand, M. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-4-201102150-00008 · Cited by 255
Computerized advice on drug dosage to improve prescribing practice
Durieux, P., Trinquart, L., Colombet, I., Niès, J., Walton, R., Rajeswaran, A., Rège-Walther, M., Harvey, E., & Burnand, B. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002894.pub2 · Cited by 253
Honarmand, K., Sirimaturos, M., Hirshberg, E. L., Bircher, N. G., Agus, M. S. D., Carpenter, D. L., Downs, C. R., Farrington, E. A., Freire, A. X., Grow, A., et al. (2024) · Critical Care Medicine · doi:10.1097/ccm.0000000000006174 · Cited by 202
Glucose variability measures and their effect on mortality: a systematic review
Eslami, S., Taherzadeh, Z., Schultz, M. J., & Abu–Hanna, A. (2011) · Intensive Care Medicine · doi:10.1007/s00134-010-2129-5 · Cited by 162
“Some studies showed that their implementation of glucose control with insulin comes with the risk of hypoglycemia [6, 7], others did not [8, 9].”
Background
Metadata
- Authors
- Pachler, C., Plank, J., Weinhandl, H., Chassin, L. J., Wilinska, M. E., Kulnik, R., Kaufmann, P., Smolle, K.-H., Pilger, E., Pieber, T. R., Ellmerer, M., & Hovorka, R.
- Affiliations
- Medical University of Graz (AT)
- University of Graz (AT)
- University of Cambridge (GB)
- Corresponding author
- Pachler, Christoph
- Venue
- Intensive Care Medicine
- Published
- 2008-02-23
- Volume
- 34
- Issue
- 7
- Pages
- 1224-1230
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- OpenAlex
- W1974872287
- Cited by
- 82
- References
- 32
- Citations by year
- 2026: 2 · 2024: 3 · 2022: 2 · 2021: 2 · 2020: 2 · 2019: 4 · 2018: 4 · 2017: 3 · 2016: 1 · 2015: 2 · 2014: 4 · 2013: 5 · 2012: 4
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Intensive Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- tight glycemic control, model predictive control, artificial pancreas, critically ill patients, mechanical ventilation, hyperglycemia, hypoglycemia, blood glucose monitoring, medical intensive care unit
- MeSH terms
- Algorithms, Blood Glucose, Critical Care, Diabetes Mellitus, Type 1, Drug Therapy, Computer-Assisted, Female, Humans, Hypoglycemic Agents, Insulin, Insulin Resistance, Intensive Care Units, Male, Middle Aged, Time Factors, APACHE, Glycemic Index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.