Nanobiosensors: optofluidic, electrical and mechanical approaches to biomolecular detection at the nanoscale
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
One‐Dimensional Nanostructures: Synthesis, Characterization, and Applications
Xia, Y., Yang, P., Sun, Y., Wu, Y., Mayers, B., Gates, B., Yin, Y., Kim, F., & Yan, H. (2003) · Advanced Materials · doi:10.1002/adma.200390087 · Cited by 8,559 · cited 2×
“One-dimensional nanostructures (Xia et al. 2003; Lieber and Wang 2007), such as carbon nanotubes and semiconductor or polymer nanowires, represent an interesting and relatively new paradigm for biochemical sensing (Cui et al.”
BackgroundInfluentialSaleh, B. E. A., & Teich, M. C. (1991) · doi:10.1002/0471213748 · Cited by 3,383
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214 · cited 2×
“This problem was solved by Armani et al. (2003) who used a novel process to fabricate toroidal silica microresonators with a diameter of 120 lm on a chip.”
BackgroundMethodHaes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352 · cited 2×
“Such an approach was recently demonstrated by Stern et al. (2007) where nanowires were fabricated as part of a CMOS process using ultra-thin SOI wafers and enabled through a unique tetramethylammonium hydroxide wet etching procedure (traditional RIE type etches were observed to degrade sensing…”
MethodEnzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294 · cited 1×
“Likely the first NT-FET displaying real time biological and pH sensing capabilities was established by (Besteman et al. 2003) in which they were able to measure glucose oxidase activity by measuring changes in nanotube conductance.”
BackgroundEmerging molecular markers of cancer
Sidransky, D. (2002) · Nature Reviews Cancer · doi:10.1038/nrc755 · Cited by 662 · cited 2×
“…single biomarkers available for screening healthy populations for complex diseases remains relatively small (Ward et al. 2001; Hernandez and Thompson 2004) the potential for diagnosis based on panels of multiple biomarkers (Sidransky 2002; Wulfkuhle et al. 2003) presents an exciting possibility.”
Background
Cited by
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Prebiotic Systems Chemistry: New Perspectives for the Origins of Life
Ruiz-Mirazo, K., Briones, C., & de la Escosura, A. (2014) · Chemical Reviews · doi:10.1021/cr2004844 · Cited by 930
Integrated optical devices for lab‐on‐a‐chip biosensing applications
Estevez, M. C., Alvarez, M., & Lechuga, L. M. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100025 · Cited by 617
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
High quality factor photonic crystal nanobeam cavities
Deotare, P. B., McCutcheon, M. W., Frank, I. W., Khan, M., & Lončar, M. (2009) · Applied Physics Letters · doi:10.1063/1.3107263 · Cited by 513
Electrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Photonic Crystals in Bioassays
Zhao, Y., Zhao, X., & Gu, Z. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201000098 · Cited by 255
Puiu, M., & Bala, C. (2016) · Sensors · doi:10.3390/s16060870 · Cited by 225
Vora, L. K., Sabri, A. H., McKenna, P. E., Himawan, A., Hutton, A. R. J., Detamornrat, U., Paredes, A. J., Larrañeta, E., & Donnelly, R. F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00108-7 · Cited by 193
Biosensors in clinical chemistry — 2011 update
D'Orazio, P. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.06.025 · Cited by 186
“Limits of detection on the order of ng/cm 2 are possible with microfabricated structures [36] , with the possibility to further increase the sensitivity by reducing size of the structures to the nanoscale [37] .”
BackgroundA multiplexed optofluidic biomolecular sensor for low mass detection
Mandal, S., Goddard, J. M., & Erickson, D. (2009) · Lab on a Chip · doi:10.1039/b907826f · Cited by 159
Self-citation
Metadata
- Authors
- Erickson, D., Mandal, S., Yang, A. H. J., & Cordovez, B.
- Venue
- Microfluidics and Nanofluidics
- Published
- 2007-08-08
- Volume
- 4
- Issue
- 1-2
- Pages
- 33-52
- ISSN
- 1613-4982 (ISSN-L)
- 1613-4990
- OpenAlex
- W2159586092
- Cited by
- 242
- References
- 7
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.