Integrated prediction of lesion-specific ischaemia from quantitative coronary CT angiography using machine learning: a multicentre study
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: We aimed to investigate if lesion-specific ischaemia by invasive fractional flow reserve (FFR) can be predicted by an integrated machine learning (ML) ischaemia risk score from quantitative plaque measures from coronary computed tomography angiography (CTA). METHODS: In a multicentre trial of 254 patients, CTA and invasive coronary angiography were performed, with FFR in 484 vessels. CTA data sets were analysed by semi-automated software to quantify stenosis and non-calcified (NCP), low-density NCP (LD-NCP, < 30 HU), calcified and total plaque volumes, contrast density difference (CDD, maximum difference in luminal attenuation per unit area) and plaque length. ML integration included automated feature selection and model building from quantitative CTA with a boosted ensemble algorithm, and tenfold stratified cross-validation. RESULTS: Eighty patients had ischaemia by FFR (FFR ≤ 0.80) in 100 vessels. Information gain for predicting ischaemia was highest for CDD (0.172), followed by LD-NCP (0.125), NCP (0.097), and total plaque volumes (0.092). ML exhibited higher area-under-the-curve (0.84) than individual CTA measures, including stenosis (0.76), LD-NCP volume (0.77), total plaque volume (0.74) and pre-test likelihood of coronary artery disease (CAD) (0.63); p < 0.006. CONCLUSIONS: Integrated ML ischaemia risk score improved the prediction of lesion-specific ischaemia by invasive FFR, over stenosis, plaque measures and pre-test likelihood of CAD. KEY POINTS: • Integrated ischaemia risk score improved prediction of ischaemia over quantitative plaque measures • Integrated ischaemia risk score showed higher prediction of ischaemia than standard approach • Contrast density difference had the highest information gain to identify lesion-specific ischaemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Mining: Practical Machine Learning Tools and Techniques
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-19715-5 · Cited by 25,437
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
The WEKA data mining software: an update
Hall, M., Frank, E., Holmes, G., Pfahringer, B., Reutemann, P., & Witten, I. H. (2009) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1656274.1656278 · Cited by 17,750 · cited 2×
“Prediction of lesion-specific ischaemia was performed by an ensemble classification approach (Bboosting^), employing the iterative, additive LogitBoost algorithm using decision stumps (single-node decision trees) for each feature-selected parameter [29, 33].”
MethodFriedman, J., Hastie, T., & Tibshirani, R. (2000) · The Annals of Statistics · doi:10.1214/aos/1016218223 · Cited by 6,884 · cited 1×
“Prediction of lesion-specific ischaemia was performed by an ensemble classification approach (Bboosting^), employing the iterative, additive LogitBoost algorithm using decision stumps (single-node decision trees) for each feature-selected parameter [29, 33].”
Method2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Self-citationFractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260 · cited 1×
“Revascularization strategies guided by lesion-specific ischaemia, assessed by invasive fractional flow reserve (FFR), have been shown to improve patient outcomes [11, 12].”
MethodPredicting the future - big data, machine learning, and clinical medicine
Obermeyer, Z., & Emanuel, E. J. (2016) · New England Journal of Medicine · doi:10.1056/nejmp1606181 · Cited by 3,652 · cited 1×
“In the future, we would expect big data and machine learning algorithms to improve diagnostic accuracy and help the imaging physician find the right answer for the patients, whose Blives and medical histories shape the algorithms^ [46].”
BackgroundMulti-Interval Discretization of Continuous-Valued Attributes for Classification Learning
Fayyad, U. M., & Irani, K. B. (1993) · International Joint Conference on Artificial Intelligence · Cited by 3,534
Deo, R. C. (2015) · Circulation · doi:10.1161/circulationaha.115.001593 · Cited by 3,466
Budoff, M. J., Dowe, D., Jollis, J. G., Gitter, M., Sutherland, J., Halamert, E., Scherer, M., Bellinger, R., Martin, A., Benton, R., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.031 · Cited by 2,125
Diagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Nørgaard, B. L., Leipsic, J., Gaur, S., Seneviratne, S., Ko, B. S., Ito, H., Jensen, J. M., Mauri, L., De Bruyne, B., Bezerra, H., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.11.043 · Cited by 1,498 · cited 5×
“Exclusion criteria included prior stent implantation or coronary bypass surgery, contraindications to beta-blockers, nitrates or adenosine, suspicion of acute coronary syndrome, significant arrhythmia and body mass index greater than 35 kg/m(2) [21].”
BackgroundMethodInfluentialSelf-citationMotoyama, S., Sarai, M., Harigaya, H., Anno, H., Inoue, K., Hara, T., Naruse, H., Ishii, J., Hishida, H., Wong, N. D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.068 · Cited by 1,433 · cited 1×
“Low-density non-calcified plaque was defined as noncalcified plaque below a preset low-density threshold (30 HU) [26].”
BackgroundPrediction error estimation: a comparison of resampling methods
Molinaro, A. M., Simon, R., & Pfeiffer, R. M. (2005) · Bioinformatics · doi:10.1093/bioinformatics/bti499 · Cited by 1,339 · cited 2×
“Tenfold cross-validation has been shown to have smaller bias for discriminant analysis than the traditional split-sample approach (test and validation) [35].”
MethodKoo, B.-K., Erglis, A., Doh, J.-H., Daniels, D. V., Jegere, S., Kim, H.-S., Dunning, A., DeFrance, T., Lansky, A., Leipsic, J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.066 · Cited by 1,282
Benchmarking attribute selection techniques for discrete class data mining
Hall, M. A., & Holmes, G. (2003) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2003.1245283 · Cited by 1,232 · cited 1×
“Feature selection was performed on all patient and quantitative CTA measures using a method known as ‘information gain attribute ranking’ [19, 31], using stratified tenfold cross-validation.”
MethodDiagnostic Accuracy of Fractional Flow Reserve From Anatomic CT Angiography
Min, J. K., Leipsic, J., Pencina, M. J., Berman, D. S., Koo, B.-K., van Mieghem, C., Erglis, A., Lin, F. Y., Dunning, A. M., Apruzzese, P., et al. (2012) · JAMA · doi:10.1001/2012.jama.11274 · Cited by 1,162 · cited 1×
“The performance of noninvasive FFR, derived from standard CTA on the basis of computational fluid dynamicsbased methods from CTA (FFRCT), has been reported to be superior to CTA anatomical interpretation in prospective multicentre studies [21, 41, 42].”
MethodSelf-citationPijls, N. H. J., Fearon, W. F., Tonino, P. A. L., Siebert, U., Ikeno, F., Bornschein, B., van't Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.012 · Cited by 1,158 · cited 1×
“Revascularization strategies guided by lesion-specific ischaemia, assessed by invasive fractional flow reserve (FFR), have been shown to improve patient outcomes [11, 12].”
MethodLeipsic, J., Abbara, S., Achenbach, S., Cury, R., Earls, J. P., Mancini, G. J., Nieman, K., Pontone, G., & Raff, G. L. (2014) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2014.07.003 · Cited by 1,072
Self-citationAchenbach, S., Moselewski, F., Ropers, D., Ferencik, M., Hoffmann, U., MacNeill, B., Pohle, K., Baum, U., Anders, K., Jang, I.-K., et al. (2004) · Circulation · doi:10.1161/01.cir.0000111517.69230.0f · Cited by 831
Self-citationLeber, A. W., Becker, A., Knez, A., von Ziegler, F., Sirol, M., Nikolaou, K., Ohnesorge, B., Fayad, Z. A., Becker, C. R., Reiser, M., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.058 · Cited by 711
Motwani, M., Dey, D., Berman, D. S., Germano, G., Achenbach, S., Al-Mallah, M. H., Andreini, D., Budoff, M. J., Cademartiri, F., Callister, T. Q., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw188 · Cited by 692 · cited 7×
“Machine learning integration involved automated feature selection by information gain ranking, model building with a boosted ensemble algorithm and tenfold stratified cross-validation for the entire method [19].”
BackgroundMethodInfluentialSelf-citationLeber, A. W., Knez, A., Becker, A., Becker, C., von Ziegler, F., Nikolaou, K., Rist, C., Reiser, M., White, C., Steinbeck, G., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.059 · Cited by 662
Cardiovascular Event Prediction by Machine Learning: The Multi-Ethnic Study of Atherosclerosis
Ambale-Venkatesh, B., Yang, X., Wu, C. O., Liu, K., Hundley, W. G., McClelland, R., Gomes, A. S., Folsom, A. R., Shea, S., Guallar, E., et al. (2017) · Circulation Research · doi:10.1161/circresaha.117.311312 · Cited by 639 · cited 1×
“Recently machine learning applied to medical imaging was shown to improve diagnostic accuracy [17, 18] and prognostic outcomes [19, 20].”
BackgroundInterpreting Incremental Value of Markers Added to Risk Prediction Models
Pencina, M. J., D'Agostino, R. B., Pencina, K. M., Janssens, A. C. J. W., & Greenland, P. (2012) · American Journal of Epidemiology · doi:10.1093/aje/kws207 · Cited by 506 · cited 1×
“discrimination over a set of existing predictors [37].”
BackgroundAchenbach, S., Ropers, D., Hoffmann, U., MacNeill, B., Baum, U., Pohle, K., Brady, T. J., Pomerantsev, E., Ludwig, J., Flachskampf, F. A., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.09.053 · Cited by 408 · cited 1×
“Remodelling index was determined as the ratio of maximum vessel area to that at the proximal normal reference point [7].”
BackgroundSelf-citationItu, L., Rapaka, S., Passerini, T., Georgescu, B., Schwemmer, C., Schoebinger, M., Flohr, T., Sharma, P., & Comaniciu, D. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00752.2015 · Cited by 406
Meijboom, W. B., van Mieghem, C. A. G., Mollet, N. R., Pugliese, F., Weustink, A. C., van Pelt, N., Cademartiri, F., Nieman, K., Boersma, E., de Jaegere, P., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.007 · Cited by 370
Montalescot, G., Rangé, G., Belle, L., Pouillot, C., Boueri, Z., Cayla, G., BELLE, E. V., Silvain, J., Vicaut, É., & Collet, J. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht310.p4876 · Cited by 349
Park, H., Heo, R., Hartaigh, B. Ó., Cho, I., Gransar, H., Nakazato, R., Leipsic, J. A., Mancini, G. B. J., Koo, B., Otake, H., et al. (2015) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2014.11.002 · Cited by 310 · cited 2×
“It has been shown that plaque assessment from CTA adds significantly to stenosis assessment for the identification of lesion-specific ischaemia [38, 39].”
BackgroundResultSelf-citationGaur, S., Øvrehus, K. A., Dey, D., Leipsic, J., Bøtker, H. E., Jensen, J. M., Narula, J., Ahmadi, A., Achenbach, S., Ko, B. S., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv690 · Cited by 292
Self-citationCoenen, A., Lubbers, M. M., Kurata, A., Kono, A., Dedic, A., Chelu, R. G., Dijkshoorn, M. L., Gijsen, F. J., Ouhlous, M., van Geuns, R.-J. M., et al. (2015) · Radiology · doi:10.1148/radiol.14140992 · Cited by 264 · cited 1×
“Onsite FFRCT using a reduced-order computational fluid dynamics computation on a separate workstation has also been reported [43].”
MethodPundziute, G., Schuijf, J. D., Jukema, J. W., Decramer, I., Sarno, G., Vanhoenacker, P. K., Boersma, E., Reiber, J. H. C., Schalij, M. J., Wijns, W., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn356 · Cited by 232
Dey, D., Schepis, T., Marwan, M., Slomka, P. J., Berman, D. S., & Achenbach, S. (2010) · Radiology · doi:10.1148/radiol.10100681 · Cited by 226 · cited 4×
“one expert reader with and without plaque overlay, using transverse and MPR views [25, 28].”
BackgroundMethodInfluentialSelf-citationMachine Learning in Medicine: A Primer for Physicians
Waljee, A. K., & Higgins, P. (2010) · The American Journal of Gastroenterology · doi:10.1038/ajg.2010.173 · Cited by 158 · cited 1×
“Accordingly, machine learning techniques have emerged as highly effective methods for prediction and intelligent decision-making in many areas of everyday living [15, 16].”
MethodKo, B. S. H., Cameron, J. D., Leung, M., Meredith, I. T., Leong, D. P., Antonis, P. R., Crossett, M. P., Troupis, J. M., Harper, R. W., Malaiapan, Y. R., et al. (2012) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2012.09.004 · Cited by 148
Arsanjani, R., Xu, Y., Dey, D., Vahistha, V., Shalev, A., Nakanishi, R., Hayes, S., Fish, M., Berman, D., Germano, G., et al. (2013) · Journal of Nuclear Cardiology · doi:10.1007/s12350-013-9706-2 · Cited by 142 · cited 1×
“Recently machine learning applied to medical imaging was shown to improve diagnostic accuracy [17, 18] and prognostic outcomes [19, 20].”
BackgroundSelf-citationHausleiter, J., Meyer, T., Hadamitzky, M., Zankl, M., Gerein, P., Dorrler, K., Kastrati, A., Martinoff, S., & Schomig, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm150 · Cited by 138
Arsanjani, R., Dey, D., Khachatryan, T., Shalev, A., Hayes, S. W., Fish, M., Nakanishi, R., Germano, G., Berman, D. S., & Slomka, P. (2015) · Journal of Nuclear Cardiology · doi:10.1007/s12350-014-0027-x · Cited by 135 · cited 2×
“This method, an example of supervised ensemble learning [34] has already been shown to be efficient in predicting revascularization following ischaemia testing [30] and for prediction of all-cause mortality following coronary CTA in a multicentre international registry [19].”
MethodSelf-citationDey, D., Cheng, V., Slomka, P. J., Nakazato, R., Ramesh, A., Gurudevan, S. V., Germano, G., & Berman, D. S. (2009) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2009.09.004 · Cited by 133
Self-citationDíaz‐Zamudio, M., Dey, D., Schuhbaeck, A., Nakazato, R., Gransar, H., Slomka, P. J., Narula, J., Berman, D. S., Achenbach, S. S., Min, J. K., et al. (2015) · Radiology · doi:10.1148/radiol.2015141648 · Cited by 74 · cited 2×
“It has been shown that plaque assessment from CTA adds significantly to stenosis assessment for the identification of lesion-specific ischaemia [38, 39].”
BackgroundResultSelf-citationSchuhbaeck, A., Dey, D., Otaki, Y., Slomka, P. J., Kral, B. G., Achenbach, S. S., Berman, D. S., Fishman, E. K., Lai, S., & Lai, H. C. (2014) · European Radiology · doi:10.1007/s00330-014-3253-3 · Cited by 59 · cited 1×
“one expert reader with and without plaque overlay, using transverse and MPR views [25, 28].”
MethodSelf-citationHell, M. M., Dey, D., Marwan, M., Achenbach, S. S., Schmid, J., & Schuhbaeck, A. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.04.024 · Cited by 46
Self-citationKang, D., Slomka, P. J., Nakazato, R., Arsanjani, R., Cheng, V., Min, J. K., Li, D., Berman, D. S., Kuo, C. ‐. J., & Dey, D. (2013) · Medical Physics · doi:10.1118/1.4794480 · Cited by 23 · cited 1×
“Recently machine learning applied to medical imaging was shown to improve diagnostic accuracy [17, 18] and prognostic outcomes [19, 20].”
BackgroundSelf-citation
Cited by
Artificial Intelligence in Cardiovascular Imaging
Dey, D., Slomka, P. J., Leeson, P., Comaniciu, D., Shrestha, S., Sengupta, P. P., & Marwick, T. H. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.054 · Cited by 680
Self-citationAl’Aref, S. J., Anchouche, K., Singh, G., Slomka, P. J., Kolli, K. K., Kumar, A., Pandey, M., Maliakal, G., van Rosendael, A. R., Beecy, A. N., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy404 · Cited by 534
Self-citationvan Rosendael, A. R., Maliakal, G., Kolli, K. K., Beecy, A., Al’Aref, S. J., Dwivedi, A., Singh, G., Panday, M., Kumar, A., Ma, X., et al. (2018) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2018.04.011 · Cited by 173
“Previous studies have demonstrated that ML can increase predictive value for death and myocardial ischemia compared to conventional scores.(11,12) ML can integrate an unlimited number of input variables, does not have prior assumptions about causative factors, and does not overlook interactions between prognostically…”
BackgroundMethodSelf-citationArtificial intelligence in cardiovascular medicine: clinical applications
Lüscher, T. F., Wenzl, F. A., D’Ascenzo, F., Friedman, P. A., & Antoniades, C. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae465 · Cited by 160
Interventional Radiology Ex-Machina: Impact of Artificial Intelligence on Practice
Gurgitano, M., Angileri, S. A., Rodà, G. M., Liguori, A., Pandolfi, M., Ierardi, A. M., Wood, B. J., & Carrafiello, G. (2021) · La radiologia medica · doi:10.1007/s11547-021-01351-x · Cited by 100
Metadata
- Authors
- Dey, D., Gaur, S., Ovrehus, K. A., Slomka, P. J., Betancur, J., Goeller, M., Hell, M. M., Gransar, H., Berman, D. S., Achenbach, S., Botker, H. E., Jensen, J. M., Lassen, J. F., & Norgaard, B. L.
- Venue
- European Radiology
- Published
- 2018-01-19
- Volume
- 28
- Issue
- 6
- Pages
- 2655-2664
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2792589984
- Cited by
- 173
- References
- 44
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.