Physiological mechanisms determining eccrine sweat composition
Open accessThe DOI matches its Crossref record; 363 of the 365 references it cites were found in a registry or an index; 92 of the 523 sources its claims cite were checked for support.
Abstract
Purpose: The purpose of this paper is to review the physiological mechanisms determining eccrine sweat composition to assess the utility of sweat as a proxy for blood or as a potential biomarker of human health or nutritional/physiological status. Methods: This narrative review includes the major sweat electrolytes (sodium, chloride, and potassium), other micronutrients (e.g., calcium, magnesium, iron, copper, zinc, vitamins), metabolites (e.g., glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), and other compounds (e.g., cytokines and cortisol). Results: Ion membrane transport mechanisms for sodium and chloride are well established, but the mechanisms of secretion and/or reabsorption for most other sweat solutes are still equivocal. Correlations between sweat and blood have not been established for most constituents, with perhaps the exception of ethanol. With respect to sweat diagnostics, it is well accepted that elevated sweat sodium and chloride is a useful screening tool for cystic fibrosis. However, sweat electrolyte concentrations are not predictive of hydration status or sweating rate. Sweat metabolite concentrations are not a reliable biomarker for exercise intensity or other physiological stressors. To date, glucose, cytokine, and cortisol research is too limited to suggest that sweat is a useful surrogate for blood. Conclusion: Final sweat composition is not only influenced by extracellular solute concentrations, but also mechanisms of secretion and/or reabsorption, sweat flow rate, byproducts of sweat gland metabolism, skin surface contamination, and sebum secretions, among other factors related to methodology. Future research that accounts for these confounding factors is needed to address the existing gaps in the literature.
Overview
CoChat Summary
TL;DR
This narrative review concludes that final eccrine sweat composition is shaped not only by extracellular solute concentrations but also by glandular secretion/reabsorption, sweat flow rate, gland metabolism, skin contamination, and sebum, so sweat is not generally a reliable proxy for blood. Elevated sweat sodium and chloride remain useful for cystic fibrosis screening, but most other sweat constituents lack established blood correlations or diagnostic utility.
Key findings
- Na+ and Cl− are the most concentrated sweat electrolytes, ranging from ~10 to ~90 mmol/L; their secretion/reabsorption mechanisms are well established, but mechanisms for most other sweat solutes remain equivocal.
- Sweat-blood correlations have not been established for most constituents, with perhaps the exception of ethanol; sweat glucose is ~100× lower than blood glucose, and glucose, cytokine, and cortisol research is too limited to support sweat as a blood surrogate.
- Sweat electrolyte concentrations are not predictive of hydration status or sweating rate, and sweat metabolite concentrations are not reliable biomarkers of exercise intensity or other physiological stressors.
- Heat acclimation can decrease sweat [Na+] and [Cl−] by up to 30–60% after 7–10 days; within a bout, as forearm sweating rate increased from ~0.25 to 0.82 mg/cm2/min, sweat [Na+] rose from 19 ± 5 to 59 ± 10 mmol/L, with Na+ reabsorption falling from 86 ± 3% to 65 ± 6%.
Methods
- Narrative review of physiological mechanisms determining eccrine sweat composition during passive and active heat stress.
- Covers major electrolytes (Na+, Cl−, K+), other micronutrients (Ca2+, Mg2+, Fe2+, Cu2+, Zn2+, vitamins), metabolites (glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), cytokines, and cortisol.
- Synthesizes literature on secretion/reabsorption, collection and analytical confounders, heat acclimation/diet/training effects, and sweat-versus-blood correlations, including Table 1 ranges and supplemental tables.
Limitations
- Stated: mechanisms of secretion/reabsorption for most non-Na/Cl solutes are still equivocal; few well-designed, adequately powered sweat-blood correlation studies exist; methodological confounds include skin surface contamination, collection method, storage, and analytical technique; normative data are insufficient for most constituents; no longitudinal training studies and no sweat-blood cortisol comparisons are available.
- Evident from the text: as a narrative review, it does not use a systematic search or meta-analysis, and many cited studies are old, small, or report mixed/equivocal results, with the authors repeatedly calling for more controlled research.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
76 Valid · 13 Not valid · 213 Not checked · 79 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“some in vitro experiments suggest that ion channel (ENaC) activity is temperature dependent, such that higher temperature increases excitability and open probability”
§ Physiological mechanisms determining eccrine sweat composition > Mechanisms determining sweat composition > Electrolytes (sodium, chloride, and potassium)
What the sources say
- Disputedcites Chraibi and Horisberger 2002 matched to “Na Self Inhibition of Human Epithelial Na Channel” (2002) sourceExperimental — accuracy not yet measured
The Results section (‘Effect of Temperature on the Steady-State Amiloride-sensitive Current’) reports that, under control conditions, ENaC current decreased as temperature rose; it increased only after protease treatment. The Discussion (‘Effect of Temperature and Kinetics of Self Inhibition’) says high temperature favors the low-open-probability state, contrary to the claimed increase in open probability. (LLM, conf=0.90)
Checked by a reasoning model — may be wrong.
- Disputedcites Chraibi and Horisberger 2003 matched to “Dual effect of temperature on the human epithelial Na + channel” (2003) sourceExperimental — accuracy not yet measured
The Discussion (p. 5) reports that ENaC open probability increased 2.3-fold on cooling, contrary to the claim that higher temperature increases it. The paper does report greater unitary current at higher temperature, but that is distinct from open probability; it does not establish increased excitability. (LLM, conf=0.89)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites Ruff 1999 matched to “Effects of temperature on slow and fast inactivation of rat skeletal muscle Na+channels” (1999) source
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“There is no experimental evidence that alcohol ingestion leads to an increase in sweating rate (Baker 2019).”
§ Physiological mechanisms determining eccrine sweat composition > Mechanisms determining sweat composition > Metabolites
What the sources say
- Disputedcites Baker 2019 matched to “Physiology of sweat gland function: The roles of sweating and sweat composition in human health” (2019) sourceExperimental — accuracy not yet measured
In “Excretion of ethanol,” Baker reports that one laboratory study found a higher chest sweating rate 10–30 minutes after alcohol ingestion than after water. The increase was small and transient, and other studies found no difference, but the reported experiment contradicts the claim that there is no experimental evidence of an increase. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Since extracellular fluid is the precursor to primary sweat in the secretory coil of eccrine sweat glands (Cage and Dobson 1965; Sato 1977)”
§ Physiological mechanisms determining eccrine sweat composition > Introduction
What the sources say
- Supportedcites Cage and Dobson 1965 matched to “Sodium Secretion and Reabsorption in the Human Eccrine Sweat Gland*” (1965) source
The Discussion states that the precursor of the secretory fluid must be interstitial fluid or blood plasma, both extracellular fluids. The paper also describes the secretory fluid as being produced in the secretory coil. (LLM, conf=0.93)
- Not checked — no full text of the sourcecites Sato 1977 matched to “The physiology, pharmacology, and biochemistry of the eccrine sweat gland” (1977) source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“its application has been limited to date (Brothers et al. 2019; Gao et al. 2018; Heikenfeld et al. 2018).”
§ Physiological mechanisms determining eccrine sweat composition > Introduction
What the sources say
- Not checked — no full text of the sourcecites Brothers et al. 2019 matched to “Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms” (2019) source
- Supportedcites Gao et al. 2018 matched to “Wearable physiological systems and technologies for metabolic monitoring” (2018) source
The ‘Effects of environment on measuring sweat’ section says wearable sweat-monitoring devices existed as research prototypes but were not yet commercially available. It also describes practical barriers to their use, supporting the claim that application had been limited to date. No page number is provided in our copy. (LLM, conf=0.90)
- Supportedcites Heikenfeld et al. 2018 matched to “Wearable sensors: modalities, challenges, and prospects” (2018) source
The Wearable Chemical Sensors section reports demonstrations of non-invasive, real-time sweat monitoring but says that no commercial wearable products for sweat-based chemical detection yet exist. Its discussion of unresolved sampling and validation challenges supports the claim that practical application remained limited; the passage has no page number in our copy. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Whole body sweating rate can be > 3.0 L/h (Armstrong et al. 1986; Barnes et al. 2019; Bergeron 2003; Godek et al. 2005, 2010; Palmer and Spriet 2008).”
§ Physiological mechanisms determining eccrine sweat composition > Eccrine sweat glands and thermoregulatory sweating
What the sources say
- Not checked — no full text of the sourcecites Armstrong et al. 1986 matched to “Preparing Alberto Salazar for the Heat of the 1984 Olympic Marathon” (1986) source
- Partly supportedcites Barnes et al. 2019 matched to “Normative data for sweating rate, sweat sodium concentration, and sweat sodium loss in athletes: An update and analysis by sport” (2019) sourceExperimental — accuracy not yet measured
Our copy of Barnes et al. (2019) repeatedly documents whole-body sweating rate (WBSR) in athletes and 'considerable overall inter-individual variation in sweating' (Conclusion; Discussion, p. n/a), with the highest sport means in American football (1.51 ± 0.70 L/h) and endurance (1.28 ± 0.57 L/h) (ABSTRACT; Table 3). However, no passage states that WBSR can exceed 3.0 L/h; the only explicit high-rate threshold given is that 'three of the 24 endurance athletes tested outdoors had sweating rates over 2.0 L/h' (Results, descriptive statistics), and the '>3–4' figure in the Introduction refers to grams of Na+ loss, not sweating rate. The range/maximum values that could carry the >3.0 L/h magnitude sit in Tables 2–3, which are not rendered in our copy (placeholder rows only). So the source supports high and highly variable WBSR in athletes but not the specific >3.0 L/h magnitude attributed to it. (LLM, conf=0.68)
- Not checked — no full text of the sourcecites Bergeron 2003 matched to “Heat cramps: fluid and electrolyte challenges during tennis in the heat” (2003) source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
257 more claims · 59 with their cited sources checked
Create a free account to see all 381 claims and to verify the 11 references still open.
- Probably not a substantial claim. 40
- It may state two separate claims as one. 90
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Physiological mechanisms determining eccrine sweat composition > Overview of sweat composition
“| Amino Acids | R–CH(NH2) –COOH | ≤ 13 × 10–3 each | ≤ 6.5 × 10–3 each | 75–204 each | Polar and nonpolar | Leaching of natural moisturizing factors from the skin | NA |”
§ Physiological mechanisms determining eccrine sweat composition > Effects of heat acclimation, diet, and physical training on sweat composition > Metabolites
“total amino acid concentrations in sweat were significantly lower in trained (physically active for an average of 9 h per week) than untrained (average of 1 h of sports per week) men during 15 min of cycling at 150 W while covered with a plastic blanket (12,797 vs. 24,855 µmol/L, respectively).”
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
American College of Sports Medicine position stand
Otis, C. L. (1997) · Medical Entomology and Zoology · Cited by 4,407
Webb, A. K. (2006) · Cited by 4,369
Cytokines, Inflammation, and Pain
Zhang, J.-M., & An, J. (2007) · International Anesthesiology Clinics · doi:10.1097/aia.0b013e318034194e · Cited by 2,945
USSING, H. H., & ZERAHN, K. (1951) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1951.tb00800.x · Cited by 2,406
Adaptations of skeletal muscle to endurance exercise and their metabolic consequences
Holloszy, J. O., & Coyle, E. F. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.4.831 · Cited by 1,985
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Salivary Cortisol in Psychobiological Research: An Overview
Kirschbaum, C., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000118611 · Cited by 1,532
Exercise and Fluid Replacement
(2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802ca597 · Cited by 1,497
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · cited 2×
“, pilocarpine or methacholine) transdermally to stimulate the muscarinic receptors on the sweat glands (Gibson and Cooke 1959; Webster 1983).”
Background
Research works printed but not linked: 9
- Brunner H Über Glykogen in der gesunden und kranken Haut Verh Dtsch derm Gesellschaft 1906 9 521 535
- Embden R Tachau H Uber das Vorkommen von Serin im menschlichen Schweisse Biochem Ztschr 1910 28 230
- Kirschbaum C Hellhammer DH Fink G Salivary cortisol Encyclopedia of stress 2000 2 New York Academic 405 409
- Kuno Y Human perspiration 1956 Springfield Charles C. Thomas Publisher
- Kutchai HC Berne RM Levy MN Cellular membranes and transmembrane transport of solute and water Physiology 1998 St. Louis Mosby Press 3 20
- Ladell WSS Shephard RJ Aldosterone inhibition and acclimatization to heat Proc Physiol Soc 1961 3–4 19P 20P
- Sato K Gisolfi CV Nadel ER The mechanism of eccrine sweat secretion Exercise, heat, and thermoregulation Perspectives in exercise science and sports medicine 1993 Dubuque Brown & Benchmark 85 117
- Wescor Sweat Chek™ sweat conductivity analyzer model 3120 instruction/service manual 2005 USA Wescor Inc
- Yuyama H On the histological examination of distribution of glycogen in the skin of leprosy with special reference to the relationship between the function of sweat glands and the changes of glycogen content J Derm Urol 1935 37 811 832
Cited by
Items 301–348 of 348
Montiel-Nelson, J. A., Ottella, M., & Azzoni, P. (2025) · Design, Automation, and Test in Europe · doi:10.23919/date64628.2025.10993023 · Cited by 1
“Likewise, pH, C-reactive protein, lactate and cortisol are analytes present on the skin and excreted in sweat that may be detected and evaluated for diagnostic purposes [11].”
Phenotypic diversity of cystic fibrosis:pathogenesis and modifying factors
Mokrousova, D., Efremova, A. S., Kashirskaya, N. Y., Хавкин, А. И., & Goldshtein, D. V. (2025) · Экспериментальная и клиническая гастроэнтерология · doi:10.31146/1682-8658-ecg-233-1-125-136 · Cited by 1
Zhang, Y., van Santen, H. M., Musson, R. E. A., Markopoulos, P., & Lu, Y. (2025) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2025.100850 · Cited by 1
An Enzyme‐Composite Sweat Sensor for the Detection of Multiplexed Diabetic Nephropathy Biomarkers
Liu, C., Zhao, H., Mugo, S. M., Wang, H., Sun, Y., & Zhang, Q. M. (2025) · Advanced Sustainable Systems · doi:10.1002/adsu.202501068 · Cited by 2
Zhang, Z., Addokhi, A., Hughes, K. A., Zang, H., Piqueras, M. D. C., Kuzmanović, U., Charles, R., Leung, L., Klapperich, C. M., Allen, K. N., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.10.31.685570
Levent, S., Elriş, A., Özcan, S., & Can, N. Ö. (2026) · International Journal of Analytical Chemistry · doi:10.1155/ianc/6649147 · Cited by 1
“As a diagnostic and detection fuid, it has many advantages over other biological fuids [17].”
Design and Implementation of a Wearable Electrochemical Sweat Sensing Platform on Smart Eyeglasses
Acar, M. A., & Carminati, M. (2025) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine66377.2025.11340080
A deep learning strategy to estimate the sweat rate per gland from digital sweat sensing
Haakma, J. R., Turco, S., Esselaar, E., Mischi, M., & Peri, E. (2026) · Discover Sensors · doi:10.1007/s44397-026-00040-6
“The composition of sweat, including the concentrations of its biomarkers, depends on the sweat rate per gland [1, 9–11].”
Aerosol Jet and 3D Printed Impedance-Based Wearable Sensors for Local Sweating Rate MonitoringPreprint
Dong, K., Wen, H., feiyang, H., et al. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6208399
Can We Protect Our Hearts by Sweating Out Excess Sodium?
Hoch, J. W., & Watso, J. C. (2026) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000383
Jin, Q., Wu, W., Wu, W., Zhang, H., Zhang, J. J., Chang, S., Zhou, J., Zhou, Q., & Hu, M. (2026) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2026.151354
Dual-mode paper-based epidermal microfluidics for sweat rate normalized chloride sensing
Keyvanara, M., Parvaneh, S., Dehghani, P., Bahramian, A., & Golparvar, A. J. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140686 · Cited by 1
Strategies for latent fingermark development using metal organic frameworks
Sun, L., Liu, L., Zhao, Y., & Tong, Z. (2026) · Talanta · doi:10.1016/j.talanta.2026.130027
Aerosol jet and 3D printed impedance-based wearable sensors for local sweating rate monitoring
Dong, K., Wen, H., Huang, F., Gao, Z., Cao, Y., Xu, X., Ye, Q., & Liu, Q. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118496
Reliability and validity of portable sweat sodium analyzers during exercise in the heat
Zhao, X., McKenna, Z., Wierick, S. C., Perez, R. I., Sellner, R. S., Allen, B., & McDermott, B. P. (2026) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2025-0482 · Cited by 2
Pan, Y., Huang, J., Chen, Z., Zhang, Z., Vasić, Ž. L., Cifrek, M., 刘爱林, & Gao, Y. (2026) · Talanta · doi:10.1016/j.talanta.2026.130080 · Cited by 1
Exercise-induced sweat suppresses depression-like behaviors in micePreprint
Yao, H., Xing, S., Liang, M., Fei, Q., Cao, J., Liang, T., Yang, B., Cui, C., Liu, H., & Cui, Q. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.02.728455
Liu, H., & Lin, W. (2026) · Analytical Methods · doi:10.1039/d6ay00936k
Duan, J., Yin, X., He, B.-C., Liu, Y., & Zhang, Y. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118712
Zeng, Y., Wang, X., Li, L., wang, Y., Li, S., Liu, S., Liao, X., Zhang, M., & Liu, R. (2026) · Materials Research Bulletin · doi:10.1016/j.materresbull.2026.114297
Gao, J., Kim, J., Ross, C. K., Sun, X., Fan, S., Liu, Y., Guo, B., & Xu, J. (2026) · ACS Sensors · doi:10.1021/acssensors.6c00495
Electrodermal Activity as a Predictor of Emergence Time from General Anaesthesia
Zinca, R.-G., Adochiei, I.-R., Argatu, F.-C., Dolhascu, D. A., Nidelea, M., & Adochiei, F. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-24045-3_56
Xu, J. Q., Xing, H., Jin, Z., & Cho, Y. (2026) · RSC Applied Interfaces · doi:10.1039/d6lf00169f
A Comparative Study of MALDI MSI Versus DESI MSI Applied to Questioned Document Examination
Tibljas, V., Francese, S., Abreu, M. C. D. C., et al. (2026) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.70135
“In cases where the ions originate from printed inks, this enhancement could be attributed to improved co-crystallisation and enhanced positive charge transfer arising from salts present in sweat [36].”
Ion-exchange gold nanopore membranes for potentiometric “total ion concentration” sensing
Solymosi, G. T., Karácsony, R. Z., & Gyurcsányi, R. E. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140482
The role of sweat chloride in determining CFTR protein restoration in people with cystic fibrosis
Zemanick, E. T., Graeber, S. Y., Castellani, C., Cutting, G. R., Fajac, I., Konstan, M. W., Linnemann, R. W., McKone, E. F., Metcalf, A., Solomon, G. M., et al. (2026) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(26)00159-1
Evaluation of pilocarpine effects on sweat proteome
Wislet, S., Goff, C. L., Massonnet, P., Hody, S., Croisier, J. L., D'Orio, V., Kaux, J., Mazzucchelli, G., & Cloots, R. (2026) · Journal of Proteomics · doi:10.1016/j.jprot.2026.105709
Noninvasive measurement of glucose and lactate in thermoregulatory sweat in neonates and adults
Liu, X., Gowers, S. A. N., Gourin, B., McClure, Z. E., Dado, S., Abraham, T., Banerjee, J., & Boutelle, M. G. (2026) · Science Advances · doi:10.1126/sciadv.aec4166 · Cited by 2
“This is supported by other studies in the literature, which suggest that lactate measurements may reflect local lactate production by the sweat gland itself ( 15 , 40 , 41 ).”
Model-Driven Discovery of Highly Sensitive Nanocolumnar NiO Electrochemical Glucose Sensors
Bigdeli, M. M., Bruce, J., Jemere, A. B., Harris, K. D., & Stroberg, W. (2026) · ACS Engineering Au · doi:10.1021/acsengineeringau.6c00026 · Cited by 1
Effects of tattoos on sweating and thermoregulation during exercise: a systematic review
Segura, J. M., Sepulveda, R. A. Y., Cortés-Roco, G., Rojas-Campos, L., Poltronieri, S. A. M., Rojas‐Valverde, D., & Becerra-Patiño, B. A. (2026) · Sport Sciences for Health · doi:10.1007/s11332-026-01868-6
“During exercise, the sympathetic nervous system, via acetylcholine release, activates eccrine sweat glands distributed across the body's surface, increasing sweat production to dissipate heat generated by muscle metabolism [4, 35].”
Miao, F., Wang, H., & Tao, B. (2026) · Microchimica Acta · doi:10.1007/s00604-026-08309-8
Applications of Wearable Sweat Biosensors in Sports Activities with Real-World Cases
Yan, J., Shi, J., Zhang, Z., Yang, M., Zhang, M., & Wang, M. (2026) · Bioengineering · doi:10.3390/bioengineering13080906
“…mmol/L in blood during intense exercise, primarily because sweat lactate is largely produced locally by eccrine gland metabolism, where blood glucose is converted into lactate via glycolysis within the gland itself, rather than arising from the direct filtration or clearance of blood lactate [30].”
Extended Gate Organic Electrochemical Transistor for Sweat Lactate Detection in Hemorrhagic Shock
Nuro, J., Opoku, J. N. K., Pali, M. L., Inam, A. K. M. S., & Tabassum, S. (2026) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps69128.2026.11645068
Maximo, R. T., da Silva, M. G. N. M., Martins, D. B. G., Cavalcante, P. S., Tedesco, P., Belian, R. B., & Yara, R. (2026) · Scientific Electronic Archives · doi:10.36560/19520262251
“For most constituents, sweat–blood relationships have either not yet been established or have yielded conflicting results (Baker & Wolfe, 2020).”
Mori, K., & Tsunoda, M. (2026) · Talanta · doi:10.1016/j.talanta.2026.130480
Chen, X., Lyu, M., Wang, H., et al. (2026) · Sustainable Chemistry for Energy Materials · doi:10.1016/j.scenem.2026.100056
Wierick, S. C., McKenna, Z. J., Perez, R. I., Zhao, X., Sellner, R. S., Allen, B. M., & McDermott, B. P. (2026) · European Journal of Applied Physiology · doi:10.1007/s00421-026-06409-0
A preliminary multimodal forensic assessment of footpad skin in a rat model of fatal heatstroke
Liu, H., Pan, M., Ma, C., Sun, C., Zhu, W., & Dong, H. (2026) · Legal Medicine · doi:10.1016/j.legalmed.2026.102981
Painless Biosensing for Non‐Invasive Health Monitoring: Advances, Platforms and Future Directions
Alam, A., Gull, F., Hameed, M., Iqbal, I., Naz, S., Noor, H., Aslam, A., Younis, S., Vit, V., Mehmood, M. A., et al. (2026) · Electrochemical Science Advances · doi:10.1002/elsa.70041
Multiplex ovarian hormone monitoring in sweat using a dual-aptamer wearable sensor
Lee, Y. S., Ye, C., Yeom, J., Chen, Y., Li, J., Min, J., Wang, M., & Gao, W. F. (2026) · Device · doi:10.1016/j.device.2026.101299
“Resting thermoregulatory sweat is slowly secreted and acidic (pH ∼ 4.5–5.5) owing to extensive ductal bicarbonate reabsorption, 32 whereas exercise-induced sweat produced at higher Article ll flow rates is closer to neutral (pH ∼ 5.5–7.0) and contains elevated electrolyte concentrations that scale…”
InfluentialResearch progress in microneedle-based electrochemical sensing for health monitoring
Zhao, Y., Cheng, X., Fan, Z., Mu, L., Li, H., Song, S., Li, Z., Jeerapan, I., & Zhu, Z. (2026) · Biomedical Instrumentation · doi:10.1016/j.bmi.2026.100070 · Cited by 1
Research Progress on Wearable Devices for Sweat Potassium Monitoring in Heart Failure Management
张, 晨. (2026) · Advances in Clinical Medicine · doi:10.12677/acm.2026.1693212
Ti3C2T x MXene-Enhanced Paper-Based Ion-Selective Electrodes for Sweat Sodium Monitoring
Cimmino, W., Zahed, M. A., Spinelli, M., Amoresano, A., Jung, J., Vitale, F., & Cinti, S. (2026) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.6c00137
Qi, Q., Duan, J., Lei, Y., Zhou, S., Liu, Q. S., Wang, Q., Gao, N., Sun, W., Zhan, Z., & Wu, Y. (2026) · Biosensors · doi:10.3390/bios16090523
“During exercise, sweat electrolyte dynamics provide one of the few noninvasive windows into fluid and electrolyte regulation at the skin surface [1,2].”
Salt- and Temperature-Responsive Poly(ethyleneimine)/Phenylthioacetic Acid Ion-Pair Assemblies
Hwang, J. S., Long, W., & Kim, J. (2026) · Digest Journal of Nanomaterials and Biostructures · doi:10.31083/djnb52488
Wearable sweat sensors for arthritis monitoring
Tiwari, A., Xu, B. B., & Zhang, X. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182747
Gotsmy, M., Brunmair, J., Büschl, C., Gerner, C., & Zanghellini, J. (2022) · Figshare · doi:10.6084/m9.figshare.21151115
Metadata
- Authors
- Baker, L. B., & Wolfe, A. S.
- Affiliations
- Gatorade Sports Science Institute (US)
- Corresponding author
- Baker, Lindsay B.
- ORCID
- Baker, Lindsay B.
- Venue
- European Journal of Applied Physiology
- Published
- 2020-03-02
- Volume
- 120
- Issue
- 4
- Pages
- 719-752
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- PMC
- PMC7125257
- OpenAlex
- W3010240226
- Semantic Scholar
- 3a7f3eeeee43ce9bbcb7b652fe248abe7d8d2ac5
- Cited by
- 367
- References
- 365
- Citations by year
- 2026: 85 · 2025: 76 · 2024: 66 · 2023: 53 · 2022: 40 · 2021: 34 · 2020: 10
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- European Journal of Applied Physiology (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Gatorade Sports Science Institute (NA)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- eccrine sweat, sweat composition, sweat electrolytes, sodium, chloride, potassium, sweat biomarkers, cystic fibrosis screening, cortisol, exercise intensity
- MeSH terms
- Acclimatization, Eccrine Glands, Electrolytes, Humans, Specimen Handling, Sweat, Sweating, Sodium Chloride, Dietary, Micronutrients, Physical Conditioning, Human
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.