The DOI matches its Crossref record; 124 of the 124 references it cites were found in a registry or an index.
Bioreactor monitoring with spectroscopy and chemometrics: a review
Abstract
Biotechnological processes are crucial to the development of any economy striving to ensure a relevant position in future markets. The cultivation of microorganisms in bioreactors is one of the most important unit operations of biotechnological processes, and real-time monitoring of bioreactors is essential for effective bioprocess control. In this review, published material on the potential application of different spectroscopic techniques for bioreactor monitoring is critically discussed, with particular emphasis on optical fiber technology, reported for in situ bioprocess monitoring. Application examples are presented by spectroscopy type, specifically focusing on ultraviolet-visible, near-infrared, mid-infrared, Raman, and fluorescence spectroscopy. The spectra acquisition devices available and the major advantages and disadvantages of each spectroscopy are discussed. The type of information contained in the spectra and the available chemometric methods for extracting that information are also addressed, including wavelength selection, spectra pre-processing, principal component analysis, and partial least-squares. Sample handling techniques (flow and sequential injection analysis) that include transport to spectroscopic sensors for ex-situ on-line monitoring are not covered in this review.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the monitoring of intracellular and extracellular macromolecules in bioprocesses share many intrinsic similarities to yeast and bacteria bioprocesses, which have been extensively reviewed together due to these similarities [20,21,29].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
In the citing paper
“Currently, there are few reviews of vibrational spectroscopy as it pertains to the microalgae industry [9,17-19]; however, these reviews do not take into account the technological progress and development of on-line/in-line vibrational spectroscopy implemented in bioprocess, pharmaceutical, and liquid and solid food industries [20-28]”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
In the citing paper
“There are numerous cases of in situ MIR applications, all of which use ATR-FTIR probes to acquire quantitative MIR spectra of a multitude of media components and bioproducts [20,21].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
In the citing paper
“MIR spectra relevant to the microalgal industry obtained in situ in yeast and bacterial bioreaction suspensions in 5 L to 15 L reactors include optical density, ammonium, phosphates, acetate, glucose, fructose, organic acids as well as several bioproducts [20,21].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
In the citing paper
“However, a promising mode of MIR for wet applications is attenuated total reflectance Fourier transform infrared (ATR-FTR), which has had growing applications in pharmaceutical, agro-food, and environmental sectors and can be used on-line/in-line in liquid media (see reviews by [20] and [21]).”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
In the citing paper
“NIR in vivo analysis of microalgae has only yet investigated biomass, lipids, and carotenoids (Fig. 2) but the potential use of high-selectivity on-line/in-line NIR in microalgae bioreactions is evidenced by its prolific use in other bioprocesses [20,21].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
In the citing paper
“Most applications of vibrational spectroscopy PAT require calibration and validation of chemometric models [21, 48,102] with the exception of some analytes, for example carotenoids measured through Raman [94].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
In the citing paper
“Another drawback of ATR-FTIR is that fiber optic materials with sufficient MIR transmission are limited and costly [80] and require very short fiber optic cables and may not be suitable for multiplexing [21] to monitor inhomogeneities across large scale photobioreactors.”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
In the citing paper
“On the other hand, Raman and NIR are more likely to be multiplexed with fiber optic conduits, each which can be up to a few meters long [21].”
From Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives (2018) · cites this paper as [21]
Citations
Cites
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084
Encyclopedia of Analytical Chemistry
Grochocki, W., Markuszewski, M., & Quirino, J. P. (2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,503
Infrared Spectroscopy: Fundamentals and Applications
Stuart, B. H. (2004) · Analytical Techniques in the Sciences · doi:10.1002/0470011149 · Cited by 4,427
Fuzzy clustering with a fuzzy covariance matrix
Gustafson, D. E., & Kessel, W. (1978) · IEEE Conference on Decision and Control including the Symposium on Adaptive Processes (CDC) · doi:10.1109/cdc.1978.268028 · Cited by 1,981
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2006) · Analytical Chemistry · doi:10.1021/ac060490z · Cited by 1,635
Handbook of Near-Infrared Analysis
Burns, D. A., & Ciurczak, E. W. (2001) · CRC Press eBooks · doi:10.1201/9781003042204 · Cited by 1,472
Multivariate SPC Charts for Monitoring Batch Processes
Nomikos, P., & MacGregor, J. F. (1995) · Technometrics · doi:10.1080/00401706.1995.10485888 · Cited by 1,430
A user-friendly guide to Multivariate Calibration and Classification
Næs, T., Isaksson, T., Fearn, T., & Davies, T. (2017) · doi:10.1255/978-1-906715-25-0 · Cited by 1,401
A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
Roggo, Y., Chalus, P., Maurer, L., Lema-Martinez, C., Edmond, A., & Jent, N. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.023 · Cited by 1,136
Flagged first, then by citations
Research works printed but not linked: 6
- Morris R (2010) How optical advances helped deliver the promise of miniature spectrometers. Spectroscopy 25:30–35
- Mark H (2000) In: Meyers RA (ed) Encyclopedia of analytical chemistry. John Wiley and Sons, Chichester
- Kourti T (2004) Process analytical technology and multivariate statistical process control. PAT J Proc Anal Technol 1:13–19
- Baylor LC, O’Rourke PE (2005) In: Bakeev KA (ed) Process analytical technology – spectroscopic tools and implementation strategies for the chemical and pharmaceutical industries. Blackwell, Oxford
- Bakeev KA (ed) (2005) Process analytical technology – spectroscopy tools and implementation strategies for the chemical and pharmaceutical industries. Blackwell, Oxford
- Hart JR, Golumbic C, Norris KH (1962) Determination of moisture content if seeds by near-infrared spectrophotometry of their methanol extracts. Cereal Chem 39:94–99
Cited by
Sorted by citations
Items 101–200 of 275
Assawajaruwan, S., Reinalter, J., & Hitzmann, B. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9823-2 · Cited by 19
Pontius, K., Junicke, H., Gernaey, K. V., & Bevilacqua, M. (2020) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-020-10604-0 · Cited by 19
Sousa, B. V., Silva, F., Reis, M. A. M., & Lourenço, N. D. (2021) · Biochemical Engineering Journal · doi:10.1016/j.bej.2021.108210 · Cited by 19
Self-citationRaman spectroscopy applied to online monitoring of a bioreactor: Tackling the limit of detection
Yang, N., Guerin, C., Kokanyan, N., & Perré, P. (2023) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2023.123343 · Cited by 18
Advances and opportunities in process analytical technologies for viral vector manufacturing
Sripada, S. A., Hosseini, M., Ramesh, S., Wang, J., Ritola, K., Menegatti, S., & Daniele, M. A.-A. (2024) · Biotechnology Advances · doi:10.1016/j.biotechadv.2024.108391 · Cited by 18
Propagation of measurement accuracy to biomass soft-sensor estimation and control quality
Steinwandter, V., Zahel, T., Sagmeister, P., & Herwig, C. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9711-9 · Cited by 18
Chen, X., Hu, R., Hu, L., Huang, Y., Shi, W., Wei, Q., & Li, Z. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00837 · Cited by 19
Biological Wastewater Treatment
Ahuja, M., Verma, V., Kaul, M., Kumar, L., & Kumar, S. (2024) · Water science and technology library · doi:10.1007/978-3-031-58331-5_1 · Cited by 18
Monitoring and Control of Bioreactor: Basic Concepts and Recent Advances
Gomes, J., Chopda, V., & Rathore, A. S. (2018) · doi:10.1002/9781119378341.ch6 · Cited by 18
Dan, A., Liu, B., Patil, U., Manuraj, B. N. M., Gandhi, R., Buchel, J., Chundawat, S. P. S., Guo, W., & Ramachandran, R. (2025) · Control Engineering Practice · doi:10.1016/j.conengprac.2024.106198 · Cited by 20
Ji, K., Yu, X., Chen, L., Wang, Y., Guo, Z., Chen, B., Li, Q., Li, Z., Hu, Z., Wang, G., et al. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.29040 · Cited by 17
Raman-Based Feedback Control of the Enzymatic Hydrolysis of Lactose
Hirsch, E., Pataki, H., Farkas, A., Bata, H., Vass, P., Fehér, C., Barta, Z., Párta, L., Csontos, I., Ballagi, A., et al. (2016) · Organic Process Research & Development · doi:10.1021/acs.oprd.6b00212 · Cited by 17
Müller, D. H., Flake, C., Brands, T., & Koß, H. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28424 · Cited by 18
He, Q., & Chen, H. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9077-4 · Cited by 17
Multi-Sensor Chip for Monitoring Key Parameters in Bioprocesses
Rusli, N. I., Vincentini, I. P., Ceyssens, F., & Kraft, M. D. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3094034 · Cited by 16
Zu, T. N. K., Liu, S., Gerlach, E. S., Germane, K. L., Servinsky, M. D., Mackie, D. M., & Sund, C. J. (2017) · Journal of Raman Spectroscopy · doi:10.1002/jrs.5264 · Cited by 16
Goldrick, S., Lovett, D., Montague, G. A., & Lennox, B. (2018) · Bioengineering · doi:10.3390/bioengineering5040079 · Cited by 16
Leme, J., Núñez, E. G. F., Parizotto, L. D. A., Chagas, W. A., dos Santos, E. S., Caricati, A. T. P., de Rezende, A. G., da Costa, B. L. V., Monteiro, D. C. V., Boldorini, V. L. L., et al. (2013) · Biotechnology Progress · doi:10.1002/btpr.1847 · Cited by 16
Veloso, I. I. K., Rodrigues, K. C. S., Ribeiro, M. P. D. A., Cruz, A. J. G., & Junior, A. C. B. (2020) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c03717 · Cited by 15
Navato, A. P., & Mueller, A. V. (2021) · Frontiers in Water · doi:10.3389/frwa.2021.734361 · Cited by 17
Sagmeister, P., Langemann, T., Wechselberger, P., Meitz, A., & Herwig, C. (2013) · Microbial Cell Factories · doi:10.1186/1475-2859-12-94 · Cited by 15
Luoma, P., Golabgir, A., Brandstetter, M., Kasberger, J., & Herwig, C. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9918-9 · Cited by 15
Koch, C., Posch, A. E., Herwig, C., & Lendl, B. (2016) · Applied Spectroscopy · doi:10.1177/0003702816662618 · Cited by 16
Advances in Ultraviolet and Visible Light Spectroscopy for Food Authenticity Testing
Martelo-Vidal, M. J., & Vázquez, M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100220-9.00003-5 · Cited by 15
Zhou, Y., Mao, J., Liu, T., Zhou, W., & Chen, Z. (2017) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2017.04.002 · Cited by 15
Geinitz, B., Rehmann, L., Büchs, J., & Regestein, L. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27256 · Cited by 14
Zalai, D., Kopp, J., Kozma, B., Küchler, M., Herwig, C., & Kager, J. (2020) · Drug Discovery Today : Technologies · doi:10.1016/j.ddtec.2021.04.001 · Cited by 13
Strani, L., Vitale, R., Tanzilli, D., Bonacini, F., Perolo, A., Mantovani, E., Ferrando, A., & Cocchi, M. (2022) · Sensors · doi:10.3390/s22041436 · Cited by 14
Vann, L., & Sheppard, J. (2017) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-017-1984-2 · Cited by 14
Brunner, M., Brosig, P., Losing, M., Kunzelmann, M., Calvet, A., Stiefel, F., Bechmann, J., Unsoeld, A., & Schaub, J. (2019) · Engineering in Life Sciences · doi:10.1002/elsc.201900050 · Cited by 14
Yang, N., Guerin, C., Kokanyan, N., & Perré, P. (2024) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2024.10.007 · Cited by 13
Sagmeister, P., Jazini, M., Klein, J., & Herwig, C. (2014) · Wiley eBooks · doi:10.1002/9783527683321.ch01 · Cited by 12
Karnachoriti, M., Chatzipetrou, M., Touloupakis, E., Kontos, A., & Zergioti, I. (2025) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6841 · Cited by 8
Chandrasekaran, K., Chandrasekaran, K., Jayaraman, G., & Bhatt, N. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.165116 · Cited by 12
Near-infrared spectroscopy in upstream bioprocesses
Hoehse, M., Alves-Rausch, J., Prediger, A., Roch, P., & Grimm, C. (2015) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.15.1 · Cited by 12
Towards Process Spectroscopy in Complex Fermentation Samples and Mixtures
Paul, A., Carl, P., Westad, F., Voss, J., & Maiwald, M. (2016) · Chemie Ingenieur Technik · doi:10.1002/cite.201500118 · Cited by 12
Zabadaj, M., Ufnalska, I., Chreptowicz, K., Mierzejewska, J., Wróblewski, W., & Ciosek, P. (2017) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2017.05.003 · Cited by 12
Rapid monitoring of beer-quality attributes based on UV-Vis spectral data
de Oliveira, H. C., Filho, J. C. E. D. C., Rocha, J. C., & Núñez, E. G. F. (2017) · International Journal of Food Properties · doi:10.1080/10942912.2017.1352602 · Cited by 12
Brognaux, A., Bugge, J., Schwartz, F. H., Thonart, P., Telek, S., & Delvigne, F. (2013) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-013-1271-9 · Cited by 12
Sensors for Disposable Bioreactor Systems
Steinwedel, T., Dahlmann, K., Solle, D., Scheper, T. H., Reardon, K. F., & Lammers, F. (2019) · Wiley eBooks · doi:10.1002/9781119477891.ch6 · Cited by 11
Data-driven neural networks for biological wastewater resource recovery: Development and challenges
Xu, R., Cao, J., Luo, J., Ni, B., Fang, F., Liu, W., & Wang, P. (2024) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2024.143781 · Cited by 13
Production of Protein Therapeutics in the Quality by Design (QbD) Paradigm
Rathore, A. S., & Singh, S. K. (2016) · Topics in medicinal chemistry · doi:10.1007/7355_2015_5004 · Cited by 11
Online Analysis for Industrial Bioprocesses
Veloso, A. C. A., & Ferreira, E. C. (2016) · Elsevier eBooks · doi:10.1016/b978-0-444-63663-8.00023-9 · Cited by 11
Ito, S., Barchi, A. C., Escaramboni, B., Neto, P. D. O., Herculano, R. D., Borges, F. A., Miranda, M. C. R., & Núñez, E. G. F. (2017) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.5271 · Cited by 11
Assawajaruwan, S., Eckard, P., & Hitzmann, B. (2017) · Process Biochemistry · doi:10.1016/j.procbio.2017.05.007 · Cited by 11
Xu, X., Farnós, O., Paes, B. C. M. F., Nesdoly, S., & Kamen, A. (2024) · Biotechnology and Bioengineering · doi:10.1002/bit.28712 · Cited by 10
Klaverdijk, M., Ottens, M., & Klijn, M. E. (2025) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-025-05768-5 · Cited by 11
Aleixandre-Tudó, J. L., & du Toit, W. (2019) · LWT · doi:10.1016/j.lwt.2019.05.020 · Cited by 10
Franca, R. D. G., Carvalho, V. C. F., Fradinho, J. C., Reis, M. A. M., & Lourenço, N. D. (2021) · Applied Sciences · doi:10.3390/app11146600 · Cited by 10
Self-citationSantos, M. V., Rodrigues, K. C. S., Veloso, I. I. K., Junior, A. C. B., & Cruz, A. J. G. (2022) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.2c00325 · Cited by 10
Berg, C., Ihling, N., Finger, M., Paquet‐Durand, O., Hitzmann, B., & Büchs, J. (2022) · Bioengineering · doi:10.3390/bioengineering9090438 · Cited by 10
Jarusintanakorn, S., Phechkrajang, C. M., Khongkaew, P., Mastrobattista, E., & Yamabhai, M. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03549-4 · Cited by 10
Jiang, T., Kwofie, F., Attanasio, N., Haas, M., Higgins, J. D., & Kosanam, H. (2024) · The AAPS Journal · doi:10.1208/s12248-024-00973-z · Cited by 11
Monitoring of an antigen manufacturing process
Zavatti, V., Budman, H. M., Legge, R. L., & Tamer, M. I. (2016) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-016-1565-1 · Cited by 9
Doppler, P., Gasser, C., Kriechbaum, R., Ferizi, A., & Oliver Spadiut, A. (2021) · Bioengineering · doi:10.3390/bioengineering8090129 · Cited by 10
Dillen, A., & Lammertyn, J. (2022) · The Analyst · doi:10.1039/d1an02308j · Cited by 9
Narayana, S. K., Christensen, L., Skov, T., & van den Berg, F. W. J. (2019) · Applied Spectroscopy · doi:10.1177/0003702819848486 · Cited by 9
Nachtergaele, P., Thybaut, J. W., Meester, S. D., Drijvers, D., Saeys, W., & Dewulf, J. P. (2020) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c00515 · Cited by 9
High sensitivity static Fourier transform spectrometer
Frassetto, F., Cocola, L., Zuppella, P., Deppo, V. D., & Poletto, L. (2021) · Optics Express · doi:10.1364/oe.422645 · Cited by 9
Kaneko, H., Kono, S., Nojima, A., & Kambayashi, T. (2021) · Analytical Science Advances · doi:10.1002/ansa.202000177 · Cited by 9
Gerstl, M. P., Joksch, M., & Fafilek, G. (2015) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2015.01.009 · Cited by 9
Lambrecht, K., Nieuwoudt, H. H., du Toit, W., & Aleixandre-Tudó, J. L. (2022) · Fermentation · doi:10.3390/fermentation8050231 · Cited by 8
Integration of Fluorescence Spectroscopy into a Photobioreactor for the Monitoring of Cyanobacteria
García, B. G., Fernández-Manteca, M. G., Gómez-Galdós, C., Álvarez, S. D., Monteoliva, A., Higuera, J. M. L., Algorri, J. F., Ocampo-Sosa, A. A., Cobo, L. R., & Cobo, A. (2025) · Biosensors · doi:10.3390/bios15030128 · Cited by 8
Spectroscopy Based In-Line Monitoring and Control of Food Quality and Safety
Bhatt, P., Mutturi, S., & Thakur, M. S. (2023) · Food engineering series · doi:10.1007/978-3-031-30683-9_12 · Cited by 8
Comparing machine learning methods on Raman spectra from eight different spectrometers
Lange, C., Borisyak, M., Kögler, M., Born, S., Ziehe, A., Neubauer, P. B., & Bournazou, M. N. C. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.125861 · Cited by 8
Chopda, V., Pathak, M., Batra, J., Gomes, J., & Rathore, A. S. (2016) · Engineering in Life Sciences · doi:10.1002/elsc.201600155 · Cited by 8
Corro‐Herrera, V. A., Rodríguez, J. G., Hayward‐Jones, P. M., Barradas-Dermitz, D. M., Gschaedler, A., & Aguilar‐Uscanga, M. G. (2018) · Engineering in Life Sciences · doi:10.1002/elsc.201700189 · Cited by 8
Thiel, M., Sauwen, N., Khamiakova, T., Maes, T., & Govaerts, B. B. (2021) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2021.104273 · Cited by 8
On-line identification of fermentation processes for ethanol production
Câmara, M. M., Soares, R. M., Feital, T. D. S., Naomi, P., Oki, S., Thevelein, J. M., Amaral, M., & Pinto, J. C. (2017) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-017-1762-6 · Cited by 8
Model-Based Process Optimization for the Production of Macrolactin D by Paenibacillus polymyxa
Krämer, D., Wilms, T., & King, R. (2020) · Processes · doi:10.3390/pr8070752 · Cited by 8
PCA and PLS Analysis of Lanthanides Using Absorbance and Single-Beam Visible Spectra
Lackey, H. E., Nelson, G. L., Felmy, H. M., Guo, X., Bryan, S. A., & Lines, A. M. (2024) · ACS Omega · doi:10.1021/acsomega.4c02202 · Cited by 7
AutoML‐Driven Soft Sensors for Real‐Time Monitoring of Amino Acids in Mammalian Perfusion Cultures
Kim, S. H., Lee, M., Kim, D., Yoon, S., & Lee, D. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70036 · Cited by 7
Methodical Aspects of Biogas Production in Small-Volume Bioreactors in Laboratory Investigations
Kasprzycka, A., & Kuna, J. (2018) · Energies · doi:10.3390/en11061378 · Cited by 7
Schwamb, S., Puskeiler, R., & Wiedemann, P. (2014) · Cell engineering · doi:10.1007/978-3-319-10320-4_7 · Cited by 7
Standard Instruments for Bioprocess Analysis and Control
Rodríguez‐Durán, L. V., Torres‐Mancera, M. T., Trujillo‐Roldán, M. A., Valdez‐Cruz, N. A., Favela‐Torres, E., & Saucedo‐Castañeda, G. (2016) · Elsevier eBooks · doi:10.1016/b978-0-444-63663-8.00020-3 · Cited by 7
Simão, V. A., Evangelista-Ribeiro, C. P., Brand, H., Lagass-Pereira, L., Marques, L. F., Aoki, P. H. B., Antunes, R. N. S., Tonso, A., & Ribeiro‐Paes, J. T. (2019) · Biologicals · doi:10.1016/j.biologicals.2019.08.006 · Cited by 7
A Setup for Automatic Raman Measurements in High‐Throughput Experimentation
Lange, C., Seidel, S., Altmann, M., Stors, D., Kemmer, A., Cai, L., Born, S., Neubauer, P. B., & Bournazou, M. N. C. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70006 · Cited by 6
Breen, L., Flynn, J., Bergin, A., Flampouri, E., & Butler, M. (2024) · Biotechnology Progress · doi:10.1002/btpr.3469 · Cited by 6
Princz, S., Wenzel, U., Miller, R., & Heßling, M. (2014) · Journal of Applied Spectroscopy · doi:10.1007/s10812-014-0017-4 · Cited by 6
Spectroscopic Analysis of Wheat Fractions and Reconstituted Whole Wheat Mixtures by 1H‐NMR and NIR
Ramakrishnan, V., Ridge, C. D., Harnly, J. M., Mazzola, E. P., & Luthria, D. L. (2016) · Cereal Chemistry · doi:10.1094/cchem-06-16-0177-r · Cited by 6
Henstock, J. R., & Haj, A. J. E. (2016) · Mechanobiology · doi:10.1002/9781118966174.ch18 · Cited by 6
Deep learning for Raman spectroscopy: Benchmarking models for upstream bioprocess monitoring
Lange, C., Altmann, M., Stors, D., Seidel, S., Moynahan, K., Cai, L., Born, S., Neubauer, P., & Bournazou, M. N. C. (2025) · Measurement · doi:10.1016/j.measurement.2025.118884 · Cited by 6
Gröger, M., Lange, M., Rennert, K., Kaschowitz, T., Plettenberg, H., Hoffmann, M., & Mosig, A. S. (2016) · Engineering in Life Sciences · doi:10.1002/elsc.201600162 · Cited by 5
Perić, M., Savanović, M. M., Bilić, A., Armaković, S. J., & Armaković, S. (2024) · Journal of the Indian Chemical Society · doi:10.1016/j.jics.2024.101173 · Cited by 5
Sarraguça, J. M. G., Lima, C., Machado, F., Lopes, J. A., Almeida, A. A., Fernandes, L. M., Magalhães, T., & Santos, A. (2016) · The Analyst · doi:10.1039/c6an00247a · Cited by 5
Self-citationShimada, R., Nakamura, T., & Ozawa, T. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201960028 · Cited by 5
Single Bacteria Movement Tracking by Online Microscopy – A Proof of Concept Study
Ziegler, A., Schock‐Kusch, D., Bopp, D., Dounia, S., Rädle, M., & Ståhl, U. (2015) · PLoS ONE · doi:10.1371/journal.pone.0122531 · Cited by 5
Tecnologia de bioprocesso para produção de alimentos funcionais.
de Sousa, R. D. C. P., dos Santos, D. C., Neves, L. C., & Chagas, E. A. (2013) · Revista Agro mbiente On-line · doi:10.18227/1982-8470ragro.v7i3.1240 · Cited by 5
Use of Near-Infrared Spectroscopy for Coffee Beans Quality Assessment
Páscoa, R. N. M. J., Sarraguça, M. C., Magalhães, L. M., Santos, J. R., Rangel, A. O. S. S., & Lopes, J. A. (2014) · Coffee in Health and Disease Prevention · doi:10.1016/b978-0-12-409517-5.00103-0 · Cited by 5
Self-citationLebanov, L., Mikhail, I. E., & Paull, B. (2024) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2024.100191 · Cited by 4
Boateng, B. O., & Ryder, A. G. (2024) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2024.10.002 · Cited by 4
Zarin, A. S., Chakraborty, A. L., & Upadhyay, A. (2017) · Optics Letters · doi:10.1364/ol.42.002138 · Cited by 4
Impact of oxidative stress on protein production by Bordetella pertussis for vaccine production
Zavatti, V., Budman, H. M., Legge, R. L., & Tamer, M. I. (2019) · Biochemical Engineering Journal · doi:10.1016/j.bej.2019.107359 · Cited by 4
Sigcau, K., van Rooyen, I. L., Hoek, Z., Brink, H. G., & Nicol, W. (2022) · Plants · doi:10.3390/plants11111456 · Cited by 4
Edwiges, T., Roda‐Serrat, M. C., Segovia‐Hernández, J. G., Sánchez‐Ramírez, E., Tronci, S., & Errico, M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824117-2.00004-1 · Cited by 4
Cao, J., Gorecki, J., Dale, R., Redwood-Sawyerr, C., Kontoravdi, C., Polizzi, K. M., Rowlands, C. J., & Dehghani, H. (2024) · Biomedical Optics Express · doi:10.1364/boe.529884 · Cited by 4
Vier, D., Wambach, S., Schünemann, V., & Gollmer, K.-U. (2017) · Bioengineering · doi:10.3390/bioengineering4010009 · Cited by 4
Li, Z., Zhang, X., & Karanassios, V. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2050326 · Cited by 4
Multivariate Modeling for Bioreactor Monitoring and Control
Glassey, J. (2016) · doi:10.1002/9783527683369.ch13 · Cited by 4
Halfway to Automated Feeding of Chinese Hamster Ovary Cells
Tomažič, S., & Škrjanc, I. (2023) · Sensors · doi:10.3390/s23146618 · Cited by 3
Metadata
- Authors
- Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M.
- Affiliations
- Institute for Biotechnology and Bioengineering (PT)
- Universidade do Porto (PT)
- Corresponding author
- Lourenço, N. D.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2012-05-30
- Volume
- 404
- Issue
- 4
- Pages
- 1211-1237
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2057328981
- Cited by
- 275
- References
- 123
- Citations by year
- 2026: 10 · 2025: 20 · 2024: 23 · 2023: 13 · 2022: 20 · 2021: 23 · 2020: 22 · 2019: 23 · 2018: 21 · 2017: 29 · 2016: 28 · 2015: 17 · 2014: 16 · 2013: 10
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Keywords
- bioreactor monitoring, bioprocess monitoring, in situ monitoring, fiber optic sensors, UV-Vis spectroscopy, near-infrared spectroscopy, mid-infrared spectroscopy, Raman spectroscopy, fluorescence spectroscopy, chemometrics, principal component analysis, partial least squares, wavelength selection, microbial cultivation, real-time process control
- MeSH terms
- Bacteria, Biotechnology, Spectrum Analysis, Bioreactors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review