CoChat

Probeless non-invasive near-infrared spectroscopic bioprocess monitoring using microspectrometer technology

Zimmerleiter, Robert, Kager, Julian, Nikzad-Langerodi, Ramin, Berezhinskiy, Vladimir, Westad, Frank, Herwig, Christoph, Brandstetter, Markus · 2020 · Analytical and Bioanalytical Chemistry
Cited by 33

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Real-time measurements and adjustments of critical process parameters are essential for the precise control of fermentation processes and thus for increasing both quality and yield of the desired product. However, the measurement of some crucial process parameters such as biomass, product, and product precursor concentrations usually requires time-consuming offline laboratory analysis. In this work, we demonstrate the in-line monitoring of biomass, penicillin (PEN), and phenoxyacetic acid (POX) in a Penicillium chrysogenum fed-batch fermentation process using low-cost microspectrometer technology operating in the near-infrared (NIR). In particular, NIR reflection spectra were taken directly through the glass wall of the bioreactor, which eliminates the need for an expensive NIR immersion probe. Furthermore, the risk of contaminations in the reactor is significantly reduced, as no direct contact with the investigated medium is required. NIR spectra were acquired using two sensor modules covering the spectral ranges 1350–1650 nm and 1550–1950 nm. Based on offline reference analytics, partial least squares (PLS) regression models were established for biomass, PEN, and POX either using data from both sensors separately or jointly. The established PLS models were tested on an independent validation fed-batch experiment. Root mean squared errors of prediction (RMSEP) were 1.61 g/L, 1.66 g/L, and 0.67 g/L for biomass, PEN, and POX, respectively, which can be considered an acceptable accuracy comparable with previously published results using standard process spectrometers with immersion probes. Altogether, the presented results underpin the potential of low-cost microspectrometer technology in real-time bioprocess monitoring applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00216-019-02227-w

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 20

  1. Vaidyanathan S, Macaloney G, Vaughan J, et al. Monitoring of submerged bioprocesses. Crit Rev Biotechnol. 1999;19:277–316. https://doi.org/10.1080/0738-859991229161. · DOI · Paper page
  2. Kiviharju K, Salonen K, Moilanen U, et al. On-line biomass measurements in bioreactor cultivations: comparison study of two on-line probes. J Ind Microbiol Biotechnol. 2007;34:561–6. https://doi.org/10.1007/s10295-007-0233-5. · DOI · Paper page
  3. November EJ, Van Impe JF. Evaluation of on-line viable biomass measurements during fermentations of Candida utilis. Bioprocess Eng. 2000;23:473–7. https://doi.org/10.1007/s004499900179. · DOI
  4. Resa P, Elvira L, De Espinosa FM. Concentration control in alcoholic fermentation processes from ultrasonic velocity measurements. Food Res Int. 2004;37:587–94. https://doi.org/10.1016/j.foodres.2003.12.012. · doi:10.1016/j.foodres.2003.12.012
  5. Brecker L, Weber H, Griengl H, Ribbons DW. In situ proton-NMR analyses of Escherichia coli HB101 fermentations in 1H2O and in D2O. Microbiology. 1999;145:3389–97. https://doi.org/10.1099/00221287-145-12-3389. · DOI
  6. Noui L, Hill J, Keay PJ, et al. Development of a high resolution UV spectrophotometer for at-line monitoring of bioprocesses. Chem Eng Process. 2002;41:107–14. https://doi.org/10.1016/S0255-2701(01)00122-2. · DOI
  7. Ávila TC, Poppi RJ, Lunardi I, et al. Raman spectroscopy and chemometrics for on-line control of glucose fermentation by Saccharomyces cerevisiae. Biotechnol Prog. 2012;28:1598–604. https://doi.org/10.1002/btpr.1615. · DOI · Paper page
  8. Koch C, Posch AE, Goicoechea HC, et al. Multi-analyte quantification in bioprocesses by Fourier-transform-infrared spectroscopy by partial least squares regression and multivariate curve resolution. Anal Chim Acta. 2014;807:103–10. https://doi.org/10.1016/J.ACA.2013.10.042. · DOI
  9. Arnold SA, Gaensakoo R, Harvey LM, McNeil B. Use of at-line and in-situ near-infrared spectroscopy to monitor biomass in an industrial fed-batch Escherichia coli process. Biotechnol Bioeng. 2002;80:405–13. https://doi.org/10.1002/bit.10383. · DOI · Paper page
  10. Ebermann M, Neumann N, Hiller K, et al (2016) Tunable MEMS Fabry-Pérot filters for infrared microspectrometers: a review. In: Piyawattanametha W, Park Y-H (eds). International Society for Optics and Photonics, p 97600H. · DOI
  11. Antila J, Tuohiniemi M, Rissanen A, et al. MEMS- and MOEMS-based near-infrared spectrometers. In: Encyclopedia of analytical chemistry. Chichester: John Wiley & Sons, Ltd; 2014. p. 1–36.
  12. Erfan M, Sabry YM, Sakr M, et al. On-chip micro–electro–mechanical system Fourier transform infrared (MEMS FT-IR) spectrometer-based gas sensing. Appl Spectrosc. 2016;70:897–904. https://doi.org/10.1177/0003702816638295. · DOI
  13. Wiedemair V, Mair D, Held C, Huck CW. Investigations into the use of handheld near-infrared spectrometer and novel semi-automated data analysis for the determination of protein content in different cultivars of Panicum miliaceum L. Talanta. 2019;205:546–53. · DOI
  14. Kilgus J, Langer G, Duswald K, et al. Diffraction limited mid-infrared reflectance microspectroscopy with a supercontinuum laser. Opt Express. 2018;26:30644. https://doi.org/10.1364/OE.26.030644. · doi:10.1364/oe.26.030644
  15. Gattinger P, Kilgus J, Zorin I, et al. Broadband near-infrared hyperspectral single pixel imaging for chemical characterization. Opt Express. 2019;27:12666. https://doi.org/10.1364/OE.27.012666. · DOI
  16. Posch AE, Herwig C. Physiological description of multivariate interdependencies between process parameters, morphology and physiology during fed-batch penicillin production. Biotechnol Prog. 2014;30:689–99. https://doi.org/10.1002/btpr.1901. · DOI
  17. Luoma P, Golabgir A, Brandstetter M, et al. Workflow for multi-analyte bioprocess monitoring demonstrated on inline NIR spectroscopy of P. chrysogenum fermentation. Anal Bioanal Chem. 2017;409:797–805. https://doi.org/10.1007/s00216-016-9918-9. · DOI
  18. Burns DA, Ciurczak EW. Handbook of near-infrared analysis: CRC Press; 2008. · DOI · Paper page
  19. Luoma P, Natschläger T, Malli B, et al. Additive partial least squares for efficient modelling of independent variance sources demonstrated on practical case studies. Anal Chim Acta. 2018;1007:10–5. · doi:10.1016/j.aca.2017.12.027
  20. Nikzad-Langerodi R, Zellinger W, Lughofer E, Saminger-Platz S. Domain-invariant partial least squares regression. Anal Chem. 2018;90:6693–701. https://doi.org/10.1021/acs.analchem.8b00498. · DOI

Cited by

See all 33

Metadata

Authors
Zimmerleiter, R., Kager, J., Nikzad-Langerodi, R., Berezhinskiy, V., Westad, F., Herwig, C., & Brandstetter, M.
Venue
Analytical and Bioanalytical Chemistry
Published
2019-12-04
Volume
412
Issue
9
Pages
2103-2109
ISSN
  • 1618-2642
  • 1618-2650
Cited by
33
References
5
Language
en
Licence
Funders
  • Österreichische Forschungsförderungsgesellschaft (871974)
  • Austrian Competence Centre for Feed and Food Quality, Safety and Innovation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Probeless non-invasive near-infrared spectroscopic bioprocess monitoring using microspectrometer technology. https://app.cochat.ai/papers/10.1007/s00216-019-02227-w
The paper
Zimmerleiter, R., Kager, J., Nikzad-Langerodi, R., Berezhinskiy, V., Westad, F., Herwig, C., & Brandstetter, M. (2020). Probeless non-invasive near-infrared spectroscopic bioprocess monitoring using microspectrometer technology. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-019-02227-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.