Tight glycaemic control by an automated algorithm with time-variant sampling in medical ICU patients
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Objective Tight glycaemic control (TGC) in critically ill patients improves clinical outcome, but is difficult to establish The primary objective of the present study was to compare glucose control in medical ICU patients applying a computer-based enhanced model predictive control algorithm (eMPC) extended to include time-variant sampling against an implemented glucose management protocol.Design Open randomised controlled trial.Setting Nine-bed medical intensive care unit (ICU) in a tertiary teaching hospital.Patients and participants Fifty mechanically ventilated medical ICU patients.Interventions Patients were included for a study period of up to 72 h. Patients were randomised to the control group (n = 25), treated by an implemented insulin algorithm, or to the eMPC group (n = 25), using the laptop-based algorithm. Target range for blood glucose (BG) was 4.4-6.1 mM. Efficacy was assessed by mean BG, hyperglycaemic index (HGI) and BG sampling interval. Safety was assessed by the number of hypoglycaemic-episodes < 2.2 mM. Each participating nurse filled-in a questionnaire regarding the usability of the algorithm.Measurements and main results BG and HGI were significantly lower in the eMPC group [BG 5.9 mM (5.5-6.3), median (IQR); HGI 0.4 mM (0.2-0.9)] than in control patients [BG 7.4 mM (6.9-8.6), p < 0.001; HGI 1.6 mM (1.1-2.4), p < 0.001]. One hypoglycaemic episode was detected in the eMPC group; no such episodes in the control group. Sampling interval was significantly shorter in the eMPC group [eMPC 117[Symbol: see text]min (+/- 34), mean (+/- SD), vs 174 min (+/- 27); p < 0.001]. Thirty-four nurses filled-in the questionnaire. Thirty answered the question of whether the algorithm could be applied in daily routine in the affirmative.Conclusions The eMPC algorithm was effective in maintaining tight glycaemic control in severely ill medical ICU patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“most hospitals use institutional-based, nurse-driven protocols, with several validated protocols published.1291–1293”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1291]
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2210-z · Cited by 3,321
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000117317.18092.e4 · Cited by 3,018
Capes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187
Dellinger, R. P. (2004) · Critical Care Medicine · Cited by 1,848
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Self-citationMcCowen, K. C., Malhotra, A., & Bistrian, B. R. (2001) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70154-8 · Cited by 1,170
Cited by
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Intensive Insulin Therapy in Hospitalized Patients: A Systematic Review
Kansagara, D., Fu, R., Freeman, M., Wolf, F., & Helfand, M. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-4-201102150-00008 · Cited by 255
Computerized advice on drug dosage to improve prescribing practice
Durieux, P., Trinquart, L., Colombet, I., Niès, J., Walton, R., Rajeswaran, A., Rège-Walther, M., Harvey, E., & Burnand, B. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002894.pub2 · Cited by 253
Honarmand, K., Sirimaturos, M., Hirshberg, E. L., Bircher, N. G., Agus, M. S. D., Carpenter, D. L., Downs, C. R., Farrington, E. A., Freire, A. X., Grow, A., et al. (2024) · Critical Care Medicine · doi:10.1097/ccm.0000000000006174 · Cited by 202
Glucose variability measures and their effect on mortality: a systematic review
Eslami, S., Taherzadeh, Z., Schultz, M. J., & Abu–Hanna, A. (2011) · Intensive Care Medicine · doi:10.1007/s00134-010-2129-5 · Cited by 162
“Some studies showed that their implementation of glucose control with insulin comes with the risk of hypoglycemia [6, 7], others did not [8, 9].”
BackgroundRoumeliotis, N., Sniderman, J., Adams-Webber, T., Addo, N., Anand, V., Rochon, P., Taddio, A., & Parshuram, C. (2019) · Journal of General Internal Medicine · doi:10.1007/s11606-019-05236-8 · Cited by 137
International recommendations for glucose control in adult non diabetic critically ill patients
Ichai, C., Preiser, J.-C., (SFAR), F. T. S. F. D.-R., & Société de Réanimation de langue Française (SRLF) and the Experts group (2010) · Critical Care · doi:10.1186/cc9258 · Cited by 127
“Dedicated computer software is being developed [76,77,97-99].”
BackgroundMethodInfluentialThe use of reinforcement learning algorithms to meet the challenges of an artificial pancreas
Bothe, M. K., Dickens, L., Reichel, K., Tellmann, A., Ellger, B., Westphal, M., & Faisal, A. A. (2013) · Expert Review of Medical Devices · doi:10.1586/17434440.2013.827515 · Cited by 124
“The components required for an artificial pancreas are (1) continuous glucose”
BackgroundLeelarathna, L., English, S. W., Thabit, H., Caldwell, K., Allen, J. M., Kumareswaran, K., Wilinska, M. E., Nodale, M., Mangat, J., Evans, M. L., et al. (2013) · Critical Care · doi:10.1186/cc12838 · Cited by 120
“These can range from written guidelines [12,13] and protocols [37-40] to elementary [41,42] and advanced computerized algorithms [43-48].”
BackgroundSelf-citationClinical Practice Guideline: Safe Medication Use in the ICU
Kane‐Gill, S. L., Dasta, J. F., Buckley, M. S., Devabhakthuni, S., Liu, M., Cohen, H., GEORGE, E. L., Pohlman, A. S., Agarwal, S., Henneman, E. A., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002533 · Cited by 134
A simulation model of glucose regulation in the critically ill
Hovorka, R., Chassin, L. J., Ellmerer, M., Plank, J., & Wilinska, M. E. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/8/008 · Cited by 101
Self-citationComparison of Three Protocols for Tight Glycemic Control in Cardiac Surgery Patients
Blaha, J., Kopecky, P., Matias, M., Hovorka, R., Kunstyr, J., Kotulak, T., Lips, M., Rubes, D., Stritesky, M., Lindner, J., et al. (2009) · Diabetes Care · doi:10.2337/dc08-1851 · Cited by 98
“We performed a monocenter randomized trial and compared a protocol based on the absolute glucose value, the Matias protocol (15,17); a protocol based on the relative glucose change, the Bath protocol (19); and a computer-based model predictive control algorithm with variable sampling rate (eMPC) (16) developed within…”
MethodSelf-citationThe metrics of glycaemic control in critical care
Mackenzie, I. M. J., Whitehouse, T., & Nightingale, P. (2011) · Intensive Care Medicine · doi:10.1007/s00134-010-2103-2 · Cited by 598
“Glucose metrics identified from a review of the literature included the average (AVG) [6, 20], TAG [23, 24], median (MED) [25–27], SD [20–22, 28, 29], coefficient of variation (CV) [29, 30], maximum (MAX) [6, 20, 31, 32], hyperglycaemic index (HI) [24, 33–35], glycaemic lability index (GLI) [21, 36] and mean amplitude…”
BackgroundJuneja, R., Roudebush, C. P., Nasraway, S. A., Golas, A. A., Jacobi, J., Carroll, J., Nelson, D., Abad, V. J., & Flanders, S. J. (2009) · Critical Care · doi:10.1186/cc8129 · Cited by 86
“On the other hand, computerized applications, which enable rapid, complex calculations for recommended insulin infusion rates, have demonstrated superior overall efficacy and safety in some reports [ 22-26 ], and failed to improve glycemic control or reduce hypoglycemia in others [27,28] when compared with manual prot…”
BackgroundGlucose Control in the ICU: A Continuing Story
Preiser, J., Chase, J. G., Hovorka, R., Joseph, J. I., Krinsley, J. S., Block, C. E. M. D., Desaive, T., Foubert, L. A., Kalfon, P., Pielmeier, U., et al. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816648713 · Cited by 88
Self-citationA Review of Closed-Loop Algorithms for Glycemic Control in the Treatment of Type 1 Diabetes
El Youssef, J., Castle, J., & Ward, W. K. (2009) · Algorithms · doi:10.3390/a2010518 · Cited by 69
“Further trials in both surgical and medical intensive care settings have provided similar results with MPC algorithm-controlled glucose systems [25].”
ResultCavalcanti, A. B., Silva, E., Pereira, A. J., Filho, M. C., de Almeida, F. P., Westphal, G. A., Beims, R., Fernandes, C. C. F., Corrêa, T. D., Gouvea, M. R., et al. (2009) · Journal of Critical Care · doi:10.1016/j.jcrc.2009.05.005 · Cited by 63
“More recently, randomized trials were conducted to compare a nonlinear model predictive control algorithm delivered by a computerized system with conventional strict glucose control protocol [10,11].”
MethodTight glycemic control and computerized decision-support systems: a systematic review
Eslami, S., Abu-Hanna, A., de Jonge, E., & de Keizer, N. F. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1542-0 · Cited by 64
“One article [15, 16] Hypoglycemia-related indicator ( proxy for safety ) Hypoglycemia events \ 40 [7, 9, 15, 22, 23, 25, 27], B 40 [9, 22, 25, 28], \ 50 [7, 10, 11, 26], \ 60 [7, 24], and \ 70 [25] were used as thresholds for defining a BGL as hypoglycemia event.”
BackgroundMethodDiabetes technology in the inpatient setting for management of hyperglycemia
Davis, G. M., Galindo, R. J., Migdal, A. L., & Umpierrez, G. E. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.11.002 · Cited by 62
Kopecký, P., Mráz, M., Bláha, J., Lindner, J., Svačina, Š., Hovorka, R., & Haluzík, M. (2013) · BioMed Research International · doi:10.1155/2013/186439 · Cited by 55
“The eMPC algorithm proved its effectiveness in maintaining target glycemia in several clinical trials [9, 30–32].”
MethodSelf-citationChase, J. G., Desaive, T., Bohé, J., Cnop, M., Block, C. E. M. D., Gunst, J., Hovorka, R., Kalfon, P., Krinsley, J. S., Renard, É., et al. (2018) · Critical Care · doi:10.1186/s13054-018-2110-1 · Cited by 58
Self-citationIntensive Care Unit Insulin Delivery Algorithms: Why So Many? How to Choose?
Steil, G. M., Deiss, D., Shih, J. L., Buckingham, B. A., WEINZIMER, S. A., & Agus, M. S. D. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300114 · Cited by 51
Organ dysfunction is associated with hyperglycemia in critically ill children
Kyle, U. G., Bu, J. C., Kennedy, C. E., & Jefferson, L. S. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1703-1 · Cited by 54
“This is similar to previous recommendations by others [43].”
ResultUpdate on glucose in critical care
Lheureux, O., Prevedello, D., & Preiser, J. (2018) · Nutrition · doi:10.1016/j.nut.2018.06.027 · Cited by 60
“computer-guided protocols have been developed for this approach, including the Stochastic TARgeted (STAR) approach [56], the LOGIC-Insulin algorithm [57], enhanced model predictive control (eMPC) algorithm [58], Glucose Regulation for Intensive care Patients (GRIP) [59], and the Glucosafe, and Contrôle Glyc emique Ass…”
MethodGlycemic control in the intensive care unit: A control systems perspective
Chase, J. G., Benyó, B. I., & Desaive, T. (2019) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2019.03.007 · Cited by 50
Hoekstra, M., Vogelzang, M., Verbitskiy, E. A., & Nijsten, M. W. (2009) · Critical Care · doi:10.1186/cc8023 · Cited by 47
“Table 1 summarizes the 19 identified studies [13, 21-38 ].”
BackgroundAP@home: A Novel European Approach to Bring the Artificial Pancreas Home
Heinemann, L., Benesch, C., & DeVries, J. H. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500607 · Cited by 41
Barriers and facilitators to the use of computer-based intensive insulin therapy
Campion, T. R., Waitman, L. R., Lorenzi, N. M., May, A. K., & Gadd, C. S. (2011) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2011.10.003 · Cited by 38
“Capturing more parameters in IIT CDSS could also facilitate use of more sophisticated dosing algorithms that incorporate dextrose sources [32].”
Feasibility of automated insulin delivery guided by continuous glucose monitoring in preterm infants
Beardsall, K., Thomson, L. M., Elleri, D., Dunger, D. B., & Hovorka, R. (2019) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2019-316871 · Cited by 39
Self-citationEvans, R. P., Bryant, L. D., Russell, G., & Absolom, K. L. (2024) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2024.105342 · Cited by 41
Wilinska, M. E., & Hovorka, R. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2014.225326 · Cited by 35
Self-citationNutrition delivery of a model-based ICU glycaemic control system
Stewart, K. W., Chase, J. G., Pretty, C. G., & Shaw, G. M. (2018) · Annals of Intensive Care · doi:10.1186/s13613-017-0351-9 · Cited by 29
Amrein, K., Ellmerer, M., Hovorka, R., Kachel, N., Fries, H., von Lewinski, D., Smolle, K., Pieber, T. R., & Plank, J. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0021 · Cited by 250
“18,21 In brief, SGC alerts the nurse of the time until the suggested sample has elapsed, who then measures and enters a current blood glucose value in order to receive an advice regarding insulin dose and time for the next glucose measurement (between 30 and 240 min).”
Self-citationEslami, S., Abu–Hanna, A., de Keizer, N. F., Bosman, R. J., Spronk, P. E., de Jonge, E., & Schultz, M. J. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1924-3 · Cited by 26
“Although some studies showed that the implementation of GC with insulin came with the risk of hypoglycemia [5, 6, 11–13], others did not [14–18].”
Amrein, K., Ellmerer, M., Hovorka, R., Kachel, N., Parcz, D., Korsatko, S., Smolle, K., Perl, S., Bock, G., Doll, W., et al. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0147 · Cited by 28
“The handling of the lap-top-based software algorithm version has been described in detail elsewhere 17 and is shown in Figure 1.”
InfluentialSelf-citationGlycemic targets in critically ill adults: A mini-review
See, K. C. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i10.1719 · Cited by 28
Rabinovich, M., Grahl, J., Durr, E. A., Gayed, R. M., Chester, K. W., McFarland, R., & McLean, B. A. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817747617 · Cited by 28
“The eGMS methods result in tighter, faster, and less variable control, with less associated hypoglycemia.(16-20) Fogel and colleagues also discovered a temporal decrease in healthcare-acquired infections (ventilator-associated pneumonia, catheter-associated urinary tract infections, and central lineassociated blood st…”
MethodEvaluating Glycemic Control Algorithms by Computer Simulations
Wilinska, M. E., Bláha, J., Chassin, L. J., Cordingley, J. J., Dormand, N. C., Ellmerer, M., Haluzík, M., Plank, J., Vlasselaers, D., Wouters, P. J., et al. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0016 · Cited by 25
“…(trials described in Plank et al. 33 and Hovorka et al. 18 ); Medical University, Graz (MUG), Austria (trials re-ported by Plank et al. 33 and Pachler et al. 34 ); Katholieke Uni-versiteit, Leuven (KUL), Belgium (trials reported by Cordingley et al. 35 and Van Cromphaut et al. 36 ); and…”
Self-citationAmrein, K., Kachel, N., Fries, H., Hovorka, R., Pieber, T. R., Plank, J., Wenger, U., Lienhardt, B., & Maggiorini, M. (2014) · BMC Endocrine Disorders · doi:10.1186/1472-6823-14-62 · Cited by 28
“The enhanced Model Predictive Control (eMPC) algorithm has been studied in several clinical trials where it was found to be efficient and safe [22-27].”
MethodSelf-citationCampion, T. R., May, A. K., Waitman, L. R., Özdaş, A., Lorenzi, N. M., & Gadd, C. S. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000129 · Cited by 22
“and more sophisticated quadratic or model-based approaches might lead to better performance.”
BackgroundKulnik, R., Plank, J., Pachler, C., Wilinska, M. E., Groselj‐Strele, A., Röthlein, D., Wufka, M., Kachel, N., Smolle, K. H., Perl, S., et al. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200606 · Cited by 23
Self-citationThe Future is Now: Software-Guided Intensive Insulin Therapy in the Critically Ill
Rattan, R., & Nasraway, S. A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700231 · Cited by 22
Sato, H., Carvalho, G., Sato, T., Bracco, D., Codère-Maruyama, T., Lattermann, R., Hatzakorzian, R., Matsukawa, T., & Schricker, T. (2010) · Nutrition · doi:10.1016/j.nut.2009.10.005 · Cited by 21
The effects of clinical decision support systems on insulin use: A systematic review
Jia, P., Jia, P., Chen, J., Zhao, P., & Zhang, M. (2019) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.13291 · Cited by 18
Antonelli, M. M., Azoulay, É., Bonten, M. J. M., Chastre, J. E., Citerio, G., Conti, G., Backer, D. D., Lemaire, F., Gerlach, H., Groeneveld, J., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1371-6 · Cited by 13
“[30] evaluated their algorithm in a small randomized study.”
MethodNutrition Informatics Applications in Clinical Practice: a Systematic Review.
North, J., Jordan, K. C., Metos, J., & Hurdle, J. F. (2015) · PubMed Central · Cited by 17
Computer protocols: how to implement
Morris, A. H., Hirshberg, E. L., & Sward, K. A. (2009) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2008.09.002 · Cited by 13
Lee, J.-S., Jwa, C., Yi, H.-J., & Chun, H.-J. (2010) · Journal of Korean Neurosurgical Society · doi:10.3340/jkns.2010.48.2.99 · Cited by 13
In Silico Evaluation of Glucose Control Protocols for Critically Ill Patients
Lee, J. C., Kim, M., Choi, K. R., Oh, T. J., Kim, M. Y., Cho, Y. M., Kim, K., Kim, H. C., & Kim, S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163310 · Cited by 8
Xu, B., Jiang, W., Wang, C.-Y., Weng, L., Hu, X.-Y., Peng, J., & Du, B. (2017) · Chinese Medical Journal · doi:10.4103/0366-6999.213422 · Cited by 10
“As described previously,[14,18] glucose measurement, insulin perfusion rate, and infusion rate of specific enteral and parenteral nutrition are the input variables for the SGC.”
MethodBeardsall, K., Thomson, L., Guy, C., Bond, S. J., Allison, A., Pantaleo, B., Petrou, S., Kim, S. W., Dunger, D. B., & Hovorka, R. (2021) · Efficacy and Mechanism Evaluation · doi:10.3310/eme08160 · Cited by 8
Self-citationPatient-Specific Insulin-Resistance–Guided Infusion Improves Glycemic Control in Cardiac Surgery
Caddell, K. A., Komanapalli, C. B., Slater, M. S., Hagg, D. S., Tibayan, F. A., Smith, S. M., Ahmann, A., Guyton, S. W., & Song, H. K. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.05.054 · Cited by 7
Ichaï, C. (2009) · Nutrition Clinique et Métabolisme · doi:10.1016/j.nupar.2009.10.008 · Cited by 6
Faulds, E. R., Rayan, M. N., Mlachak, M. K., Dungan, K. M., Allen, T., & Patterson, E. S. (2026) · Diabetology · doi:10.3390/diabetology7010019 · Cited by 7
“A Settings included ICUs [25,27,31,32,34,35,37,38,40,42–50] and hospital-wide or general medical/surgical wards [26–29”
An Evaluation of “I, Pancreas” Algorithm Performance In Silico
Wilinska, M. E., & Nodale, M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300433 · Cited by 5
Self-citationArcher, J. R. H., Misra, S., Simmgen, M., Jones, P. W., & Baker, E. H. (2011) · BMJ Open · doi:10.1136/bmjopen-2011-000210 · Cited by 7
“Other studies have found that computerised decision support further improved glycaemic control.(22) A key aim of our study was to determine the safety of tight glycaemic control on the acute medical unit.”
BackgroundImproving blood sugar control during critical illness: A cohort study
O’Connor, E., Tragen, D., Fahey, P. P., Robinson, M. W., & Cremasco, T. (2009) · Journal of Critical Care · doi:10.1016/j.jcrc.2008.10.008 · Cited by 4
“These include a Web-based titration calculator [17], the presence of a nurse quality supervisor [18], use of a standardized insulin adjustment protocol [10-13,19-21], and use of a nomogram for insulin administration in place of the traditional insulin sliding scale [15].”
MethodAutomatisation du contrôle strict de la glycémie en réanimation
Kalfon, P. (2009) · Réanimation · doi:10.1016/j.reaurg.2009.05.015 · Cited by 4
Robust Tight Glycaemic Control of ICU patients
Kovács, L., Szalay, P., Benyó, B. I., & Chase, J. G. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.02852 · Cited by 4
“The goal of such a control can be realized by automated or semiautomated treatments and, in this way, good outcome can be achieved with minimal extra clinical effort (Chase et al. (2006), Pachler et al. (2008)).”
BackgroundA sweet debate: Glycemic control in the intensive care unit*
van den Heuvel, I. A., & Ellger, B. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31818f2831 · Cited by 4
Evaluation and Enhancement of an Intraoperative Insulin Infusion Protocol via In-Silico Simulation
Kohl, B., Chen, S., Mullen‐Fortino, M., & Lee, I. (2013) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi.2013.43 · Cited by 5
“Protocols that take into account prior glucose readings and rates of change have been more successful but are far from foolproof [34], [35], [36], [37], [38], [39], [40].”
Monge, F. J. C., Lareo, M. M., Gómez, S. G., Pérez, A. J., Varela, R. A., Herranz, C. Q., Rodríguez, G. M. R., & González, I. C. (2012) · Enfermería Intensiva · doi:10.1016/j.enfi.2011.12.005 · Cited by 3
Tight Glycemic Control in the Hospital
Ellmerer, M., Pachler, C., & Plank, J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200427 · Cited by 3
Self-citationArtificial intelligence in critically ill diabetic patients: current status and future prospects
Juneja, D., Gupta, A., & Singh, O. (2022) · Artificial Intelligence in Gastroenterology · doi:10.35712/aig.v3.i2.66 · Cited by 3
A stochastic model-based control methodology for glycemic management in the intensive care unit
Sirlanci, M., Hripcsak, G. M., Wang, C. C. L., Stroh, J. N., Wang, Y., Bennett, T. D., Stuart, A. M., & Albers, D. J. (2024) · Frontiers in Medical Engineering · doi:10.3389/fmede.2024.1419786 · Cited by 2
“These results provide evidence that personalized treatment could increase the success rate at the individual level compared to standard one-fits-all approaches.”
de Watteville, A., Pielmeier, U., Graf, S., Siegenthaler, N., Plockyn, B., Andreassen, S., & Heidegger, C. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00502-1 · Cited by 4
Glycemic Control in the Diabetic Patient After Stroke
Lee, L. T. (2009) · Critical Care Nursing Clinics of North America · doi:10.1016/j.ccell.2009.08.002 · Cited by 2
Razak, A. R. B. A. (2012) · UC Research Repository (University of Canterbury) · doi:10.26021/2810 · Cited by 3
Automated optimal glycaemic control using a physiology based pharmacokinetic, pharmacodynamic model
Schaller, S., Schuppert, A., & Mitsos, A. (2015) · RWTH Publications (RWTH Aachen) · Cited by 6
Validating medical digital twins for clinical decision support: beyond predictive accuracy
Vallée, A. (2026) · JAMIA Open · doi:10.1093/jamiaopen/ooag160 · Cited by 2
Hospital Strategies for Insulin Therapy with Rapid-Acting Insulin Analogs
Campbell, R. K. (2011) · Hospital Pharmacy · doi:10.1310/hpj4608-580 · Cited by 1
Automatisation du contrôle strict de la glycémie en réanimation
Kalfon, P. (2010) · Nutrition Clinique et Métabolisme · doi:10.1016/j.nupar.2010.02.004 · Cited by 1
Vogelzang, M., Verbitskiy, E. A., Nijsten, M. W., & Hoekstra, M. (2009) · Cited by 1
Endocrine disorders in the critically ill
Hall, G., Hunter, J. M., & Cooper, M. S. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511750441.015 · Cited by 1
Penning, S. (2014) · ORBi (University of Liège) · Cited by 1
Microdialysis Used to Measure the Metabolism of Glucose, Lactate, and Glycerol
Nowak, G. (2011) · Wiley eBooks · doi:10.1002/9781118011294.ch9
Ichaï, C. (2010) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(10)70104-8 · Cited by 2
Survey about diffusion and adoption of glycaemic controller in European intensive care units
Penning, S., Pironet, A., Chase, J. G., Pretty, C. G., & Desaive, T. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.01949
“…et al., 2008), Clarian GlucoStabilizer (Juneja et al., 2009), GRIP (Vogelzang et al., 2005, Vogelzang et al., 2008), eMPC (Amrein et al., 2012, Pachler et al., 2008), Glucosafe (Pielmeier et al., 2010, Pielmeier et al., 2012), SPRINT (Chase et al., 2008, Chase et al., 2010), and STAR (Evans…”
BackgroundThe Impact of Insulin and Insulin Therapy on Physiology in Critical Illness
Suhaimi, F. M. (2012) · UC Research Repository (University of Canterbury) · doi:10.26021/1869
Tight glucose control using intensive insulin therapy in the critically ill
Seubert, M. E., Khan, S., & Groeneveld, A. B. J. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511750441.016
Advances in Glucose Monitoring and Insulin Therapy in Intensive Care Unit Patients
Kim, T. N. (2018) · Journal of Korean Diabetes · doi:10.4093/jkd.2018.19.4.224
(2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1240-3
Metadata
- Authors
- Pachler, C., Plank, J., Weinhandl, H., Chassin, L. J., Wilinska, M. E., Kulnik, R., Kaufmann, P., Smolle, K.-H., Pilger, E., Pieber, T. R., Ellmerer, M., & Hovorka, R.
- Affiliations
- Medical University of Graz (AT)
- University of Graz (AT)
- University of Cambridge (GB)
- Corresponding author
- Pachler, Christoph
- Venue
- Intensive Care Medicine
- Published
- 2008-02-23
- Volume
- 34
- Issue
- 7
- Pages
- 1224-1230
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- OpenAlex
- W1974872287
- Cited by
- 82
- References
- 32
- Citations by year
- 2026: 2 · 2024: 3 · 2022: 2 · 2021: 2 · 2020: 2 · 2019: 4 · 2018: 4 · 2017: 3 · 2016: 1 · 2015: 2 · 2014: 4 · 2013: 5 · 2012: 4
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Intensive Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- tight glycemic control, model predictive control, artificial pancreas, critically ill patients, mechanical ventilation, hyperglycemia, hypoglycemia, blood glucose monitoring, medical intensive care unit
- MeSH terms
- Algorithms, Blood Glucose, Critical Care, Diabetes Mellitus, Type 1, Drug Therapy, Computer-Assisted, Female, Humans, Hypoglycemic Agents, Insulin, Insulin Resistance, Intensive Care Units, Male, Middle Aged, Time Factors, APACHE, Glycemic Index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.