Physiological mechanisms determining eccrine sweat composition
Open accessThe DOI matches its Crossref record; 363 of the 365 references it cites were found in a registry or an index; 92 of the 523 sources its claims cite were checked for support.
Abstract
Purpose: The purpose of this paper is to review the physiological mechanisms determining eccrine sweat composition to assess the utility of sweat as a proxy for blood or as a potential biomarker of human health or nutritional/physiological status. Methods: This narrative review includes the major sweat electrolytes (sodium, chloride, and potassium), other micronutrients (e.g., calcium, magnesium, iron, copper, zinc, vitamins), metabolites (e.g., glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), and other compounds (e.g., cytokines and cortisol). Results: Ion membrane transport mechanisms for sodium and chloride are well established, but the mechanisms of secretion and/or reabsorption for most other sweat solutes are still equivocal. Correlations between sweat and blood have not been established for most constituents, with perhaps the exception of ethanol. With respect to sweat diagnostics, it is well accepted that elevated sweat sodium and chloride is a useful screening tool for cystic fibrosis. However, sweat electrolyte concentrations are not predictive of hydration status or sweating rate. Sweat metabolite concentrations are not a reliable biomarker for exercise intensity or other physiological stressors. To date, glucose, cytokine, and cortisol research is too limited to suggest that sweat is a useful surrogate for blood. Conclusion: Final sweat composition is not only influenced by extracellular solute concentrations, but also mechanisms of secretion and/or reabsorption, sweat flow rate, byproducts of sweat gland metabolism, skin surface contamination, and sebum secretions, among other factors related to methodology. Future research that accounts for these confounding factors is needed to address the existing gaps in the literature.
Overview
CoChat Summary
TL;DR
This narrative review concludes that final eccrine sweat composition is shaped not only by extracellular solute concentrations but also by glandular secretion/reabsorption, sweat flow rate, gland metabolism, skin contamination, and sebum, so sweat is not generally a reliable proxy for blood. Elevated sweat sodium and chloride remain useful for cystic fibrosis screening, but most other sweat constituents lack established blood correlations or diagnostic utility.
Key findings
- Na+ and Cl− are the most concentrated sweat electrolytes, ranging from ~10 to ~90 mmol/L; their secretion/reabsorption mechanisms are well established, but mechanisms for most other sweat solutes remain equivocal.
- Sweat-blood correlations have not been established for most constituents, with perhaps the exception of ethanol; sweat glucose is ~100× lower than blood glucose, and glucose, cytokine, and cortisol research is too limited to support sweat as a blood surrogate.
- Sweat electrolyte concentrations are not predictive of hydration status or sweating rate, and sweat metabolite concentrations are not reliable biomarkers of exercise intensity or other physiological stressors.
- Heat acclimation can decrease sweat [Na+] and [Cl−] by up to 30–60% after 7–10 days; within a bout, as forearm sweating rate increased from ~0.25 to 0.82 mg/cm2/min, sweat [Na+] rose from 19 ± 5 to 59 ± 10 mmol/L, with Na+ reabsorption falling from 86 ± 3% to 65 ± 6%.
Methods
- Narrative review of physiological mechanisms determining eccrine sweat composition during passive and active heat stress.
- Covers major electrolytes (Na+, Cl−, K+), other micronutrients (Ca2+, Mg2+, Fe2+, Cu2+, Zn2+, vitamins), metabolites (glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), cytokines, and cortisol.
- Synthesizes literature on secretion/reabsorption, collection and analytical confounders, heat acclimation/diet/training effects, and sweat-versus-blood correlations, including Table 1 ranges and supplemental tables.
Limitations
- Stated: mechanisms of secretion/reabsorption for most non-Na/Cl solutes are still equivocal; few well-designed, adequately powered sweat-blood correlation studies exist; methodological confounds include skin surface contamination, collection method, storage, and analytical technique; normative data are insufficient for most constituents; no longitudinal training studies and no sweat-blood cortisol comparisons are available.
- Evident from the text: as a narrative review, it does not use a systematic search or meta-analysis, and many cited studies are old, small, or report mixed/equivocal results, with the authors repeatedly calling for more controlled research.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
76 Valid · 13 Not valid · 213 Not checked · 79 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“some in vitro experiments suggest that ion channel (ENaC) activity is temperature dependent, such that higher temperature increases excitability and open probability”
§ Physiological mechanisms determining eccrine sweat composition > Mechanisms determining sweat composition > Electrolytes (sodium, chloride, and potassium)
What the sources say
- Disputedcites Chraibi and Horisberger 2002 matched to “Na Self Inhibition of Human Epithelial Na Channel” (2002) sourceExperimental — accuracy not yet measured
The Results section (‘Effect of Temperature on the Steady-State Amiloride-sensitive Current’) reports that, under control conditions, ENaC current decreased as temperature rose; it increased only after protease treatment. The Discussion (‘Effect of Temperature and Kinetics of Self Inhibition’) says high temperature favors the low-open-probability state, contrary to the claimed increase in open probability. (LLM, conf=0.90)
Checked by a reasoning model — may be wrong.
- Disputedcites Chraibi and Horisberger 2003 matched to “Dual effect of temperature on the human epithelial Na + channel” (2003) sourceExperimental — accuracy not yet measured
The Discussion (p. 5) reports that ENaC open probability increased 2.3-fold on cooling, contrary to the claim that higher temperature increases it. The paper does report greater unitary current at higher temperature, but that is distinct from open probability; it does not establish increased excitability. (LLM, conf=0.89)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites Ruff 1999 matched to “Effects of temperature on slow and fast inactivation of rat skeletal muscle Na+channels” (1999) source
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“There is no experimental evidence that alcohol ingestion leads to an increase in sweating rate (Baker 2019).”
§ Physiological mechanisms determining eccrine sweat composition > Mechanisms determining sweat composition > Metabolites
What the sources say
- Disputedcites Baker 2019 matched to “Physiology of sweat gland function: The roles of sweating and sweat composition in human health” (2019) sourceExperimental — accuracy not yet measured
In “Excretion of ethanol,” Baker reports that one laboratory study found a higher chest sweating rate 10–30 minutes after alcohol ingestion than after water. The increase was small and transient, and other studies found no difference, but the reported experiment contradicts the claim that there is no experimental evidence of an increase. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Since extracellular fluid is the precursor to primary sweat in the secretory coil of eccrine sweat glands (Cage and Dobson 1965; Sato 1977)”
§ Physiological mechanisms determining eccrine sweat composition > Introduction
What the sources say
- Supportedcites Cage and Dobson 1965 matched to “Sodium Secretion and Reabsorption in the Human Eccrine Sweat Gland*” (1965) source
The Discussion states that the precursor of the secretory fluid must be interstitial fluid or blood plasma, both extracellular fluids. The paper also describes the secretory fluid as being produced in the secretory coil. (LLM, conf=0.93)
- Not checked — no full text of the sourcecites Sato 1977 matched to “The physiology, pharmacology, and biochemistry of the eccrine sweat gland” (1977) source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“its application has been limited to date (Brothers et al. 2019; Gao et al. 2018; Heikenfeld et al. 2018).”
§ Physiological mechanisms determining eccrine sweat composition > Introduction
What the sources say
- Not checked — no full text of the sourcecites Brothers et al. 2019 matched to “Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms” (2019) source
- Supportedcites Gao et al. 2018 matched to “Wearable physiological systems and technologies for metabolic monitoring” (2018) source
The ‘Effects of environment on measuring sweat’ section says wearable sweat-monitoring devices existed as research prototypes but were not yet commercially available. It also describes practical barriers to their use, supporting the claim that application had been limited to date. No page number is provided in our copy. (LLM, conf=0.90)
- Supportedcites Heikenfeld et al. 2018 matched to “Wearable sensors: modalities, challenges, and prospects” (2018) source
The Wearable Chemical Sensors section reports demonstrations of non-invasive, real-time sweat monitoring but says that no commercial wearable products for sweat-based chemical detection yet exist. Its discussion of unresolved sampling and validation challenges supports the claim that practical application remained limited; the passage has no page number in our copy. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Whole body sweating rate can be > 3.0 L/h (Armstrong et al. 1986; Barnes et al. 2019; Bergeron 2003; Godek et al. 2005, 2010; Palmer and Spriet 2008).”
§ Physiological mechanisms determining eccrine sweat composition > Eccrine sweat glands and thermoregulatory sweating
What the sources say
- Not checked — no full text of the sourcecites Armstrong et al. 1986 matched to “Preparing Alberto Salazar for the Heat of the 1984 Olympic Marathon” (1986) source
- Partly supportedcites Barnes et al. 2019 matched to “Normative data for sweating rate, sweat sodium concentration, and sweat sodium loss in athletes: An update and analysis by sport” (2019) sourceExperimental — accuracy not yet measured
Our copy of Barnes et al. (2019) repeatedly documents whole-body sweating rate (WBSR) in athletes and 'considerable overall inter-individual variation in sweating' (Conclusion; Discussion, p. n/a), with the highest sport means in American football (1.51 ± 0.70 L/h) and endurance (1.28 ± 0.57 L/h) (ABSTRACT; Table 3). However, no passage states that WBSR can exceed 3.0 L/h; the only explicit high-rate threshold given is that 'three of the 24 endurance athletes tested outdoors had sweating rates over 2.0 L/h' (Results, descriptive statistics), and the '>3–4' figure in the Introduction refers to grams of Na+ loss, not sweating rate. The range/maximum values that could carry the >3.0 L/h magnitude sit in Tables 2–3, which are not rendered in our copy (placeholder rows only). So the source supports high and highly variable WBSR in athletes but not the specific >3.0 L/h magnitude attributed to it. (LLM, conf=0.68)
- Not checked — no full text of the sourcecites Bergeron 2003 matched to “Heat cramps: fluid and electrolyte challenges during tennis in the heat” (2003) source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
257 more claims · 59 with their cited sources checked
Create a free account to see all 381 claims and to verify the 11 references still open.
- Probably not a substantial claim. 40
- It may state two separate claims as one. 90
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Physiological mechanisms determining eccrine sweat composition > Overview of sweat composition
“| Amino Acids | R–CH(NH2) –COOH | ≤ 13 × 10–3 each | ≤ 6.5 × 10–3 each | 75–204 each | Polar and nonpolar | Leaching of natural moisturizing factors from the skin | NA |”
§ Physiological mechanisms determining eccrine sweat composition > Effects of heat acclimation, diet, and physical training on sweat composition > Metabolites
“total amino acid concentrations in sweat were significantly lower in trained (physically active for an average of 9 h per week) than untrained (average of 1 h of sports per week) men during 15 min of cycling at 150 W while covered with a plastic blanket (12,797 vs. 24,855 µmol/L, respectively).”
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
American College of Sports Medicine position stand
Otis, C. L. (1997) · Medical Entomology and Zoology · Cited by 4,407
Webb, A. K. (2006) · Cited by 4,369
Cytokines, Inflammation, and Pain
Zhang, J.-M., & An, J. (2007) · International Anesthesiology Clinics · doi:10.1097/aia.0b013e318034194e · Cited by 2,945
USSING, H. H., & ZERAHN, K. (1951) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1951.tb00800.x · Cited by 2,406
Adaptations of skeletal muscle to endurance exercise and their metabolic consequences
Holloszy, J. O., & Coyle, E. F. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.4.831 · Cited by 1,985
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Salivary Cortisol in Psychobiological Research: An Overview
Kirschbaum, C., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000118611 · Cited by 1,532
Exercise and Fluid Replacement
(2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802ca597 · Cited by 1,497
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · cited 2×
“, pilocarpine or methacholine) transdermally to stimulate the muscarinic receptors on the sweat glands (Gibson and Cooke 1959; Webster 1983).”
Background
Research works printed but not linked: 9
- Brunner H Über Glykogen in der gesunden und kranken Haut Verh Dtsch derm Gesellschaft 1906 9 521 535
- Embden R Tachau H Uber das Vorkommen von Serin im menschlichen Schweisse Biochem Ztschr 1910 28 230
- Kirschbaum C Hellhammer DH Fink G Salivary cortisol Encyclopedia of stress 2000 2 New York Academic 405 409
- Kuno Y Human perspiration 1956 Springfield Charles C. Thomas Publisher
- Kutchai HC Berne RM Levy MN Cellular membranes and transmembrane transport of solute and water Physiology 1998 St. Louis Mosby Press 3 20
- Ladell WSS Shephard RJ Aldosterone inhibition and acclimatization to heat Proc Physiol Soc 1961 3–4 19P 20P
- Sato K Gisolfi CV Nadel ER The mechanism of eccrine sweat secretion Exercise, heat, and thermoregulation Perspectives in exercise science and sports medicine 1993 Dubuque Brown & Benchmark 85 117
- Wescor Sweat Chek™ sweat conductivity analyzer model 3120 instruction/service manual 2005 USA Wescor Inc
- Yuyama H On the histological examination of distribution of glycogen in the skin of leprosy with special reference to the relationship between the function of sweat glands and the changes of glycogen content J Derm Urol 1935 37 811 832
Cited by
Items 101–200 of 348
Molecular and Functional Basis of High-Salt Avoidance in a Blood-Sucking Insect
Pontes, G. B., Latorre-Estivalis, J. M., Gutiérrez, M. L., Cano, A., de Astrada, M. B., Lorenzo, M. G., & Barrozo, R. B. (2022) · iScience · doi:10.1016/j.isci.2022.104502 · Cited by 29
“Besides, salts are found on human skin as part of sweat, a product of the eccrine glands’ excretion (Baker and Wolfe, 2020; Buono et al., 2007; Cage and Dobson, 1965).”
BackgroundInfluentialA comprehensive review on electrochemical cytokine detection in sweat
Ploner, M., Petrelli, M., Shkodra, B., Tagliaferri, A., Lugli, P., Resnati, D., Petti, L., & Angeli, M. A. C. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.101985 · Cited by 34
Non-invasive monitoring of low molecular weight biomarkers relevant to skin inflammation and cancer
Jankovskaja, S. (2021) · doi:10.24834/isbn.9789178772230 · Cited by 25
Wearable continuous diffusion-based skin gas analysis
Clausen, D. M., Farley, M., Little, A., Kasper, K. A., Moreno, J., Limesand, L., & Gutruf, P. (2025) · Nature Communications · doi:10.1038/s41467-025-59629-x · Cited by 27
“During steady-state exercise, trends of increasing H2O and CO 2 occur due toaerobic metabolism 26,69 .”
Steijlen, A. S. M., Bastemeijer, J., Groen, P., Jansen, K. M. B., French, P. J., & Bossche, A. (2020) · Analytical Methods · doi:10.1039/d0ay02014a · Cited by 21
Transdermal sensing: in-situ non-invasive techniques for monitoring of human biochemical status
Iitani, K., Ramamurthy, S. S., Ge, X., & Rao, G. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.08.005 · Cited by 19
Virtual reality for biochemistry education: the cellular factory
Barrow, J., Hurst, W., Edman, J., Ariesen-Verschuur, N., & Krampe, C. (2023) · Education and Information Technologies · doi:10.1007/s10639-023-11826-1 · Cited by 33
“Participant specific factors concern baseline sweat gland activity, sebum secretion and levels of electrolytes present on the skin surface (Bake & Wolfe, 2020).”
BackgroundPloner, M., Shkodra, B., Franchin, L., Altana, A., Petrelli, M., Angeli, M. A. C., Ciccone, G., Antrack, T., Vanzetti, L., Nair, R. R., et al. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117734 · Cited by 27
Burat, B., Reynaerts, A., Baiwir, D., Fléron, M., Eppe, G., Leal, T., & Mazzucchelli, G. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910871 · Cited by 24
“In the context of heat acclimation and aerobic-exercise-related conditions, anthropometric parameters such as age, sex and body mass index were identified as notable sources of the intra- and inter-individual variability of sweat secretion [16,17], e.”
BackgroundThe interstitial compartment as a therapeutic target in heart failure
Aronson, D. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.933384 · Cited by 21
“These sweat glands are responsible for the greatest volume of sweat excretion (141, 142).”
BackgroundMa, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 21
“…from continuous monitoring of sweat gland activity by using an algorithm known as the sweat lactate curve [79], even though some researchers have concluded that this only provides information about sweat gland metabolism and does not provide insight into the clinical use of sweat lactate [74,80].”
Zhong, B., Xu, H., Qin, X., Liu, L., Wang, H., & Wang, L. (2024) · Bio-Design and Manufacturing · doi:10.1007/s42242-024-00294-2 · Cited by 22
Gao, R., Khatib, M., & Bao, Z. (2026) · npj Biosensing · doi:10.1038/s44328-025-00065-8 · Cited by 24
“Apocrine glands are locatedatspeci fi canatomicalregions,suchastheaxillaandsecreteaviscous, lipid-rich fl uid into hair follicles 24,25 .”
Enhancing Sweat Rate Using a Novel Device for the Treatment of Congestion in Heart Failure
Aronson, D., Nitzan, Y., Petcherski, S., Bravo, E., Habib, M., Burkhoff, D., & Abraham, W. T. (2022) · Circulation Heart Failure · doi:10.1161/circheartfailure.122.009787 · Cited by 21
Yang, M., Sun, N., Lai, X., Zhao, X., & Zhou, W. (2023) · Biosensors · doi:10.3390/bios14010017 · Cited by 19
“Sampling is an essential component for sweat detection, responsible for gathering and transporting sweat samples to the detection area, where the sensing element is located.”
BackgroundQuantification of Cannabis in Infused Consumer Products and Their Residues on Skin
Quiñones, R., Moreno, S., Smythers, A. L., Sullins, C., Pijor, H., Brown, G. J., Trouten, A., Richards‐Waugh, L. L., & Siddig, A. (2022) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.2c00077 · Cited by 18
Mai, K., Maverakis, E. M., Li, J., et al. (2023) · Advances in Wound Care · doi:10.1089/wound.2022.0128 · Cited by 17
“17 An osmotic drive in the outer epidermis aids in maintaining epidermal hydration by preventing excessive passive water loss through evap-oration.”
Lu, L., Sun, Q., Lin, Z., Xu, W., Li, X., Wang, T., Lu, Y., Wu, H., Cheng, L., & Liu, A. (2025) · Biosensors · doi:10.3390/bios15060342 · Cited by 22
Capillary-osmotic wearable patch based on lateral flow assay for sweat potassium analysis
Mukherjee, S., Salazar, S. P., Saha, T., Dickey, M. D., & Velev, O. D. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136383 · Cited by 17
Skin Structure and Functions of the Skin
Prohić, A. (2024) · Springer eBooks · doi:10.1007/978-3-031-66131-0_1 · Cited by 21
Kinetic changes in sweat lactate following fatigue during constant workload exercise
Okawara, H., Sawada, T., Nakashima, D., Maeda, Y., Minoji, S., Morisue, T., Katsumata, Y., Matsumoto, M., Nakamura, M., & Nagura, T. (2022) · Physiological Reports · doi:10.14814/phy2.15169 · Cited by 16
A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate
Wang, H., Xu, K., Xu, H., Huang, A., Fang, Z., Zhang, Y., Wang, Z., Lu, K., Wan, F., Bai, Z., et al. (2022) · Micromachines · doi:10.3390/mi13030414 · Cited by 17
“Furthermore, sweat, like saliva and tears [6], is noninvasively induced from deeper in the body and carries a diverse array of biomolecules, ranging from small electrolytes (including Na+, K+, and Ca2+) and metabolites (such as glucose, lactate [7], and ethanol [8]) to hormones and larger proteins [9], which may provi…”
BackgroundMulti-biosensing hairband for emergency health assessment
Li, M., Li, G., Xu, T., Wang, Y., Xu, R., Zhang, X., Chen, F., Yu, N., & Tian, M. (2025) · Nature Communications · doi:10.1038/s41467-025-62556-6 · Cited by 24
Wearable Sweat Management Technologies
Wei, L., Li, Z., Dai, Z., Ding, L., Wei, H., Li, J., Zhu, H., & Zhu, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301812 · Cited by 21
Tian, L., Cai, L., Ding, Z., Zhou, Y., Zhang, Y., Liu, Q., Ge, X., & Yu, C. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110417 · Cited by 17
Quantification of amino acids in small volumes of palm sweat samples
Tsunoda, M., & Tsuda, T. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e36286 · Cited by 14
“Comprising about 99 % water, sweat also contains essential ions like chloride, sodium, and potassium, along with smaller amounts of calcium, magnesium, lactate, and other minor electrolytes [6,7].”
BackgroundEstimation of maximal lactate steady state using the sweat lactate sensor
Muramoto, Y., Nakashima, D., Amano, T., Harita, T., Sugai, K., Daigo, K., Iwasawa, Y., Ichihara, G., Okawara, H., Sawada, T., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-36983-8 · Cited by 17
Dual-Valved Skin-Interfaced Microfluidic Device for Programmed Time-Control Sweat Collection
Yang, J. H., David, U., Noh, Y. S., & Koh, A. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134441 · Cited by 22
Omran, F. S., Kaminsky, V. V., Emelyanenko, K. A., Emelyanenko, A. M., & Boinovich, L. B. (2023) · Colloid Journal · doi:10.1134/s1061933x23600641 · Cited by 15
“To explain the observed change in wettability, it is important to note that the composition of sweat secretions is highly dependent on environmental conditions, physical activity, temperature, and many other parameters, and varies greatly for each individual [28– 30].”
Katsumata, Y., Muramoto, Y., Ishida, N., Takemura, R., Nagashima, K., Ikoma, T., Kawamatsu, N., Araki, M., Goda, A., Okawara, H., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-70001-9 · Cited by 16
“To date, sweat lactate sensors are considered impractical alternatives to measuring blood lactate levels because the dynamics of sweat lactate is different from that of blood lactate [6-8].”
BackgroundWeiss, K., Valero, D., Villiger, E., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0312097 · Cited by 14
Sebaceous origins of human odor
Zung, J. L., & McBride, C. S. (2025) · Current Biology · doi:10.1016/j.cub.2025.03.031 · Cited by 18
Brasier, N., Niederberger, C., Zanella, M., Othman, A., Schlapbach, R., Kunz, L., Dittmann, A., Reeve, K. A., Prummer, M., & Goldhahn, J. (2025) · Communications Biology · doi:10.1038/s42003-025-08080-1 · Cited by 18
Laochai, T., Nishihara, H., Qin, J., Okhawilai, M., Wang, J., Rodthongkum, N., & Sukmas, W. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.138882 · Cited by 16
The effect of sweat sample storage condition on sweat content
Klous, L., Folkerts, M. A., Daanen, H. A. M., & Gerrett, N. (2021) · Temperature · doi:10.1080/23328940.2020.1867294 · Cited by 16
“Other sources of variation may be associated with the different methods of sweat collection and analysis [1].”
BackgroundMethodInfluentialKing, M. A., Brown, S. D., Barnes, K. A., Chavez, P. J. D. D., & Baker, L. B. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05187-3 · Cited by 16
“These locations were chosen, because they are among those most commonly reported in the literature (Baker and Wolfe 2020) and the RDF and RT in particular are likely regions for wearable devices.”
BackgroundInfluentialSelf-citationVittrant, B., Ayoub, H., & Brunswick, P. (2024) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2024.1454095 · Cited by 16
Aggregation behavior of photoaging nanoplastics in artificial sweat solutions
Yang, Y., Song, H., Cao, Y. L., Li, J., Li, J., Cui, X., Hu, X., Mahfuza, A., Ning, P., Zhang, L., et al. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.137466 · Cited by 14
Coşkun, A., Savaş, İ. N., Can, O., & Lippi, G. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2453152 · Cited by 16
Luo, R., Yang, Y., Huang, S., & Huang, Z. (2025) · Sensors and Actuators Reports · doi:10.1016/j.snr.2025.100339 · Cited by 23
Recent Advances in Wearable Sweat Sensor Development
Zhang, T., Kabandana, G. K. M., Terrell, J. A., Chen, H., & Chen, C. (2025) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.70006 · Cited by 15
Fatani, F., Rauf, S., Banerjee, A., & Shamim, A. (2025) · ACS Sensors · doi:10.1021/acssensors.5c00470 · Cited by 16
“13 − 20 This correlation is important, as it suggests that sweat lactate may serve as a reliable, noninvasive alternative for detecting LT. Analyzing lactate concentration in sweat has been established using reliable methods such as high-performance liquid chromatography (HPLC).”
Exertional heat stress and sodium balance: Leaders, followers, and adaptations
McCubbin, A. J. (2021) · Autonomic Neuroscience · doi:10.1016/j.autneu.2021.102863 · Cited by 13
Sánchez, A., Shalan, A. E., Rosales, M., et al. (2022) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2022.117052 · Cited by 12
Light-induced antifungal activity of nanoparticles with an encapsulated porphyrin photosensitizer
Kodedová, M., Liška, V., Mosinger, J., & Sychrová, H. (2023) · Microbiological Research · doi:10.1016/j.micres.2023.127303 · Cited by 13
García-Rey, S., Gil-Hernández, E., Gunatilake, U. B., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133514 · Cited by 12
The influence of local skin temperature on the sweat glands maximum ion reabsorption rate
Gerrett, N., Amano, T., Havenith, G., Inoue, Y., & Kondo, N. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-018-04059-5 · Cited by 11
Alcohol as a Non-UV Social-Environmental Risk Factor for Melanoma
Yamauchi, T., Shangraw, S., Zhai, Z., Menon, D. R., Batta, N., Dellavalle, R. P., & Fujita, M. (2022) · Cancers · doi:10.3390/cancers14205010 · Cited by 16
“[129,130], with an almost equal concentration to blood concentration [131].”
BackgroundWang, C., Guo, Y., Han, G., Zhou, Y., & Nyein, H. Y. Y. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116769 · Cited by 12
Liu, X., Huang, S., Ma, L., Ye, H., Lin, J., Cai, X., Shang, Q., Zheng, C., Xu, R., & Zhang, D. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.115006 · Cited by 13
To touch or not to touch? Fingerprint-assisted grinding of carbamazepine form III
Zheltikova, D., Losev, E. A., & Boldyreva, E. V. (2023) · CrystEngComm · doi:10.1039/d3ce00544e · Cited by 11
Presta, V., Ambrosini, L., Carubbi, C., Masselli, E., Mirandola, P., Arcari, M. L., Gobbi, G., & Vitale, M. (2021) · Water · doi:10.3390/w13020166 · Cited by 18
Seeing inside the Body Using Wearable Sensing and Imaging Technologies
Kim, S., Han, S., Park, S., & Koo, J. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202502480 · Cited by 13
Karaman, C., Aydemir, M., & Karaman, O. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118687 · Cited by 15
Molecular biomarkers for assessing the heat-adapted phenotype: a narrative scoping review
Corbett, J., Young, J. S., Tipton, M., Costello, J. T., Williams, T. B., Walker, E. F., Lee, B., & Stevens, C. E. (2023) · The Journal of Physiological Sciences · doi:10.1186/s12576-023-00882-4 · Cited by 10
“…is primarily composed of water, it also contains a mixture of chemicals in varying concentrations, including electrolytes (Na + , Cl − , K + , Ca 2 ), micronutrients (vitamins), metabolites (e.g. glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), cytokines, and cortisol [13].”
BackgroundNelson, R. S., Grossman, M. G., Klug, Z. M., Calamari, M., Donayre, A., Cybulski, T. R., Schooley, J., Griffith, G. J., Corcos, D. M., Wright, D. E., et al. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2506137122 · Cited by 14
“Other potential contributors to day - to - day variability include hydration status, salt intake, or exercise intensity ( 24 ).”
Real-time smart multisensing wearable platform for monitoring sweat biomarkers during exercise
Lafaye, C., Rovira, M., Demuru, S., Wang, S., Kim, J., Kunnel, B. P., Besson, C., Fernández‐Sánchez, C., Serra-Graells, F., Margarit, J. M., et al. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948565 · Cited by 14
“Sweat analysis during exercise is promising for various reasons: (1) the link between body sweat loss and dehydration/salt loss [4]; (2) the need of athletes or workers in hot conditions to have a tool to improve real time hydration management [5], [6]; (3)”
BackgroundIntegrated Device Based on a Sudomotor Nanomaterial for Sweat Detection
Gong, L., Bonmarin, M., Spano, F., Shen, Y., Shen, L., Han, G., Wei, S., Zhang, Q., Chen, Z., & Zhao, F. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c03401 · Cited by 11
A fully wearable conductive yarn-based sweat sensor powered by shoe insole-based TENG
Johns, M., Puluckul, P. P., Singh, R. K., Parrilla, M., Wael, K. D., & Weyn, M. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.138166 · Cited by 11
Smart wearable photonic array biosensor for human sweat analysis
Hussain, S., Ramadan, Q., & Zourob, M. M. (2025) · Soft Science · doi:10.20517/ss.2025.02 · Cited by 13
Lu, T., Fan, J., You, S., Adiraju, A., Guo, Y., Talbi, M., Jaradat, H., & Kanoun, O. (2025) · Emergent Materials · doi:10.1007/s42247-025-01279-2 · Cited by 10
Salt and water balance after sweat loss: A study of Bikram yoga
Alrefai, H., Mathis, S. L., Hicks, S. M., Pivovarova, A. I., & MacGregor, G. G. (2020) · Physiological Reports · doi:10.14814/phy2.14647 · Cited by 7
“However, potassium, lactate, and urea are frequently measured in sweat at higher concentrations than in plasma (Baker & Wolfe, 2020).”
BackgroundWei, L., Lv, Z., He, Y., Guo, D., Cheng, L., Wu, H., & Liu, A. (2022) · Biosensors · doi:10.3390/bios13010067 · Cited by 10
“Notice that chloride ions and bicarbonates are most abundant ions in sweat, while the concentration of chloride ions is approximately 20 times greater than that of bicarbonates in sweat [32].”
BackgroundInfluentialWearable Electronic Tongue for Non-Invasive Assessment of Human Sweat
Falk, M., Nilsson, E. J., Cirovic, S., Tudosoiu, B., & Shleev, S. (2021) · Sensors · doi:10.3390/s21217311 · Cited by 10
“Compound Concentration (mM) Lactate 5–40 (Ref [45]) Glucose 0.”
BackgroundSweat as a diagnostic biofluid: analytical advances and future directions
Bordin, D. M., McCauley, J. I., de Campos, E. G., Bishop, D., & Martinis, B. S. D. (2025) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2025.101473 · Cited by 11
“1) [20,21].”
InfluentialYang, F., Han, X. D., Ai, Y., Shao, B., Ding, W., Tang, K., & Sun, W. (2024) · Molecules · doi:10.3390/molecules29030744 · Cited by 8
“Thus, the detection of DA in sweat sample can lead to a non-invasive analysis with real-time monitoring [4,5], which is convenient for disease diagnostics and health control.”
BackgroundWang, X., Han, L., Hu, X., et al. (2021) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2021.113614 · Cited by 8
Eckl, D. B., Hoffmann, A. K., Landgraf, N., Kalb, L., Bäßler, P., Wallner, S., Eichner, A., Huber, H., Hackbarth, S., & Bäumler, W. (2023) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.19113 · Cited by 9
“43 Among these substances, amino acids like histidine are important because they show high rate constants for singlet oxygen quenching, while the values for fatty acids are negligibly smaller.”
BackgroundSiddiqui, S. H., Park, J., Kang, D., Khan, M., & Shim, K. S. (2021) · Tissue and Cell · doi:10.1016/j.tice.2021.101615 · Cited by 9
Wang, Q., & Li, T. (2025) · Analytical Methods · doi:10.1039/d5ay00941c · Cited by 10
Ntuli, L. M., Nyembwe, A., Mwengula, G., Munonde, T. S., & Mulopo, J. L. (2025) · International Journal of Electrochemical Science · doi:10.1016/j.ijoes.2025.101184 · Cited by 11
Bandiera, D., de Bardonnèche, J., Margout, D., Dubois, L., Allaoui, N. E., Rubio, J., Aubin, J.-C., Racinais, S., Tessitore, A., & Pitsiladis, Y. P. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2025.1717275 · Cited by 10
Multimodal biosensing platforms for sensor-computing integration towards intelligent healthcare
Guo, W., Zahran, A., El-Shal, I. H., Guo, Y., Eldamak, A. R., Fahmy, O. M., Yuan, Z., Tai, H., Elsheakh, D. N., & Lin, Y. (2026) · Soft Science · doi:10.20517/ss.2025.108 · Cited by 14
Development of an insilico model of eccrine sweat using molecular modelling techniques
Deshpande, P., Ravikumar, B., Tallur, S. G., Paul, D., & Rai, B. (2022) · Scientific Reports · doi:10.1038/s41598-022-24440-x · Cited by 6
Blechert, O., Xiong, S., Chen, J., Brand, A., & Zhan, P. (2023) · Fungal Biology Reviews · doi:10.1016/j.fbr.2023.100330 · Cited by 10
Obma, A., Nookaew, K., Songsaeng, R., Phonchai, A., Hauser, P. C., Wilairat, P., & Chantiwas, R. (2023) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2023.105255 · Cited by 9
McCubbin, A. J., & Costa, R. J. S. (2023) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2023-0295 · Cited by 7
Daci, D., Altrichter, S., Grillet, F. M., Dib, S., Mouna, A., Kumar, S. S., Terhorst‐Molawi, D., Maurer, M., Günzel, D., & Scheffel, J. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25094658 · Cited by 7
“Na + Na + is removed from the cytoplasm via the Na + /K + ATPase, and K + is extruded via basolateral K + channels [28]. is removed from the cytoplasm via the Na + /K + ATPase, and K + is extruded via basolateral K + channels [28].”
BackgroundInfluentialThe Impact of Nutritional Supplementation on Sweat Metabolomic Content: A Proof-of-Concept Study
Harshman, S. W., Browder, A. B., Davidson, C. N., Pitsch, R. L., Strayer, K. E., Schaeublin, N. M., Phelps, M. S., O’Connor, M. L., Mackowski, N. S., Barrett, K. N., et al. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.659583 · Cited by 7
Lactate threshold evaluation in swimming using a sweat lactate sensor: A prospective study
Okawara, H., Sawada, T., Nakashima, D., Fujitsuka, H., Muramoto, Y., Hinokuma, D., Oshikiri, Y., Ishizaki, K., Miki, J., Hara, R., et al. (2024) · European Journal of Sport Science · doi:10.1002/ejsc.12179 · Cited by 9
“Originally, sLA levels were reported to not reflect bLA levels during land ‐ based exercise (Baker & Wolfe, 2020).”
BackgroundDeshpande, P., De, D., Badhe, Y. P., Tallur, S. G., Paul, D., & Rai, B. (2024) · Scientific Reports · doi:10.1038/s41598-024-73044-0 · Cited by 6
A sweat sensor for simultaneous detection of multiple thyroid health biomarkers
Liu, C., Zhao, H., Karbarz, M., Wang, H., & Zhang, Q. M. (2025) · Talanta · doi:10.1016/j.talanta.2025.128585 · Cited by 9
Advances and Challenges in Wearable Sensors for Health Monitoring
Brazaca, L. C., Lozano, A. M., Mayol, B., Scheidt, D. T., Fazio, D. D., Kim, E., Maroli, G., Rosati, G., Ates, H. C., Wang, H., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c04520 · Cited by 13
Prenatal and early life factors and type 1 diabetes
Abela, A. G., & Fava, S. (2022) · Endocrine · doi:10.1007/s12020-022-03057-0 · Cited by 9
“Sweat is source of ammonia [25], which can be oxidised by ammonia-oxidising bacteria (AOB) and ammonia-oxidising archaea (AOA) to nitrite and nitric oxide (NO) [26].”
BackgroundGotsmy, M., Brunmair, J., Bueschl, C., Gerner, C., & Zanghellini, J. (2022) · BMC Bioinformatics · doi:10.1186/s12859-022-04918-1 · Cited by 5
“sweat but from the surface of the skin in sweat measurements) [44] or by experimental handling [45].”
BackgroundBrown, H. A., Clark, B., & Périard, J. D. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05447-w · Cited by 9
“Sodium in particular, is purported to be key for maintaining plasma osmolality and regulating fluid movement between the intra-and extra-cellular compartments (Baker and Wolfe 2020).”
BackgroundAcevedo, C. M. D., Gómez, J. K. C., Gomez, G. A. B., Carrero-Carrero, J. L., & Flores‐Ramírez, R. (2025) · Cancers · doi:10.3390/cancers17172742 · Cited by 9
“…is predominantly composed of water and contains electrolytes (e.g., sodium, potassium, chloride, magnesium, calcium), along with amino acids, fatty acids, nitrogenous metabolites, and lipids, all of which provide valuable insights into an individual’s metabolic and physiological state [36,37].”
The valley of death in translation: Challenges and pathways for wearable microfluidic sweat sensors
Yan, H., Fu, S., & Guo, Z. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.170306 · Cited by 6
Ozbey, S., AKKAŞ, T., Kaplan, T. E., Polatoğlu, İ., Şen, M., & Kurbanoğlu, S. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118698 · Cited by 8
Wojcieszek, J., Wojciechowska, I., Dominiczak, J., Krzemiński, J., Pepłowski, A., & Górski, Ł. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136475 · Cited by 5
Self-assembled thin films as alternative surface textures in assistive aids with users who are blind
Swain, Z. R., Derkaloustian, M., Hepler, K. A., Nolin, A., Damani, V. S., Bhattacharyya, P., Shrestha, T., Medina, J., Kayser, L. V., & Dhong, C. (2024) · Journal of Materials Chemistry B · doi:10.1039/d4tb01646g · Cited by 9
Balch, A., Cardei, M. A., Kranz, S., & Doryab, A. (2025) · ACM Transactions on Computing for Healthcare · doi:10.1145/3743690 · Cited by 13
Ode to Salt: Commentary on “Skin Sodium Accumulates in Psoriasis and Reflects Disease Severity”
Mauro, T. M. (2021) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2021.08.401 · Cited by 6
Incidence of exercise-associated hyponatremia during a high-altitude 161-km ultramarathon
Khodaee, M., Saeedi, A., Harris-Spinks, C., & Hew‐Butler, T. (2021) · Physical Activity and Nutrition · doi:10.20463/pan.2021.0016 · Cited by 7
Cost-effective and portable electrochemical sensing of sweat constituents via printed electrodes
Dai, J., Jin, L., & Zhou, D. (2025) · International Journal of Electrochemical Science · doi:10.1016/j.ijoes.2025.101164 · Cited by 7
Odor-based individual authentication
Tanaka, W., Jirayupat, C., Honda, H., Liu, J., Hosomi, T., Takahashi, T., & Yanagida, T. (2025) · Chemical Communications · doi:10.1039/d5cc02465j · Cited by 5
Wireless passive fabric sensor for multi-ion detection in human sweat
Xia, Z., Guo, F., Chen, X., Zhang, F., Zhang, Z., Li, J., Huang, L., Xu, Z., Ming, X., & Peng, Y. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118090 · Cited by 7
Elizondo-Elizondo, M., González-Silva, A., de Oca, G. M., Tirado‐Sánchez, A., León, M. G. F.-D., Diaz-Molina, V. L., Acosta‐Altamirano, G., & Bonifáz, A. (2025) · Future Microbiology · doi:10.1080/17460913.2025.2607353 · Cited by 5
Zhao, H., Zhang, X., Khan, W. U., Karbarz, M., & Zhang, Q. M. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202502468 · Cited by 10
“In adults, the average daily sweat secretion is approximately 500– 700 mL [ 38, 39 ].”
Influential
Metadata
- Authors
- Baker, L. B., & Wolfe, A. S.
- Affiliations
- Gatorade Sports Science Institute (US)
- Corresponding author
- Baker, Lindsay B.
- ORCID
- Baker, Lindsay B.
- Venue
- European Journal of Applied Physiology
- Published
- 2020-03-02
- Volume
- 120
- Issue
- 4
- Pages
- 719-752
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- PMC
- PMC7125257
- OpenAlex
- W3010240226
- Semantic Scholar
- 3a7f3eeeee43ce9bbcb7b652fe248abe7d8d2ac5
- Cited by
- 367
- References
- 365
- Citations by year
- 2026: 85 · 2025: 76 · 2024: 66 · 2023: 53 · 2022: 40 · 2021: 34 · 2020: 10
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- European Journal of Applied Physiology (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Gatorade Sports Science Institute (NA)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- eccrine sweat, sweat composition, sweat electrolytes, sodium, chloride, potassium, sweat biomarkers, cystic fibrosis screening, cortisol, exercise intensity
- MeSH terms
- Acclimatization, Eccrine Glands, Electrolytes, Humans, Specimen Handling, Sweat, Sweating, Sodium Chloride, Dietary, Micronutrients, Physical Conditioning, Human
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.