Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.

Porous Implants Modulate Healing and Induce Shifts in Local Macrophage Polarization in the Foreign Body Reaction

Abstract

The foreign body reaction (FBR) to implanted materials is of critical importance when medical devices require biological integration and vascularization to support their proper function (e.g., transcutaneous devices, implanted drug delivery systems, tissue replacements, and sensors). One class of materials that improves FBR outcomes is made by sphere-templating, resulting in porous structures with uniform, interconnected 34 μm pores. With these materials we observe reduced fibrosis and increased vascularization. We hypothesized that improved healing is a result of a shift in macrophage polarization, often measured as the ratio of M1 pro-inflammatory cells to M2 pro-healing cells. In this study, macrophage polarity of 34 μm porous implants was compared to non-porous and 160 μm porous implants in subcutaneous mouse tissue. Immunohistochemistry revealed that macrophages in implant pores displayed a shift towards an M1 phenotype compared to externalized cells. Macrophages in 34 μm porous implants had up to 63% greater expression of M1 markers and up to 85% reduction in M2 marker expression (p < 0.05). Macrophages immediately outside the porous structure, in contrast, showed a significant enrichment in M2 phenotypic cells. This study supports a role for macrophage polarization in driving the FBR to implanted materials.

Overview

Integrity signals

Registry

Crossref · 10.1007/s10439-013-0933-0

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

3 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 58 references

Cited by

See all 416

Metadata

Authors
Sussman, E. M., Halpin, M. C., Muster, J., Moon, R. T., & Ratner, B. D.
Affiliations
  • University of Washington (US)
  • Howard Hughes Medical Institute (US)
Corresponding author
Ratner, Buddy D.
Venue
Annals of Biomedical Engineering
Published
2013-11-19
Volume
42
Issue
7
Pages
1508-1516
ISSN
  • 0090-6964 (ISSN-L)
  • 1573-9686
OpenAlex
W2022286567
Cited by
416
References
58
Citations by year
2026: 21 · 2025: 31 · 2024: 36 · 2023: 32 · 2022: 37 · 2021: 53 · 2020: 55 · 2019: 38 · 2018: 29 · 2017: 33 · 2016: 22 · 2015: 17 · 2014: 12
FWCI
16.75
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Howard Hughes Medical Institute
  • University of Washington
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Health Sciences › Medicine › Surgery › Wound Healing and Treatments
Keywords
foreign body reaction, porous implants, macrophage polarization, M1/M2 macrophages, pore size, fibrosis, vascularization, tissue repair, subcutaneous implantation, implant biocompatibility
MeSH terms
Animals, Foreign-Body Reaction, Macrophages, Wound Healing, Porosity, Prostheses and Implants, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Porous Implants Modulate Healing and Induce Shifts in Local Macrophage Polarization in the Foreign Body Reaction. https://app.cochat.ai/papers/10.1007/s10439-013-0933-0
The paper
Sussman, E. M., Halpin, M. C., Muster, J., Moon, R. T., & Ratner, B. D. (2014). Porous Implants Modulate Healing and Induce Shifts in Local Macrophage Polarization in the Foreign Body Reaction. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-013-0933-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.