Microfluidic platform for negative enrichment of circulating tumor cells
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Negative enrichment is the preferred approach for tumor cell isolation as it does not rely on biomarker expression. However, size-based negative enrichment methods suffer from well-known recovery/purity trade-off. Non-size based methods have a number of processing steps that lead to compounded cell loss due to extensive sample processing and handling which result in a low recovery efficiency. We present a method that performs negative enrichment in two steps from 2 ml of whole blood in a total assay processing time of 60 min. This negative enrichment method employs upstream immunomagnetic depletion to deplete CD45-positive WBCs followed by a microfabricated filter membrane to perform chemical-free RBC depletion and target cells isolation. Experiments of spiking two cell lines, MCF-7 and NCI-H1975, in the whole blood show an average of >90 % cell recovery over a range of spiked cell numbers. We also successfully recovered circulating tumor cells from 15 cancer patient samples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559 · cited 1×
“Epithelial Cell Adhesion Molecule (EpCAM) is a common surface marker for antibody based CTC isolation (Allard et al. 2004; Nagrath et al. 2007; Hoshino et al. 2011).”
BackgroundAllard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Isolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Riethdorf, S., Fritsche, H., Müller, V., Rau, T., Schindlbeck, C., Rack, B., Janni, W., Coith, C., Beck, K., Jänicke, F., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-1695 · Cited by 1,338
Circulating Tumor Cells: Liquid Biopsy of Cancer
Alix-Panabières, C., & Pantel, K. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.194258 · Cited by 1,134
Circulating tumor cells: approaches to isolation and characterization
Yu, M., Stott, S., Toner, M., Maheswaran, S., & Haber, D. A. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201010021 · Cited by 1,089 · cited 1×
“Current technologies for CTC isolation have been well-reviewed (Arya et al. 2013; Chen et al. 2012; Zhe et al. 2011; Yu et al. 2011; Sun et al. 2011; Gerges et al. 2010; Hou et al. 2010).”
BackgroundCirculating Tumor Cells in Patients with Breast Cancer Dormancy
Meng, S., Tripathy, D., Frenkel, E. P., Shete, S., Naftalis, E. Z., Huth, J. F., Beitsch, P. D., Leitch, M., Hoover, S., Euhus, D., et al. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1110 · Cited by 971
Circulating tumor cells (CTC) detection: Clinical impact and future directions
Paterlini-Brechot, P., & Benali, N. L. (2007) · Cancer Letters · doi:10.1016/j.canlet.2006.12.014 · Cited by 947 · cited 2×
“However, it has been noted that EpCAM-based method could significantly undercount the number of CTCs due to those cells that undergo Epithelial to Mesenchymal Transition (EMT) (Paterlini-Brechot and Benali 2007; Allard et al. 2004; Goeminne et al. 2000; Gorges et al. 2012).”
Detection and characterization of carcinoma cells in the blood
Racila, E., Euhus, D., Weiss, A. J., Rao, C., McConnell, J., Terstappen, L. W. M. M., & Uhr, J. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4589 · Cited by 712
Gorges, T. M., Tinhofer, I., Drosch, M., Röse, L., Zollner, T. M., Krahn, T., & von Ahsen, O. (2012) · BMC Cancer · doi:10.1186/1471-2407-12-178 · Cited by 565 · cited 2×
“However, it has been noted that EpCAM-based method could significantly undercount the number of CTCs due to those cells that undergo Epithelial to Mesenchymal Transition (EMT) (Paterlini-Brechot and Benali 2007; Allard et al. 2004; Goeminne et al. 2000; Gorges et al. 2012).”
A new device for rapid isolation by size and characterization of rare circulating tumor cells.
Desitter, I., Guerrouahen, B. S., Benali-Furet, N., Wechsler, J., Janne, P. A., Kuang, Y., Yanagita, M., Wang, L., Berkowitz, J. A., Distel, R. J., et al. (2011) · PubMed · Cited by 446
Microchip-based immunomagnetic detection of circulating tumor cells
Hoshino, K., Huang, Y.-Y., Lane, N., Huebschman, M., Uhr, J. W., Frenkel, E. P., & Zhang, X. (2011) · Lab on a Chip · doi:10.1039/c1lc20270g · Cited by 400
Gupta, V., Jafferji, I., Garza, M., Melnikova, V. O., Hasegawa, D. K., Pethig, R., & Davis, D. W. (2012) · Biomicrofluidics · doi:10.1063/1.4731647 · Cited by 383
Microdevice for the isolation and enumeration of cancer cells from blood
Tan, S. J., Yobas, L., Lee, G. Y. H., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9305-9 · Cited by 362 · cited 1×
“2008), deformability (Tan et al. 2009) and dielectric properties (Gupta et al.”
BackgroundConsiderations in the development of circulating tumor cell technology for clinical use
Parkinson, D. R., Dracopoli, N., Petty, B. G., Compton, C., Cristofanilli, M., Deisseroth, A., Hayes, D. F., Kapke, G., Kumar, P., Lee, J. S., et al. (2012) · Journal of Translational Medicine · doi:10.1186/1479-5876-10-138 · Cited by 323
High-throughput size-based rare cell enrichment using microscale vortices
Hur, S. C., Mach, A. J., & Di Carlo, D. (2011) · Biomicrofluidics · doi:10.1063/1.3576780 · Cited by 317 · cited 1×
“In recent years, hydrodynamic sorting has also been employed to isolate CTCs from patients sample (Hur et al. 2011; Sun et al. 2013).”
MethodFluid biopsy in patients with metastatic prostate, pancreatic and breast cancers
Marrinucci, D., Bethel, K., Kolatkar, A., Luttgen, M. S., Malchiodi, M., Baehring, F., Voigt, K., Lazar, D., Nieva, J., Bazhenova, L., et al. (2012) · Physical Biology · doi:10.1088/1478-3975/9/1/016003 · Cited by 302
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301 · cited 1×
“Current technologies for CTC isolation have been well-reviewed (Arya et al. 2013; Chen et al. 2012; Zhe et al. 2011; Yu et al. 2011; Sun et al. 2011; Gerges et al. 2010; Hou et al. 2010).”
BackgroundKasimir-Bauer, S., Hoffmann, O., Wallwiener, D., Kimmig, R., & Fehm, T. (2012) · Breast Cancer Research · doi:10.1186/bcr3099 · Cited by 284 · cited 1×
“But the fact that CellSearch failed to detect CTCs in 36 % of metastatic breast cancer patients (Kasimir-Bauer et al. 2012) raises the concern: when a certain patient is deemed CTC-negative, is it due to the true CTC-negative status of the patient or a limitation of the technology? Thus, there is an urgent need to dev…”
BackgroundSilicon-based microfilters for whole blood cell separation
Ji, H. M., Samper, V., Chen, Y., Heng, C. K., Lim, T. M., & Yobas, L. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9131-x · Cited by 272
DETECTION OF DISSEMINATED TUMOR CELLS IN PERIPHERAL BLOOD
Zieglschmid, V., Hollmann, C., & Böcher, O. (2005) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360590913696 · Cited by 272
Selinummi, J., Seppälä, J., Yli-Harja, O., & Puhakka, J. A. (2005) · BioTechniques · doi:10.2144/000112018 · Cited by 263
Antibody-independent isolation of circulating tumor cells by continuous-flow dielectrophoresis
Shim, S., Stemke-Hale, K., Tsimberidou, A. M., Noshari, J., Anderson, T. E., & Gascoyne, P. R. C. (2013) · Biomicrofluidics · doi:10.1063/1.4774304 · Cited by 215
Tan, S. J., Lakshmi, R. L., Chen, P., Lim, W.-T., Yobas, L., & Lim, C. T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.054 · Cited by 203 · cited 4×
“A CTCwas defined as an object with the following criteria: (a) circular to oval morphology, (b) a visible nucleus (Hoechst positive), (c) negative staining for CD45, and (d) positive staining for Cytokeratin (Marrinucci et al. 2012; Tan et al. 2010).”
InfluentialYang, L., Lang, J. C., Balasubramanian, P., Jatana, K. R., Schuller, D., Agrawal, A., Zborowski, M., & Chalmers, J. J. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22066 · Cited by 200 · cited 3×
“But this approach involves multiple sample processing steps, including RBC lysis (Yang et al. 2009), centrifugation, and multiple cell washing and re-suspension.”
BackgroundMethodLara, O., Tong, X., Zborowski, M., & Chalmers, J. J. (2004) · Experimental Hematology · doi:10.1016/j.exphem.2004.07.007 · Cited by 199 · cited 2×
“Many currently developed negative depletion techniques involve multiple steps such as chemical RBC lysis and centrifugation that contribute to the risk of losing CTCs and adversely affect the cells of interest (Marrinucci et al. 2010; Park et al. 2012; Yang et al. 2009; Marrinucci et al. 2012; Cho et al. 2012; Tong et…”
BackgroundCharacterization of circulating tumor cell aggregates identified in patients with epithelial tumors
Cho, E. H., Wendel, M., Luttgen, M., Yoshioka, C., Marrinucci, D., Lazar, D., Schram, E., Nieva, J., Bazhenova, L., Morgan, A., et al. (2012) · Physical Biology · doi:10.1088/1478-3975/9/1/016001 · Cited by 198 · cited 1×
“Many currently developed negative depletion techniques involve multiple steps such as chemical RBC lysis and centrifugation that contribute to the risk of losing CTCs and adversely affect the cells of interest (Marrinucci et al. 2010; Park et al. 2012; Yang et al. 2009; Marrinucci et al. 2012; Cho et al. 2012; Tong et…”
BackgroundLim, L. S., Hu, M., Huang, M. C., Cheong, W. C., Gan, A. T. L., Looi, X. L., Leong, S. M., Koay, E. S.-C., & Li, M.-H. (2012) · Lab on a Chip · doi:10.1039/c2lc20750h · Cited by 187
Circulating tumor cells: advances in detection methods, biological issues, and clinical relevance
Sun, Y.-F., Yang, X.-R., Zhou, J., Qiu, S.-J., Fan, J., & Xu, Y. (2011) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-011-0988-y · Cited by 184 · cited 1×
“Current technologies for CTC isolation have been well-reviewed (Arya et al. 2013; Chen et al. 2012; Zhe et al. 2011; Yu et al. 2011; Sun et al. 2011; Gerges et al. 2010; Hou et al. 2010).”
BackgroundEnrichment, detection and clinical significance of circulating tumor cells
Arya, S. K., Lim, B., & Rahman, A. R. A. (2013) · Lab on a Chip · doi:10.1039/c3lc00009e · Cited by 168 · cited 1×
“Current technologies for CTC isolation have been well-reviewed (Arya et al. 2013; Chen et al. 2012; Zhe et al. 2011; Yu et al. 2011; Sun et al. 2011; Gerges et al. 2010; Hou et al. 2010).”
BackgroundSelf-citationHe, W., Kularatne, S. A., Kalli, K. R., Prendergast, F. G., Amato, R. J., Klee, G. G., Hartmann, L. C., & Low, P. S. (2008) · International Journal of Cancer · doi:10.1002/ijc.23717 · Cited by 151 · cited 1×
“2013), their difference in density (He et al. 2008), deformability (Tan et al.”
BackgroundXu, T., Lü, B., Tai, Y., & Goldkorn, A. (2010) · Cancer Research · doi:10.1158/0008-5472.can-10-0686 · Cited by 150
Size-based hydrodynamic rare tumor cell separation in curved microfluidic channels
Sun, J., Liu, C., Li, M., Wang, J., Xianyu, Y., Hu, G., & Jiang, X. (2013) · Biomicrofluidics · doi:10.1063/1.4774311 · Cited by 149 · cited 1×
“In recent years, hydrodynamic sorting has also been employed to isolate CTCs from patients sample (Hur et al. 2011; Sun et al. 2013).”
MethodCytomorphology of Circulating Colorectal Tumor Cells: A Small Case Series
Marrinucci, D., Bethel, K., Lazar, D., Fisher, J., Huynh, E., Clark, P., Bruce, R., Nieva, J., & Kuhn, P. (2010) · Journal of Oncology · doi:10.1155/2010/861341 · Cited by 124
Circulating tumor cells: finding the needle in the haystack.
Xu, Z., Cher, M. L., & Bonfil, R. D. (2011) · Europe PMC (PubMed Central) · Cited by 122
Kahn, H. J., Presta, A., Yang, L., Blondal, J. A., Trudeau, M., Lickley, L. A., Holloway, C. M. B., McCready, D. R., Maclean, D., & Marks, A. (2004) · Breast Cancer Research and Treatment · doi:10.1023/b:brea.0000036897.92513.72 · Cited by 121
Park, J.-M., Lee, J.-Y., Lee, J.-G., Jeong, H., Oh, J.-M., Kim, Y. J., Park, D., Kim, M. S., Lee, H. J., Oh, J. H., et al. (2012) · Analytical Chemistry · doi:10.1021/ac3011704 · Cited by 120
Rolle, A., Günzel, R., Pachmann, U. A., Willen, B., Höffken, K., & Pachmann, K. (2005) · World Journal of Surgical Oncology · doi:10.1186/1477-7819-3-18 · Cited by 118
New technologies for the detection of circulating tumour cells
Gerges, N., Rak, J., & Jabado, N. (2010) · British Medical Bulletin · doi:10.1093/bmb/ldq011 · Cited by 114 · cited 1×
“Current technologies for CTC isolation have been well-reviewed (Arya et al. 2013; Chen et al. 2012; Zhe et al. 2011; Yu et al. 2011; Sun et al. 2011; Gerges et al. 2010; Hou et al. 2010).”
BackgroundRiethdorf, S., & Pantel, K. (2008) · Pathobiology · doi:10.1159/000123852 · Cited by 111 · cited 1×
“Our current understanding of clinical significance of CTCs is biased on the technology used (Riethdorf and Pantel 2008; Budd 2009).”
MethodEmerging Technologies for CTC Detection Based on Depletion of Normal Cells
Lustberg, M. B., Jatana, K. R., Zborowski, M., & Chalmers, J. J. (2012) · Recent results in cancer research/Recent Results in Cancer Research · doi:10.1007/978-3-642-28160-0_9 · Cited by 82 · cited 1×
“We had very little knowledge about the origin and significance of these cells and therefore we excluded these from CTC enumeration (Lustberg et al. 2012; Stott et al. 2010).”
BackgroundPitfalls in the detection of disseminated non-hematological tumor cells
Goeminne, J., Guillaume, T., & Symann, M. (2000) · Annals of Oncology · doi:10.1023/a:1008398228018 · Cited by 74
Tong, X., Yang, L., Lang, J. C., Zborowski, M., & Chalmers, J. J. (2007) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.20177 · Cited by 64 · cited 2×
“Many currently developed negative depletion techniques involve multiple steps such as chemical RBC lysis and centrifugation that contribute to the risk of losing CTCs and adversely affect the cells of interest (Marrinucci et al. 2010; Park et al. 2012; Yang et al. 2009; Marrinucci et al. 2012; Cho et al. 2012; Tong et…”
BackgroundCirculating Tumor Cells, Enumeration and Beyond
Hou, J., Krebs, M., Ward, T. H., Morris, K. L., Sloane, R. A. S., Blackhall, F. H., & Dive, C. (2010) · Cancers · doi:10.3390/cancers2021236 · Cited by 57
Optimal cellular preservation for high dimensional flow cytometric analysis of multicentre trials
Ng, A. A. P., Lee, B. T. K., Teo, T. S. Y., Poidinger, M., & Connolly, J. E. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.08.010 · Cited by 55
Lv, P., Tang, Z., Liang, X., Guo, M., & Han, R. P. S. (2013) · Biomicrofluidics · doi:10.1063/1.4808456 · Cited by 35 · cited 1×
“These include the bigger size of epithelial cells (Desitter et al. 2011; Lim et al. 2012; Xu et al. 2010; Lv et al. 2013), their difference in density (He et al.”
BackgroundCell loss in integrated microfluidic device
Zhu, L., Peh, X. L., Ji, H. M., Teo, C. Y., Feng, H. H., & Liu, W. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9085-z · Cited by 24 · cited 1×
“This design was chosen after comparing it with other micro filter designs for cell separation due to its unique advantages in retaining CTCs (Ji et al. 2008; Zhu et al. 2007; Sajay et al. 2012; Sajay et al. 2013).”
MethodBudd, G. T. (2009) · Molecular Pharmaceutics · doi:10.1021/mp900088r · Cited by 23
Towards an optimal and unbiased approach for tumor cell isolation
Gourikutty, S. B. N., Chang, C.-P., Cognart, H. A., Chung, W. C., Poenar, D. P., & Rahman, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9757-9 · Cited by 20 · cited 3×
“This design was chosen after comparing it with other micro filter designs for cell separation due to its unique advantages in retaining CTCs (Ji et al. 2008; Zhu et al. 2007; Sajay et al. 2012; Sajay et al. 2013).”
MethodSelf-citationTruett, A. A., Letizia, A. G., Malyangu, E., Sinyangwe, F., Morales, B. N., Crum, N. F., & Crowe, S. M. (2006) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/01.qai.0000191282.77954.fc · Cited by 14 · cited 1×
“Samples drawn had a cellular preservative (Ng et al. 2012; Truet et al. 2006) (Catlog#213358, Streck) manually added immediately after blood draw at a ratio of 1:1 and was maintained at 4 °C.”
MethodSmirnov, D. A., Merdek, K. D., Sprott, K. M., Skelley, A. M., Huang, R., Tenney, D., Jiang, C., Milutinovic, A., Tims, D., Dong, Y., et al. (2012) · Cancer Research · doi:10.1158/1538-7445.am2012-2389 · Cited by 6
Optimization Of Breast Tumor Cells Isolation Efficiency And Purity By Membrane Filtration
Sajay, B. N. G., Liu, Y., Chia-Pin, C., Poenar, D. P., & Rahman, A. R. A. (2012) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1073538 · Cited by 3
Self-citation
Cited by
Circulating tumor cells: biology and clinical significance
Lin, D., Shen, L., Luo, M., Zhang, K., Li, J., Yang, Q., Zhu, F., Zhou, D., Zheng, S., Chen, Y., et al. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00817-8 · Cited by 993
Current detection technologies for circulating tumor cells
Shen, Z., Wu, A., & Chen, X. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00803h · Cited by 433
Technologies for circulating tumor cell separation from whole blood
Bankó, P., Lee, S. Y., Nagygyörgy, V., Zrínyi, M., Chae, C. H., Cho, D. H., & Telekes, A. (2019) · Journal of Hematology & Oncology · doi:10.1186/s13045-019-0735-4 · Cited by 358
Lab on a chip for continuous-flow magnetic cell separation
Hejazian, M., Li, W., & Nguyen, N.-T. (2015) · Lab on a Chip · doi:10.1039/c4lc01422g · Cited by 347
Hybrid microfluidics combined with active and passive approaches for continuous cell separation
Yan, S., Zhang, J., Yuan, D., & Li, W. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600386 · Cited by 182
Metadata
- Authors
- Sajay, B. N. G., Chang, C.-P., Ahmad, H., Khuntontong, P., Wong, C. C., Wang, Z., Puiu, P. D., Soo, R., & Rahman, A. R. A.
- Affiliations
- Agency for Science, Technology and Research (SG)
- National University Hospital (SG)
- Corresponding author
- Chang, Chia-Pin
- Venue
- Biomedical Microdevices
- Published
- 2014-03-27
- Volume
- 16
- Issue
- 4
- Pages
- 537-548
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2086205304
- Cited by
- 56
- References
- 52
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 7 · 2021: 4 · 2020: 6 · 2019: 10 · 2018: 2 · 2017: 6 · 2016: 5 · 2015: 2 · 2014: 2
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Science and Engineering Research Council
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- circulating tumor cells, microfluidic cell separation, red blood cell depletion, whole blood processing, recovery factor, MCF-7 cells, NCI-H1975
- MeSH terms
- Cell Count, Cell Separation, Female, Filtration, Humans, Leukocytes, Male, Neoplastic Cells, Circulating, Microfluidics, Cell Line, Tumor, Microfluidic Analytical Techniques, Microtechnology, MCF-7 Cells, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.